A Study on Reliability and Training of Face-Bow Transfer Procedure

안궁의 신뢰성과 학습효과에 관한 연구

  • So, Woong-Seup (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University) ;
  • Choi, Dae-Kyun (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University) ;
  • Kwon, Kung-Rock (Department of Prosthodontics, Division of Dentistry, Graduate School, Kyung Hee University) ;
  • Lee, Seok-Hyung (Samsung Medical Center, College of Medicine, Sungkyunkwan University)
  • 소웅섭 (경희대학교 치과대학 치과보철학교실) ;
  • 최대균 (경희대학교 치과대학 치과보철학교실) ;
  • 권긍록 (경희대학교 치과대학 치과보철학교실) ;
  • 이석형 (성균관대학교 의과대학 치과학교실)
  • Published : 2003.12.30

Abstract

Face-bow is used to transfer models to the articulator in diagnosing the patient or treating problems associated with occlusion. However, there have been few reports on the reliability of the face-bow procedure and the relationship between the experience of the operator and the reliability of the face-bow procedure. The purposes of this study are to examine the reliability of the face-bow procedure and to evaluate whether the face-bow transferring has any training effect. Nine dentists working at M hospital conducted a face-bow transfer in one patient having a normal dentition and interdental relationship. The procedure was done two times a week for four weeks. The maxillary model was mounted to the articulator every time, then the landmarks on the maxillary right first molar, the maxillary left central incisor, and the maxillary left first molar were measured with a special three-dimensional instrument. These data were input into a computer, and evaluated statistically. The results were as follows ; 1. When examined with ANOVA test, the results were p=0.2040 in maxillary right first molar, p=0.0578 in maxillary left incisor, and p=0.1433 in maxillary left first molar. There was no significant(0< $p{\leq}0.05$). 2. Training 1) The correlation coefficient between trial and rejection was -0.578 when analyzed with T-distribution. The more we tried, the less errors we found. 2) When the S.D. of the first three trials was compared to the S.D. of the last three trials in face-bow transfer, the results showed that the former was larger than the latter in thirty-nine times, and the latter was larger than the former in fifteen times. The more we tried face-bow transfer, the less errors we found. 3. When the S.D. of x, y, z coordinates were examined, the S.D. of x coordinates had the largest measurement in five times, the S.D. of y coordinates had the largest measurement in four times, and the S.D. of z coordinates had the largest measurement in nine times. The possibility which the error can occur in z coordinate was the highest.

Keywords