• Title/Summary/Keyword: Detector

Search Result 6,223, Processing Time 0.028 seconds

Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology (감지기의 점검 기술향상을 위한 복합시험기의 개발)

  • Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

A Fast RSSI using Novel Logarithmic Gain Amplifiers for Wireless Communication

  • Lee, Sung-Ho;Song, Yong-Hoon;Nam, Sang-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.22-28
    • /
    • 2009
  • This paper presents a fast received signal strength indicator (RSSI) circuit for wireless communication application. The proposed circuit is developed using power detectors and an analog-to-digital converter to achieve a fast settling time. The power detector is consisted of a novel logarithmic variable gain amplifier (VGA), a peak detector, and a comparator in a closed loop. The VGA achieved a wide logarithmic gain range in a closed loop form for stable operation. For the peak detector, a fast settling time and small ripple are obtained using the orthogonal characteristics of quadrature signals. In $0.18-{\mu}m$ CMOS process, the RSSI value settles down in $20{\mu}s$ with power consumption of 20 mW, and the maximum ripple of the RSSI is 30 mV. The proposed RSSI circuit is fabricated with a personal handy-phone system transceiver. The active area is $0.8{\times}0.2\;mm^2$.

Motion Pattern Detection for Dynamic Facial Expression Understanding

  • Mizoguchi, Hiroshi;Hiramatsu, Seiyo;Hiraoka, Kazuyuki;Tanaka, Masaru;Shigehara, Takaomi;Mishima, Taketoshi
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1760-1763
    • /
    • 2002
  • In this paper the authors present their attempt io realize a motion pattern detector that finds specified sequence of image from input motion image. The detector is intended to be used for time-varying facial expression understanding. Needless to say, facial expression understanding by machine is crucial and enriches quality of human machine interaction. Among various facial expressions, like blinking, there must be such expressions that can not be recognized if input expression image is static. Still image of blinking can not be distinguished from sleeping. In this paper, the authors discuss implementation of their motion pattern detector and describe experiments using the detector. Experimental results confirm the feasibility of the idea behind the implemented detector.

  • PDF

Development and Implementation of Statistical Edge Detectors on the Web (웹 상에서 통계적 에지검출기 개발 및 구현)

  • Lim, Dong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.4 s.36
    • /
    • pp.133-141
    • /
    • 2005
  • An edge is where the intensity of an image moves from a low value to high value or vice versa. The edges tell where objects are. their shape and size. and something about their texture. Many traditional edge operators are derivative based and perform reasonably well for simple noise-free images. In recent, statistical edge detectors for complex images with noises have been described. This paper compares and analysis the performance of statistical edge detectors based on the T test and Wilcoxon test, and mathematical edge detectors based on Sobel operator, and the well-known Canny detector and Wavelet transformation detector, and provides the implementation of these edge detectors using Java on the web.

  • PDF

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

Multi-layer design of Hybrid method for digital X-ray imaging (디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계)

  • Cho, Sung-Ho;Park, Ji-Koon;Lee, Dong-Gil;Kim, Dae-Hwan;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

Feasibility Study of Data Acquisition System based on Oscilloscope for Radiation Detector (방사선 검출기용 데이터획득장치로서의 오실로스코프 활용 가능성 평가)

  • Yang, Jingyu;Kang, Jihoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.12
    • /
    • pp.1804-1809
    • /
    • 2017
  • A data acquisition (DAQ) system based on oscilloscope was developed and evaluated for radiation detector. The dedicated LabVIEW program that perform the oscilloscope control and the data process was developed. Triggered events for each analog channel were acquired and the output signals were subsequently digitized and recorded for offline processing. Radiation pulse generation circuit was developed to evaluate the intrinsic characteristics of DAQ system. Energy linearity and energy resolution performances were assessed by voltage-peak channels and FWHM obtained from Gaussian fit, respectively. Radiation detector consists of LYSO and GAPD array. The 16 output signals were multiplexed by the RCD networks, and they were fed into the custom-made preamplifiers. Voltage-peak channels was linearly changed as a function of input voltage and the estimated coefficient of determination ($R^2$) was 0.999. No considerable changes in voltage resolution were observed. All 16 crystals were clearly identifiable on the resulting flood image and the mean energy resolution was ~15.1%. This study demonstrated that it is feasible to develop the DAQ system based on oscilloscope and LabVIEW program for radiation detector and the proposed approach offers opportunities to build simple DAQ system in various radiation measurement field.

Design and Implementation of A effective Complex Fire Detector Module (효과적인 복합 소방 관제 모듈의 설계 및 구현)

  • Kong, Byung-Chul;Lee, Sun-Heum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1079-1084
    • /
    • 2010
  • Existing fire detector modules providing a simple fire alarm function have many drawbacks such as high installation, management and maintenance costs, and low scalability. In this paper, an add-on type complex fire detector module with high scalability and functions of examining the receiving units for fire sensors and itself has been developed, which enhances the reliability, stability, and economic feasibility of the existing fire detector modules. Information on when and where fire occurs, provided by the developed module, enables people to extinguish the fire immediately and minimize the damage of lives and property and also to systematically manage the fire-fighting related history and contribute to the prevention of fire.

Design and Implementation of an HTML Pages Modification Detector for Meta-search Engines (메타 검색엔진을 위한 HTML 문서 변경 탐지기의 설계 및 구현)

  • Park, Sang-Wi;O, Jeong-Seok;Lee, Sang-Ho
    • The KIPS Transactions:PartD
    • /
    • v.9D no.3
    • /
    • pp.345-354
    • /
    • 2002
  • HTML pages in the web change at any time. It could cause to decrease the functionality of meta-search engines which provide users with integrated results of search engines. To solve this problem, we propose an HTML pages modification detector. It utilities information of element positions in HTML pages and the modified Jaak Vilo algorithm. The HTML page modification detector uses patterns that represent the structure of HTML expressions occurring repeatedly in HTML pages. An experiment is carried out to verify the correctness of the modification detector.

A Study on the multcriteria Fuzzy Fire Detector (계층적 Fuzzy 감지기에 대한 연구)

  • 서영수;백동현
    • Fire Science and Engineering
    • /
    • v.11 no.2
    • /
    • pp.45-53
    • /
    • 1997
  • In this article, the Fuzzy Logic as the principle of the multcriteria fire detector is used to determine whether the fire takes out or not. The main contents of this method as follow; most of all, the degree of the fire is represented as the type of the Fuzzy, and then it is possible to examine whether the fire takes out or not by the principle of the Fuzzy Logic. The input fators of the Fuzzy fire detector are temperature sensor, smoke sensor, light sensor applied to digital type. On the result of this study, the first, the number of the case of the nonfire alarm which is represented in the existing fire detector is reduced, and the second, the applicability of the fuzzy detector is demonstrated by the test.

  • PDF