• Title/Summary/Keyword: Dental composites

Search Result 173, Processing Time 0.019 seconds

Mechanical Properties of Polymeric Dental Restorative Composites Filled With Silica Treated by Heat at Various Temperatures (다양한 온도에서 열처리시킨 실리카가 충진된 치아수복용 고분자 복합체의 기계적 물성)

  • Kim, Ohyoung;Lee, Jung Soo;Seo, Kitaek;Kang, Doo Whan;Kang, Ho-Jong;Gong, Myoung-Seon;Oh, Myoung-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.16 no.4
    • /
    • pp.549-555
    • /
    • 2005
  • To evaluate the posterior and anterior restoration of polymeric dental restorative composite (PDRC), PDRC was prepared using a silica filler treated by heat at various temperatures. Compressive strength (CS) and diametral tensile strength (DTS) values were investigated to study the effect of a heat-treated silica on the mechanical properties of PDRC using the recommended dental specifications. Both the particle size and specific volume of silica were decreased upon increasing the heat treatment temperature. CS and DTS values of PDRC containing a heat-treated silica showed 1.2 and 1.3 times, respectively, higher than that of the PDRC containing a neat silica. Also, it was found that the lower heat treatment temperature, the better mechanical properties of PDRC were observed because there was less agglomeration between silica particles. Specially, PDRC using a silica treated at $600^{\circ}C$ showed superior mechanical strength.

Influence of the MgO-TiO2 Co-Additive Content on the Phase Formation, Microstructure and Fracture Toughness of MgO-TiO2-Reinforced Dental Porcelain Nanocomposites

  • Waiwong, Ranida;Ananta, Supon;Pisitanusorn, Attavit
    • Journal of the Korean Ceramic Society
    • /
    • v.54 no.2
    • /
    • pp.141-149
    • /
    • 2017
  • The influence of the co-additive concentration (0 - 45 wt% with an interval of 5 wt%) of MgO-$TiO_2$ on the phase formation, microstructure and fracture toughness of MgO-$TiO_2$-reinforced dental porcelain nanocomposites derived from a one-step sintering technique were examined using a combination of X-ray diffraction, scanning electron microscopy and Vickers indentation. It was found that MgO-$TiO_2$-reinforced dental porcelain nanocomposites exhibited significantly higher fracture toughness values than those observed in single-additive (MgO or $TiO_2$)-reinforced dental porcelain composites at any given sintering temperature. The amount of MgO-$TiO_2$ as a co-additive was found to be one of the key factors controlling the phase formation, microstructure and fracture toughness of these nanocomposites. It is likely that 30 wt% of MgO-$TiO_2$ as a co-additive is the optimal amount for $MgTi_2O_5$ and $Mg_2SiO_4$ crystalline phase formation to obtain the maximum relative density (96.80%) and fracture toughness ($2.60{\pm}0.07MPa{\cdot}m^{1/2}$) at a sintering temperature of $1000^{\circ}C$.

Effec of different zirconia primers on shear bond strengths of composite resin to bonded zirconia (지르코니아 프라이머 종류에 따른 복합레진-지르코니아의 전단결합강도)

  • Shi, Hong-Bing;Kim, Tae-Seok;Ahn, Jae-Seok;Lee, Jung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.135-142
    • /
    • 2016
  • Purpose: The aim of this research was to evaluate the influence of different surface treatments on the shear bond strength of zirconia ceramic to composite resin. Methods: Seventy two cylinder-shape (diameter: 5 mm; height: 12 mm) blocks of experimental industrially manufactured Y-TZP ceramic were abraded with $125{\mu}m\;Al_2O_3$ particles and randomly divided into 4 groups. All the materials were categorized as group Gc(control group - composite resin veneering on zirconia surface), Gr - composite resin veneering after surface treatment of Rocatec system (3M ESPE, Seefeld, Germany) group; Gz - composite resin veneering after surface treatment of Zirconia primer (Z-primer, Bisco, U.S.A) group; Gm - composite resin veneering after surface treatment of zirconia primer (Monobond plus, ivoclar vivadent AG, Liechtenstein) group. Two different zirconia primers and Rocatec system were used to zirconia cylinders (n=16) onto the zirconia surface. Zirconia specimens, polished and roughened, were pretreated and composite bilayer cylinders bonded using conventional adhesive techniques. Results: Shear bond strengths were analyzed using single-factor ANOVA(p<0.05). Bond strength values achieved after airbone particle abrasion and zirconia surface pre-treatments(p<0.05). Conclusion: Shear bond strength tests denmonstrated that zirconia primer is a viable method to improved bond strength between zirconia ceramic core and veneering composites.

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

Effects of the Variation of Silyl Hydride-to-Vinyl Ratios in Dental Polyvinylsiloxane Impression Materials (실리콘 폴리머의 비닐그룹에 대한 가교제의 Si-H 비율이 폴리비닐실록산 치과용 인상재의 물성에 미치는 영향)

  • Ju, Dong-Hyun;Jeong, Young-Hwa;Song, Ho-Jun;Choi, Chang-Nam;Park, Yeong-Joon
    • Elastomers and Composites
    • /
    • v.44 no.2
    • /
    • pp.150-155
    • /
    • 2009
  • This study examined the effects of the concentration variation of the silyl hydride (Si-H) functional group in polymethylhydrogen siloxane cross-linker and the vinyl-functional group in silicone prepolymer on the physical properties of the dental polyvinylsiloxane impression materials (PVS). When the SiH/Vinyl ratio was 1.6 (Group $\underline{C6}$ containing ${\underline{C}}ross$-linker $\underline{6}$ parts), the setting rate was too slow even though their tensile strength was the highest within the tested groups. When the SiH/Vinyl ratio was 3.2 (Group C12), the setting rate was too fast to allow appropriate working time even though their mechanical properties were good. The C14 group showed rather lower tensile strength compared to the groups having lower cross-linker contents. Notably, too much incorporation of cross-linker, like C16 group, induced delay of the setting, by which the mechanical and manipulation properties were detrimentally affected.

Effects of Silicone Polymer Blends on Physical Properties of Dental Polyvinylsiloxane Impression Materials (실리콘폴리머의 혼합사용이 폴리비닐실록산 치과용 인상재의 물성에 미치는 영향)

  • Lim, Chang-Ha;Kim, Min-Kang;Kim, Young-Chul;Park, Nam-Cook;Song, Ho-Jun;Park, Yeong-Joon
    • Elastomers and Composites
    • /
    • v.44 no.1
    • /
    • pp.76-83
    • /
    • 2009
  • The purpose of this study was to investigate the effects of combined use of several types of silicone polymers on the physical properties of the dental polyvinylsiloxane impression materials (PVS). Four types of silicone prepolymers having different molecular weight and vinyl group position, and two types of cross-linkers having differently located silyl hydride functional groups were used in various combinations for the formulation. The samples containing bimodal or trimodal prepolymers showed higher tensile strength, elongation at break, and elastic deformation than those containing only one type of prepolymer. The samples using CR210 cross-linker which has side- and terminal-silyl hydride groups showed higher elastic deformation and elongation at break than those using CR101 cross-liker which has side-only silyl hydride group. High vinyl content prepolymer having side vinyl group delayed setting even though it enhanced tensile strength. Further studies are needed to clarify the specific role of this component on setting time and to find appropriate controlling methods for making improved PVS with optimum workability.

Degree of Conversion and Polymerization Shrinkage of Low and High Viscosity Bulk-Fill Giomer-based and Resin-based composites (저점도 및 고점도 Bulk-fill Giomer 복합레진과 Bulk-fill 복합레진의 전환율과 중합수축)

  • Kim, Heera;Lee, Jaesik;Kim, Hyunjung;Kwon, Taeyub;Nam, Soonhyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • The aim of this study was to compare the degree of conversion and polymerization shrinkage of low and high viscosity bulk-fill giomer-based and resin-based composites. Two bulk-fill giomer (Beautifil Bulk Restorative (BBR), Beautifil Bulk Flowable (BBF)), two bulk-fill (Tetric N-Ceram Bulk-fill (TBF), SureFil SDR flow (SDR)) and two conventional resin composites (Tetric N-Ceram (TN), Tetric N-flow (TF)) were selected for this study. The degree of conversion was measured by using Fourier transform infrared spectroscopy. Polymerization shrinkage was measured with the linometer. For all depth, BBR had the lowest degree of conversion and SDR had the highest. At 4 mm, the degree of conversion of low and high viscosity bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). At the depth between 2 mm and 4 mm, there were significant difference with TBF, TN and TF (p < 0.05), while no significant difference in the degree of conversion was measured for BBR, BBF and SDR. Polymerization shrinkage of six resin composites decreased in the following order: TF > SDR > BBF > TBF > TN and BBR (p < 0.05). Polymerization shrinkage of bulk-fill giomer resin composites was lower than that of bulk-fill resin composites (p < 0.05). From this study, it is found that the bulk-fill giomer resin composites and TBF were not sufficiently cured in 4 mm depth. The degree of conversion of low and high viscosity bulk-fill giomer resin composites was significantly lower than bulk-fill resin composites in both 2 mm and 4 mm depths. Therefore, such features of bulk-fill giomer resin composites should be carefully considered in clinical application.

Fabrication and Characterization of the Ti-TCP Composite Biomaterials by Spark Plasma Sintering

  • Mondal, Dibakar;Park, Hyun-Kuk;Oh, Ik-Hyun;Lee, Byong-Taek
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.53.2-53.2
    • /
    • 2011
  • Ti metal has superior mechanical properties along with biocompatibility, but it still has the problem of bio-inertness thus forming weaker bond in bone/implant interface and long term clinical performance as orthopaedic and dental devices are restricted for stress shielding effect. On the other hand, despite the excellent biodegradable behavior as being an integral constituent of the natural bone, the mechanical properties of ${\beta}$-tricalcium phosphate $(Ca_3(PO_4)_2;\;{\beta}-TCP)$ ceramics are not reliable enough for post operative load bearing application in human hard tissue defect site. One reasonable approach would be to mediate the features of the two by making a composite. In this study, ${\beta}$-TCP/Ti ceramic-metal composites were fabricated by spark plasma sintering in inert atmosphere to inhibit the formation of $TiO_2$. Composites of 30 vol%, 50 vol% and 70 vol% ${\beta}$-TCP with Ti were fabricated. Detailed microstructural and phase characteristics were investigated by FE-SEM, EDS and XRD. Material properties like relative density, hardness, compressive strength, elastic modulus etc. were characterized. Cell viability and biocompatibility were investigated using the MTT assay and by examining cell proliferation behavior.

  • PDF

Modern Possibilities and Prospects of Nanotechnology in Dentistry

  • Sergiy, Chertov;Valery, Kaminskyy;Olha, Tatarina;Oleksii, Mandych;Andrii, Oliinyk
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.10
    • /
    • pp.97-106
    • /
    • 2022
  • Objective. Nanotechnology is spreading among all areas of life, from everyday devices to medicine. The concept of nanotechnology argues that not only can new physical and chemical properties of materials be discovered, but also the new potential of nanostructures when reduced to the nanoscale. The growing interest in the application of nanomaterials in dentistry contributes to the proliferation of the range of nanomaterials used by specialists. The purpose of this review of information sources was to analyze the prospects for the use of nanomaterials in dentistry. Methods. We used the bibliographic semantic method of research, for which we analyzed electronic databases of primary literature sources Scopus, Web of Science, Research Gate, PubMed, MDPI, and MedLine. English-language scientific articles published after 2017 were taken into consideration. Results. According to the results of a search study among modern information primary sources, nanotechnology improves the preventive properties of oral care products, improves the structural-mechanical and aesthetic properties of composite mixtures for dentistry, overcomes the problems of the clinical application of dental implants. Despite the prospects of nanotechnology applications in medicine in general and dentistry in particular, the existing economic and technological problems require a thorough solution for further implementation of nanostructures. Scientific novelty. For the first time, the analysis of modern trends in the application of nanotechnology in dentistry is carried out and the peculiarities of materials are highlighted, the problems and prospects of nanostructures implementation in modern dental implantology are given, physical, chemical, mechanical, and antibacterial properties of nanomaterials are evaluated. The effect of nanomaterials on the microbial adhesion of the tooth or implant surface is described. Practical significance. The presented publication can become a scientific basis for the solution of urgent problems hindering the introduction of nanotechnology into dental practice. Conclusions. Thus, the use of nanostructures opens up great opportunities for the treatment of a wide range of diseases, not only of dental nature but also in medicine in general.

COLOR STABILITY OF CURRENT PROSTHETIC COMPOSITES UNDER ACCELERATED AGING AND IMMERSION IN A COFFEE SOLUTION

  • Kim, Hyo-Jin;Heo, Seong-Joo;Koak, Jai-Young;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.225-235
    • /
    • 2002
  • The color stability of current prosthetic composites is unknown, even though the quality of composite materials has been improving. This study examined the intrinsic color stability of various current prosthetic resins (ceramic-polymers) after an accelerated aging process and the extrinsic color stability after immersion in a coffee solution. By comparing the amount of discoloration after aging with that without aging, the effect of the accelerated aging process on external discoloration could be evaluated. Three current prosthetic composites (Artglass, Targis, Sculpture), one light polymerized direct composite (Z100) and one dental porcelain control (Ceramco) were assessed. The color changes (${\Delta}$E) of all the specimens were determined using the CIE $L^{*}a^{*}b^{*}$ color order system with a reflected spectrophotometer. The results were as follows: 1. The prosthetic composite materials subjected to the accelerated aging test showed no significant difference in color changes (p >.05). 2. In the coffee solution immersion test after the aging process, the color changes of the Targis and Artglass groups were not different from that of the Z100 group, which showed the highest color change. 3. In the immersion only test, a significantly high color change was observed in the sculpture glazing group. 4. The aging process influenced on the color changes more in the Targis, Artglass and Z100 groups than in the Sculpture and Ceramco groups.