• 제목/요약/키워드: Dental internal fit

검색결과 68건 처리시간 0.024초

한국형 스케일링두려움 측정도구 개발(KSF-1.1) (Development of measurement scale for Korean scaling fear-1.1)

  • 조명숙;이승주
    • 한국치위생학회지
    • /
    • 제12권4호
    • /
    • pp.675-684
    • /
    • 2012
  • Objectives : The purpose of this study was to develop an instrument for Korean Scaling Fear (KSF)-1.1 in scaling patients. Methods : 402 sample size for scaling patients was studied in Daegu city in July and August of 2011. Mean and standard deviation was calculated in 3 dimensions(FWS: fear while scaling, DDH: distrust on dental hygienist, FAS: fear after scaling). Results : Age of 402 subjects was 36.5 years. In analyzing reliability for item-level, a range of correlation coefficient(${\alpha}$) on item-internal consistency(FWS, DDH, and FAS) was 0.58~0.88(${\alpha}$=0.90), 0.40~0.71(${\alpha}$=0.82), and 0.54~0.63(${\alpha}$=0.82), respectively. Floor(%) and ceiling(%) value on 3 dimensions were also 9.2% and 4.0%, 12.4% and 0.5%, and 17.7% and 1.2%, respectively, therefore, we found statistically high reliability for those(p<0.001). With explanatory factor analysis, this study could generate 3 dimensions(factor 1, eigenvalue 5.41, proportion 0.49; factor 2, eigenvalue 1.50, proportion 0.14; factor 3, eigenvalue 1.04, proportion 0.09) and 11 sub-scales. Also confirmatory factor analysis results showed that the KSF1.1 model was fitted very well in analysis of model fit($x^2$=112.94, df=41, p=0.000; goodness of fit index=0.95; adjusted goodness of fit index=0.92; root mean square residual=0.057). Conclusions : In conclusion, The findings of this study showed that developed reliable and valid instrument for measuring the KSF1.1 in the scaling patients.

Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems

  • Park, Jong-Kyoung;Lee, Wan-Sun;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권2호
    • /
    • pp.122-128
    • /
    • 2015
  • PURPOSE. To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (${\alpha}$=.05), respectively. RESULTS. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION. Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (< $120{\mu}m$). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.

밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향 (Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis)

  • 신미선
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교 (Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system)

  • 이완선
    • 구강회복응용과학지
    • /
    • 제40권2호
    • /
    • pp.72-81
    • /
    • 2024
  • 목적: 본 연구의 목적은 가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형을 이용해 치과용 캐드캠 시스템(CAD/CAM)으로 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내부 적합성을 평가하고자 하였다. 연구 재료 및 방법: 하악 우측 제1소구치와 하악 우측 제1대구치에 지르코니아 크라운을 위한 치아 삭제 프로토콜을 수행하고, 하악 우측 제2소구치가 없는 레퍼런스 모델을 만들었다. 레퍼런스 모델은 폴리비닐 실록산 인상체를 사용하여 복제되었고, 일반적인 치과 기공 절차에 따라 20개의 작업 모형이 제작되었다. 비교 분석을 위해, 10개의 지르코니아 3본 고정성 치과 보철물은 가철성 다이 시스템에서, 나머지 10개는 솔리드 작업 모형에서 제작되었다. 모든 작업 모형은 치과용 데스크탑 스캐너를 사용하여 디지털화되었고, 캐드 소프트웨어에서 보철물을 설계하였다. 최종 3본 고정성 치과 보철물은 밀링 과정을 통해 제작되었다. 변연 및 내부 적합도 평가는 레퍼런스 모델에 제작된 보철물을 위치시키고, 디지털 평가 방법으로 적합도가 측정되었다. 두 그룹 간의 통계 비교를 위해 Mann-Whitney U 검정이 적용되었다(α = 0.05). 결과: 가철성 다이 그룹은 솔리드 작업 모형 그룹에 비해 소구치와 대구치에서 유의하게 높은 적합도 차이를 보였으며(P < 0.05), 특히 변연 및 교합 간격에서 유의하게 높은 편차를 보였다. 색상 편차 맵에서도 가철성 다이 그룹이 변연 및 교합 영역에서 더욱 높은 편차를 보였다. 결론: 3본 고정성 치과 보철물의 적합도 차이는 가철성 다이 시스템의 작업 모형 상에서 제작된 치과 보철물에서 초래되었으며, 이를 통해 가철성 다이 제작 방법이 치과 고정성 보철물의 정확성에 영향이 있었음을 검증하였다.

Impact of surface roughness of gypsum materials on adaptation of zirconia cores

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Sa-Hak
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권3호
    • /
    • pp.199-206
    • /
    • 2015
  • PURPOSE. The present study investigated the influences of various gypsum materials on the precision of fit of CAD/CAM-fabricated prostheses and analyzed their correlation with surface roughness. MATERIALS AND METHODS. The master model of the mandibular right first molar was replicated, and four experimental groups based on two types of Type IV stone (GC Fujirock EP, Die keen) and two types of scannable stone (Aesthetic-Basegold, Everest Rock) were created to include a total of 40 specimens, 10 in each group. The surface roughness of the working models for the respective experimental groups was measured. Once the zirconia cores had been fabricated, the marginal and internal fits were measured with a digital microscope using the silicone replica technique. The mean and standard deviation of the respective points of measurement were computed and analyzed through the one-way ANOVA and Tukey's HSD test. The correlation between surface roughness and the precision of fit of the zirconia core was analyzed using the Pearson correlation analysis (${\alpha}$=.05). RESULTS. The zirconia cores fabricated from the scannable stone working models exhibited a superior precision of fit as compared to those fabricated from the Type IV stone working models. The correlation analysis results showed a clear positive correlation between surface roughness and the precision of fit of zirconia cores in all of the experimental groups (P<.05). CONCLUSION. The results confirmed that the surface roughness of dental working models has a decisive influence on the precision of fit of zirconia cores.

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

치과위생사의 직무만족에 관한 측정도구 개발 (Development of job satisfaction scale for dental hygienist)

  • 박지현;임순연
    • 한국치위생학회지
    • /
    • 제20권6호
    • /
    • pp.913-924
    • /
    • 2020
  • Objectives: This study was conducted to develop a dental hygienist's job satisfaction scale and to evaluate its validity and reliability. Methods: A total of 34 preliminary questions were composed based on the components commonly defined in previous studies and in-depth interviews. Results: The results of the study were practice activity, professional satisfaction, income, working conditions, patient relations, and co-worker relations using the exploratory factor analysis. Goodness of fit of the model assessed using confirmatory factor analysis generally met the criteria. On verification of the internal consistency, the Cronbach's alpha for the factors were as follows: 0.821 for practice activity, 0.822 for professional satisfaction, 0.847 for income, 0.765 for working condition, 0.743 for patient relations, and 0.747 for co-worker relations, which implied that the measurement tool was reliable. Through exploratory and confirmatory factor analyses, a total of 24 items for six factors: six items for practice activity factors, four items for professional satisfaction, three items for income, four items for working conditions, three items for patient relationships, and three items for coworker relations. Conclusions: Based on the aforementioned results, the validity and reliability of the dental hygienist's job satisfaction measurement tool were satisfactory. Thus, it may be used for assessing the job satisfaction of the dental hygienists in future.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권6호
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교 (Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns)

  • 고인석;김정미;조혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.226-233
    • /
    • 2016
  • 목적: 본 연구는 수복물의 적합도를 계측하는 두 가지 측정방법을 평가하기 위해 CAD-CAM (computer aided design-computer aided manufacturing)과 열가압 소성법으로 전부 도재관을 제작하고 micro CT와 cross-section technique으로 전부 도재관의 적합도를 비교하고자 하였다. 재료 및 방법: 하악 제 1대구치 레진 치아를 전부 도재관을 위한 지대치를 형성하고 PMMA (polymethylmethacrylate) 레진 블록을 가공하여 10개의 시편을 복제하였다. 복제한 레진 다이의 인상을 채득하고 모형을 제작하여 5개는 열가압 소성법으로 IPS e.max Press (Ivoclar Vivadent, Schaan, Liechtenstein) 도재관을 제작하였다. 다른 5개의 시편은 CAD-CAM 가공법(Ceramil motion 2, Amann Girrbach, Koblach, Austria)을 이용하여 IPS e.max CAD 도재관을 제작하였다. 각 레진 다이에 전부 도재관을 인산아연 시멘트(Fleck's zinc cement, Keystone industries, Gibbstown, NJ, USA)로 손가락 압력에 의해 합착하였다. 변연 및 내면 적합도를 측정하기 위해서 합착된 시편 10개를 먼저 micro CT로 촬영하여 협-설 시상면의 영상정보를 획득하였다. 그 후 절단 시편을 만들어 주사전자현미경으로 micro CT와 동일한 지점의 간극을 측정하였다. SPSS 22.0 프로그램을 이용하여 각 측정 지점에서 제작 방식별, 측정 방식별로 Mann-Whitney 검정 방법을 통해 유의차 검증을 시행하였다. 결과: Micro CT와 주사전자현미경으로 측정한 변연 및 내면 적합도는 유사하였으며, 통계적으로 유의한 차이를 보이지 않았다. 두 가지 제작법의 도재관은 변연 및 내면 적합도에 유의한 차이가 없었다. 결론: CAD-CAM과 열가압소성으로 제작한 전부 도재관은 적합도에 차이를 보이고 있지 않으며, Micro CT와 주사전자현미경을 이용한 측정 방식 모두 임상적으로 이용 가능할 것으로 사료된다.

CIPP 평가모형을 활용한 치위생과 교내임상실습 운영 평가기준 개발 (Development of evaluation criteria for dental hygiene intra-school clinical practice operation using CIPP evaluation model)

  • Jang, Mi-Hwa
    • 한국치위생학회지
    • /
    • 제22권2호
    • /
    • pp.93-105
    • /
    • 2022
  • 연구목적: 본 연구는 교내에서 실시하는 임상실습의 효율적인 운영을 위한 운영관리 평가기준을 개발하고 타당성과 신뢰성을 검증하였다. 연구방법: 본 연구의 평가기준 초안은 CIPP 프로그램 평가모형을 기반으로 도출하였으며, 내용의 타당성을 검증하기 위하여 5년 이상 임상실습 교육을 담당했던 치위생과 교수 및 임상현장 치과위생사 30명을 대상으로 델파이 조사를 실시하였으며, 실기교육을 담당하는 교수 및 임상현장 치과위생사 252명을 대상으로 본 조사를 실시하였다. 연구결과: 탐색적 요인분석을 통해 7개 요인으로 총 36문항을 확인하였으며 최종 평가 기준의 내적 일관성을 확인한 결과 내적 적합도는 0.914였다. 결론: 이상의 결과에 따라 교내 임상실습의 운영 및 관리를 평가하기 위한 평가기준의 타당성과 신뢰성이 적절함을 확인하였으며, 향후 이에 관련된 후속 연구에 활용될 수 있을 것으로 사료된다.