• Title/Summary/Keyword: Dental error

Search Result 191, Processing Time 0.028 seconds

Formulation of a reference coordinate system of three-dimensional head & neck images: Part II. Reproducibility of the horizontal reference plane and midsagittal plane (3차원 두부영상의 기준좌표계 설정을 위한 연구: II부 수평기준면과 정중시상면의 재현성)

  • Park, Jae-Woo;Kim, Nam-Kug;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.475-484
    • /
    • 2005
  • This study was performed to investigate the reproducibility of the horizontal and midsagittal planes, and to suggest a stable coordinate system for three-dimensional (3D) cephalometric analysis. Eighteen CT scans were taken and the coordinate system was established using 7 reference points marked by a volume model, with no more than 4 points on the same plane. The 3D landmarks were selected on V works (Cybermed Inc., Seoul, Korea), then exported to V surgery (Cybermed Inc., Seoul, Korea) to calculate the coordinate values. All the landmarks were taken twice with a lapse of 2 weeks. The horizontal and midsagittal planes were constructed and its reproducibility was evaluated. There was no significant difference in the reproducibility of the horizontal reference planes, But, FH planes were more reproducible than other horizontal planes. FH planes showed no difference between the planes constructed with 3 out of 4 points. The angle of intersection made by 2 FH planes, composed of both Po and one Or showed less than $1^{\circ}$ difference. This was identical when 2 FH planes were composed of both Or and one Po. But, the latter cases showed a significantly smaller error. The reproducibility of the midsagittal plane was reliable with an error range of 0.61 to $1.93^{\circ}$ except for 5 establishments (FMS-Nc, Na-Rh, Na-ANS, Rh-ANS, and FR-PNS). The 3D coordinate system may be constructed with 3 planes; the horizontal plane constructed by both Po and right Or; the midsagittal plane perpendicular to the horizontal plane, including the midpoint of the Foramen Spinosum and Nc; and the coronal plane perpendicular to the horizontal and midsagittal planes, including point clinoidale, or sella, or PNS.

An assessment of statistical errors of articles in the Journal of Korean Academy of Prosthodontics: Comparison between Korean version and English version (대한치과보철학회지에 게재된 논문의 통계적 오류: 국문논문과 영문논문의 비교)

  • Park, Dong-Gyu;Choi, Yong-Geun;Kim, Young-Su;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.273-285
    • /
    • 2009
  • Statement of problem: The aim of dental research is to advance scientific knowledge and leads to improvement in the treatment and prevention of dental disease. Utilizing an effective research design and adequate statistical methods are essential procedures ensuring that the results of researches are based on evidences. A research should utilize proper statistical methods without statistical errors; Otherwise, it could adversely affect clinical practice and future research. Purpose: This study was made to investigate the statistical methods used in the Journal of Korean Academy of Prosthodontics (JKAP) and then to assess them for the statistical errors. Material and methods: Among the total of 399 articles in the JKAP published from 2000 to 2006, 292 articles using statistics were reviewed. The validity of the statistical methods used in them were assessed using a checklist based on the guideline for statistical reporting in the uniform requirements for manuscripts submitted to biomedical journals by International Committee of Medical Journal Editors. The checklist consisted of three categories of statistical errors: 1) Unspecified computer statistical packages, 2) Inadequate description of statistical methods, 3) Misuse of statistical terms. Then, the results were compared between the Korean version and the English version in the JKAP. Results: Among the 212 articles using statistics in the Korean version, 115 articles (54%) and among the 80 articles using statistics in the English version, 47 articles (59%) were shown to have unspecified computer statistical packages without statistically significant difference (P = .66). Likewise, 101 articles (48%) in the Korean version and 25 articles (31%) in the English version were shown to have the inadequate description of statistical methods without statistically significant difference (P = .09). However, 114 articles (54%) in the Korean version and 19 articles (24%) in the English version were shown to have the misuse of statistical terms with statistically significant difference (P = .01). Conclusion: Some of the articles in the JKAP had inadequate statistical validity, given the statistical errors identified in this assessment. Hence, dental researchers should be more careful when it comes to describing and applying statistical methods.

A Study of the Relation of Stress to Oral Parafunctional Habits of Male High School Students (일부 지역 남자 고등학생들의 스트레스와 구강악습관과의 관련성 연구)

  • Jung, Yu Yeon;Hong, Jin Tae
    • Journal of dental hygiene science
    • /
    • v.13 no.4
    • /
    • pp.471-479
    • /
    • 2013
  • This study is trying to grasp the stress of the male high school students and the correlation between the stress according to the academic and economic level and oral parafunctional habits, emphasizing the need for the education of oral parafunctional habits, providing the basic data in order to accomplish correctly until the oral health of the oral maxillofacial region. From May 2013 till July 2013, a self administered survey was conducted by the selected by convenience sampling from subjects of 1, 2 grade of two high school located in Chungnam, Korea. The study results were as follow: 1) Among five areas of stress, the stress of school life was the highest as 2.11 points and the stress of home problem was the lowest as 1.51 points; 2) the stress by class showed that grade 2 was higher than grade 1 in all areas. The stress of the school life (2.21) (p<0.01), interpersonal relationship (p<0.01), and own problem (p<0.05) showed the significant difference; 3) The significance analysis results between the five areas of stress according to the stress of latent variable and the oral parafunctional habits all showed the significant difference (p<0.001). The correlation between the stress and the oral parafunctional habits showed a weak negative correlation as -0.30, and the stress of the school life, own problem, environment problem, and interpersonal relationship showed very strong correlations more than 0.7; 4) Fit measures test result of stress, academic level, and family economic level model all showed more than 0.9 in good of fit index, adjusted goodness of fit index, normed fit index and root mean square residual and root mean square error of approximation values is all estimated less than 0.1, so it showed good model. From this study, it can be concluded that there is the correlation between stress and oral parafunctional habits.

THE POSITIONING ERRORS IN BONDING LINGUAL BRACKETS (설측브라켓 부착시 위치오차에 관한 연구)

  • Choi, Joon-Kyu;Hwang, Hyeon-Shik;Kim, Jong-Chul
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.99-111
    • /
    • 1998
  • The purpose of this study was to evaluate the positioning errors according to the method of bonding lingual brackets. Dental models of twenty orthodontic patients with malocclusion were selected for this study. The positioning errors were measured on each model that brackets were bonded to. Three different bonding methods were used. For the first method the bracket was bonded intimately to the lingual surface of the model. For the second method, the bracket was bonded intimately to the lingual surface after setting up using articulator. The passive bracketing, bonding the bracket ligated first to ideal archwire, was used after setting up as the last method. The results were as follows: 1. The brackets bonded without setting up showed greater angulation errors in the upper 1st premolar and the lower canine than those in other bonding methods. The brackets bonded without passive bracketing showed greater positioning errors in upper central incisor, lower 1st and End premolars. 2. The brackets bonded without setting up showed greater torque error in lower 2nd premolar than those in other bonding methods. The brackets bonded without passive bracketing showed greater torque errors in all upper teeth, lower 1st and 2nd premolars. 3. The brackets bonded without passive bracketing showed greater rotation errors between upper central incisors, lower central incisors, lower lateral and central incisor, lower canine and lateral incisor. 4. The brackets bonded without setting up showed greater in-out errors between upper canine and lateral incisor than those in other bonding methods. The brackets bonded without passive bracketing showed greater in-out errors between upper central incisors, upper central and lateral incisors, upper 1st and 2nd premolars, lower lateral and central incisors, lower canine and lateral incisor. These results suggest that there is a large amount of positioning error in lingual brackets even by an indirect bonding technique, and it may be reduced by passive bracketing.

  • PDF

Comparative studies in Perception of Patient safety culture of Nurses and Dental hygienist (간호사와 치위생사의 환자안전문화 인식수준 비교연구)

  • Kim, Mi-Young;Kim, Young-Mi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5196-5205
    • /
    • 2012
  • Purpose: The Purpose of this study were to compare the level of perception and to identify factors associated with perception on patient safety culture by nurses and hygienists. Method: The data were collected from september to December, 2010 using Hospital survey on patient safety culture questionnaires. The subjects were 399 Nurses, hygienists, recruited from the hospital in Busan & Kyungnam. The collected data were analyzed using SPSS descriptive statistics, mean and standard deviation, t-test and ANOVA, Spearman rank coefficient. Result: The perception level of nurses on patient safety culture was 3.48. In case of hygienists, the level was 3.51. Compared to nurses, hygienists showed a significantly difference on the items "Staff arrangement"(t=2.841, p<.01) and "Administator attitude"(t=-2.471, p<.05), "Feedback and communication in accident"(t=-3.356, p<.01). Nurses and hygienists' age and career, working hour per week were identified as factor associated with patient safety culture. Conclusion: The perception level of hospital health providers on patient safety culture was moderate. and identified factors associated with patient safety culture were age and career, working hour per week.

Construction of a reference stature growth curve using spline function and prediction of final stature in Korean (스플라인 함수를 이용한 한국인 키 기준 성장 곡선 구성과 최종 키 예측 연구)

  • An, Hong-Sug;Lee, Shin-Jae
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.16-28
    • /
    • 2007
  • Objective: Evaluation of individual growth is important in orthodontics. The aim of this study was to develop a convenient software that can evaluate current growth status and predict further growth. Methods: Stature data of 2 to 20 year-old Koreans (4893 boys and 4987 girls) were extracted from a nationwide data. Age-sex-specific continuous functions describing percentile growth curves were constructed using natural cubic spline function (NCSF). Then, final stature prediction algorithm was developed and its validity was tested using longitudinal series of stature measurements on randomly selected 200 samples. Various accuracy measurements and analyses of errors between observed and predicted stature using NCSF growth curves were performed. Results: NCSF growth curves were shown to be excellent models in describing reference percentile stature growth curie over age. The prediction accuracy compared favorably with previous prediction models, even more accurate. The current prediction models gave more accurate results in girls than boys. Although the prediction accuracy was high, the error pattern of the validation data showed that in most cases, there were a lot of residuals with the same sign, suggestive of autocorrelation among them. Conclusion: More sophisticated growth prediction algorithm is warranted to enhance a more appropriate goodness of model fit for individual growth.

Accuracy and reliability of 2-dimensional photography versus 3-dimensional soft tissue imaging

  • Ayaz, Irem;Shaheen, Eman;Aly, Medhat;Shujaat, Sohaib;Gallo, Giulia;Coucke, Wim;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • Purpose: This study was conducted to objectively and subjectively compare the accuracy and reliability of 2-dimensional(2D) photography and 3-dimensional(3D) soft tissue imaging. Materials and Methods: Facial images of 50 volunteers(25 males, 25 females) were captured with a Nikon D800 2D camera (Nikon Corporation, Tokyo, Japan), 3D stereophotogrammetry (SPG), and laser scanning (LS). All subjects were imaged in a relaxed, closed-mouth position with a normal smile. The 2D images were then exported to Mirror® Software (Canfield Scientific, Inc, NJ, USA) and the 3D images into Proplan CMF® software (version 2.1, Materialise HQ, Leuven, Belgium) for further evaluation. For an objective evaluation, 2 observers identified soft tissue landmarks and performed linear measurements on subjects' faces (direct measurements) and both linear and angular measurements on all images(indirect measurements). For a qualitative analysis, 10 dental observers and an expert in facial imaging (subjective gold standard) completed a questionnaire regarding facial characteristics. The reliability of the quantitative data was evaluated using intraclass correlation coefficients, whereas the Fleiss kappa was calculated for qualitative data. Results: Linear and angular measurements carried out on 2D and 3D images showed excellent inter-observer and intra-observer reliability. The 2D photographs displayed the highest combined total error for linear measurements. SPG performed better than LS, with borderline significance (P=0.052). The qualitative assessment showed no significant differences among the 2D and 3D imaging modalities. Conclusion: SPG was found to a reliable and accurate tool for the morphological evaluation of soft tissue in comparison to 2D imaging and laser scanning.

A Study on Reliability and Training of Face-Bow Transfer Procedure (안궁의 신뢰성과 학습효과에 관한 연구)

  • So, Woong-Seup;Choi, Dae-Kyun;Kwon, Kung-Rock;Lee, Seok-Hyung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.4
    • /
    • pp.297-308
    • /
    • 2003
  • Face-bow is used to transfer models to the articulator in diagnosing the patient or treating problems associated with occlusion. However, there have been few reports on the reliability of the face-bow procedure and the relationship between the experience of the operator and the reliability of the face-bow procedure. The purposes of this study are to examine the reliability of the face-bow procedure and to evaluate whether the face-bow transferring has any training effect. Nine dentists working at M hospital conducted a face-bow transfer in one patient having a normal dentition and interdental relationship. The procedure was done two times a week for four weeks. The maxillary model was mounted to the articulator every time, then the landmarks on the maxillary right first molar, the maxillary left central incisor, and the maxillary left first molar were measured with a special three-dimensional instrument. These data were input into a computer, and evaluated statistically. The results were as follows ; 1. When examined with ANOVA test, the results were p=0.2040 in maxillary right first molar, p=0.0578 in maxillary left incisor, and p=0.1433 in maxillary left first molar. There was no significant(0< $p{\leq}0.05$). 2. Training 1) The correlation coefficient between trial and rejection was -0.578 when analyzed with T-distribution. The more we tried, the less errors we found. 2) When the S.D. of the first three trials was compared to the S.D. of the last three trials in face-bow transfer, the results showed that the former was larger than the latter in thirty-nine times, and the latter was larger than the former in fifteen times. The more we tried face-bow transfer, the less errors we found. 3. When the S.D. of x, y, z coordinates were examined, the S.D. of x coordinates had the largest measurement in five times, the S.D. of y coordinates had the largest measurement in four times, and the S.D. of z coordinates had the largest measurement in nine times. The possibility which the error can occur in z coordinate was the highest.

Comparison of Implant Torque Controllers using Detorque Value (풀림토크를 이용한 임플란트 토크조절기의 비교)

  • Huh, Yoon-Hyuk;Cho, Lee-Ra;Kim, Dae-Gon;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.419-432
    • /
    • 2010
  • Various torque generating devices have been developed and employed to apply a proper torque. These devices are usually calibrated by the manufacturer to apply appropriate torque levels for their specific implants and attachments. The purpose of this investigation was to determine and compare the accuracy of the torque controllers. In this study, 4 types of torque controllers were used; torque limiting device(TLD), torque indicating device(TID) and contra angle torque driver(CA), electronic torque controller(ETC). Digital torque gauge was employed to measure the de-torque value. Thirty cycles of tightening and loosening were repeated with each torque controller. All implant torque controllers have shown slight errors and deviations. The contra angle torque driver exhibited the most accurate data. In the limitation of this study, it would be recommended that the implant torque controllers should be checked whether uniformed and precise torque can be generated and a measuring error should be corrected.

Lateral Cephalometric Measurements of Class I Malocclusion Patients with Uncertainty (불확도를 고려한 Class I 부정교합 환자의 측방두부방사선영상 계측값)

  • Lee, Ji Min;Song, Ji-Soo;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Hojae;Cho, Hyo-Min;Shin, Teo Jeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.1
    • /
    • pp.65-74
    • /
    • 2018
  • The aim of this study was to obtain the traceability of the software used to analyze lateral cephalometry and to calculate the uncertainty of the measurements. Furthermore, this study aimed to provide a basis for obtaining standard references for measurement values for orthodontic treatment in children. Cephalometric data were collected from 100 children diagnosed with class I malocclusion between the ages 6 to 13 years who visited the pediatric dentist at Seoul National University Dental Hospital. To ensure traceability, a phantom device was created. Correction values were calculated by measuring the length and angle of the phantom device using the software. Type A uncertainty was calculated by obtaining the standard deviation of cephalometric measurements of 100 persons and the standard error of repeated measurements. Determination of the type B uncertainty was induced by minimum resolution and the position of the head. Using these, the combined standard uncertainty was obtained and the expanded uncertainty was calculated. The results of this study confirm that the currently used software has high accuracy and reliability. Furthermore, the uncertainty of orthodontic measurements in Korean children aged 6 to 13 years was calculated, and distribution range for class I malocclusion with 95% confidence interval was suggested.