Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

임플란트 경부의 역사면 디자인이 변연골 응력분포에 미치는 영향 (The effect of implant system with reverse beveled platform design on marginal bone stress distribution)

  • 차지영;조진현;조광헌
    • 대한치과보철학회지
    • /
    • 제48권4호
    • /
    • pp.266-272
    • /
    • 2010
  • 연구 목적: 임플란트 경부 역사면의 디자인이 변연골 응력분포에 미치는 영향을 알아보기 위해 유한요소법을 사용하여 비교분석하였다. 연구 재료 및 방법:경부 직경 5.5 mm, 길이 8 mm의 매립형 (submerged type) 고정체 (Dentis Co., Daegu, Korea)를 연구모델로 선정하였다. 임플란트 경부 역사면의 디자인을 높이 (h, 0.4 mm, 1.0 mm)와폭경({5.5 - (3.34 + 2b)} / 2, [b, 0.2 mm, 0.3 mm, 0.4 mm])을 다르게 하여 총 여섯 가지의 실험 임플란트 조합으로 구분하였다. 축대칭 유한요소모델링을 이용하여 임플란트/악골 복합체에 대해 임플란트 장축에 평행한 방향으로 치관 교합면의 중심부에 수직 하중 100 N이 작용할 때 변연골의 최대압축응력을 산출하여 비교 하였다. 결과: 여섯 개의 모든 실험 임플란트 모델에서 변연골의 응력집중이 관찰되지 않았다. 변연골 응력은 임플란트 경부 역사면의 폭과 높이의 차이에 따라 달라지는 것이 관찰되었으며 사면각이 클수록 응력 집중이 증가하는 경향을 보였다. 결론: 임플란트 경부 역사면 디자인의 부여는 변연골 응력 분포 개선에 중요한 역할을 할 수 있을 것으로 여겨진다.

콘빔형 전산화단층영상을 이용한 치과임플란트 식립유도장치 개발 (Surgical stent for dental implant using cone beam CT images)

  • 최형수;김규태;최용석;황의환
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.171-178
    • /
    • 2010
  • Purpose : The purpose of this study is to develop a surgical stent for dental implant procedure that can be easily applied and affordable by using cone beam computerized tomography (CBCT). Materials and Methods : Aluminum, Teflon-PFA (perfluoroalkoxy), and acetal (polyoxymethylene plastic) were selected as materials for the surgical stent. Among these three materials, the appropriate material was chosen using the CBCT images. The surgical stent, which could be easily placed into an oral cavity, was designed with chosen material. CBCT images of the new surgical stent on mandible were obtained using Alphard-3030 dental CT system (Asahi Roentgen Co., Ltd., Kyoto, Japan). The point of insertion was prescribed on the surgical stent with the multiplanar reconstruction software of OnDemand3D (CyberMed Inc., Seoul, Korea). Guide holes were made at the point of insertion on the surgical stent using newly designed guide jig. CBCT scans was taken for the second time to verify the accuracy of the newly designed surgical stent. Results : Teflon-PFA showed radiologically excellent image characteristics for the surgical stent. High accuracy and reproducibility of implantation were confirmed with the surgical stent. Conclusion : The newly designed surgical stent can lead to the accurate implantation and achieve the clinically predictable result.

Stress Analysis of Dental Implant System Using Homogenization Technique

  • Lee, Jin-hee;Koh, Chul-Su;Choi, Kui-won
    • 대한치과의사협회지
    • /
    • 제32권11호통권306호
    • /
    • pp.805-814
    • /
    • 1994
  • 균질화기법을 적용하여 치과 임플란트 시스템에 대한 미세응력해석을 수행하였다. 균질화기법은 하악골내의 해면골과 같은 비균질 비등방성 구조체에 대한 물질모델을 설정하고 이를 이용하여 수치해석시 작은 계산량으로도 해면골조직의 미세단위까지의 응력해석을 가능케 하여준다. 균질화기법을 적용하여 계산된 해면골의 스트레스레벨은 기존의 방법으로 계산도니 수치보다 열배이상 높게 나타났는데, 이는 치과 임플란트 시스템의 응력상태에 대한 기존의 인식과 큰 차이를 보이고 있어 치과 임플란트 설계에 대한 전반적인 검토가 필요한 것으로 생각된다. 또한 균질화기법을 통하여 임플란트 시스템에 대한 측방력의 효과는 매우 크게 나타남을 확인할 수 있었고, 임플란트 시스템의 응력해석시 지나치게 단순화된 유한요소 모델을 사용함으로서 발생되는 오류가 지적되었다.

  • PDF

A Comparative Study on Corrosion Behavior of Ti-35Nb-5Ta-7Zr, Ti-6Al-4V and CP-Ti in 0.9 wt% NaCl

  • Saji, Viswanathan S.;Jeong, Yong Hoon;Choe, Han Cheol
    • Corrosion Science and Technology
    • /
    • 제8권4호
    • /
    • pp.139-142
    • /
    • 2009
  • Recently, quaternary titanium alloys of the system Ti-Nb-Ta-Zr received considerable research interest as potential implant materials because of their excellent mechanical properties and biocompatibility. However, only few reported works were available on the corrosion behavior of such alloys. Hence, in the present work, electrochemical corrosion of Ti-35Nb-5Ta-7Zr alloy, which has been fabricated by arc melting and heat treatment, was studied in 0.9 wt% NaCl at $37\pm1^{\circ}C$, along with biomedical grade Ti-6Al-4V and CP-Ti. The phase and microstructure of the alloys were investigated employing XRD and SEM. The results of electrochemical studies indicated that the corrosion resistance of the quaternary alloy was inferior to that of Ti-6Al-4V and CP Ti.

Epistaxis in dental and maxillofacial practice: a comprehensive review

  • Psillas, George;Dimas, Grigorios Georgios;Papaioannou, Despoina;Savopoulos, Christos;Constantinidis, Jiannis
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제48권1호
    • /
    • pp.13-20
    • /
    • 2022
  • The lifetime incidence of epistaxis in dental and maxillofacial practice has been reported to be as high as 60% and can be caused by dental implant placement, Le Fort I osteotomy, intranasal supernumerary tooth, odontogenic tumors, blood disorders and maxillofacial trauma. Most epistaxis cases are minor and easily managed with direct compression on the nares for 10 minutes. For more significant or recurrent epistaxis, other techniques might include electrocautery, anterior or posterior nasal packing, or Foley catheter balloon. For patients with refractory epistaxis, cauterization of the sphenopalatine artery under endonasal endoscopy or embolization of the internal maxillary artery should be performed. Epistaxis control is required in patients diagnosed with inherited or acquired bleeding disorders or with drug-induced coagulopathies during dental procedures. In these cases, hemostatic system adjustment and hemostasis achieved by local and adjunctive methods are required. Dentists and maxillofacial surgeons must be aware that the nasal cavity is a potential source of perioperative hemorrhage. Depending on the invasiveness of the dental intervention, preoperative involvement of the hematologist and cardiologist is usually necessary to reverse anticoagulation or to cease anticoagulant therapy.

지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 삼차원적 유한요소응력분석 (Three-Dimensional Finite Element Analysis for Comparison between Titanium Implant Abutment and Zirconia Implant Abutment)

  • 윤미정;김창섭;정창모;서승우
    • 구강회복응용과학지
    • /
    • 제27권1호
    • /
    • pp.51-61
    • /
    • 2011
  • 최근 심미 보철을 위해 높은 강도와 정밀도를 가지면서 동시에 자연치와 유사한 상아질 색을 구현할 수 있는 세라믹 계열의 지르코니아 임플란트 지대주가 보철 재료로서 각광을 받고 있다. 이에 본 연구에서는 삼차원적 유한요소응력분석을 이용하여 기존의 티타늄 소재의 임플란트 지대주와 지르코니아 소재의 임플란트 지대주의 응력분포비교를 통해 지르코니아 임플란트 지대주의 기계적 안정성을 간접적으로 확인하고자 하였다. 악골에 식립된 internal conical joint type과 external butt joint type의 임플란트 매식체에 티타늄 임플란트 지대주 또는 지르코니아 임플란트 지대주를 지대주 나사로 연결하고 상부에 금합금관을 장착하는 유한요소모형을 설계하였다. 교합면 중심으로부터 3mm 편측에 수직 방향으로 250N의 하중을 인가하여 교합력에 의해 임플란트 지대주에서 발생하는 등가응력분포를 분석하였다. 유한요소분석결과 지르코니아 임플란트 지대주와 티타늄 임플란트 지대주의 응력 분포는 유사하게 관찰되었으나 최대등가응력은 임플란트 연결 방식에 상관없이 티타늄 임플란트 지대주에 비해 지르코니아 임플란트 지대주가 약 15% 정도 높게 나타났다. 그럼에도 불구하고 티타늄에 비해 지르코니아의 더 높은 기계적 강도를 고려해 볼 때 임상에서도 기존의 티타늄 임플란트 지대주와 마찬가지로 지르코니아 임플란트 지대주도 임상적인 기계적 안정성을 가질 것으로 생각된다.

A case report about the reconstruction procedures of the previously failed cylinderical implants site using distraction osteogenesis

  • Lee, Jung-Tae;Park, Shin-Young;Yi, Yang-Jin;Kim, Young-Kyun;Lee, Hyo-Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제41권2호
    • /
    • pp.84-89
    • /
    • 2015
  • We report the eventually successful treatment of a huge bone defect and peri-implantitis following reconstruction of a previously failed intra-mobile cylinder implant system (IMZ) implant site using distraction osteogenesis (DO). In the anterior mandible, two IMZ implants failed and surgical debridement was performed in accordance to the patient's needs. Thereafter, mobility and suppuration were decreased and the patient visited the dental clinic on a regular basis for oral health maintenance. However, the inflammation did not resolve, and the bone destruction around the implants progressed for 4 years. Finally, the implants failed and a severe bone defect remained after implant removal. To reconstruct the bone defects, we attempted bone graft procedures. Titanium mesh was unsuccessfully used to obtain bone volume regeneration. However, DO subsequently was used to obtain sufficient bone volume for implant placement. The new implants were then installed, followed by prosthetic procedures. In conclusion, progression of peri-implantitis could not be arrested despite surgical intervention and repeated maintenance care for 3 years. Reconstruction of the peri-implantitis site was complicated due to its horizontal and vertical bone defects. Lesions caused by implant failure require an aggressive regenerative strategy, such as DO. DO was successful in reconstruction of a peri-implantitis site that was complicated due to horizontal and vertical bone defects.

Orthodontic treatment of gummy smile by maxillary total intrusion with a midpalatal absolute anchorage system

  • Hong, Ryoon-Ki;Lim, Seung-Min;Heo, Jung-Min;Baek, Seung-Hak
    • 대한치과교정학회지
    • /
    • 제43권3호
    • /
    • pp.147-158
    • /
    • 2013
  • This article describes the orthodontic treatment of a 31-year-old Korean female patient with gummy smile and crowding. The patient showed excessive gingival display in both the anterior and posterior areas and a large difference in gingival heights between the anterior and posterior teeth in the maxilla. To correct the gummy smile, we elected to intrude the entire maxillary dentition instead of focusing only on the maxillary anterior teeth. Alignment and leveling were performed, and a midpalatal absolute anchorage system as well as a modified lingual arch was designed to achieve posterosuperior movement of the entire upper dentition. The active treatment period was 18 months. The gummy smile and crowding were corrected, and the results were stable at 21 months post-treatment.

임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구 (A Study on the Retentive Force of Stud Attachments for Implant Overdenture)

  • 송은주;배은빈;최재원;배지현;김지영;이소현
    • 치위생과학회지
    • /
    • 제16권1호
    • /
    • pp.93-100
    • /
    • 2016
  • 이번 연구에서는 두 종류의 어태치먼트 시스템인 Kerator와 O-ring의 다양한 유지력을 가지는 matrix를 사용한 반복적인 착탈 후 평가를 통해 다음과 같은 결론을 얻었다. 초기 유지력은 KP군($62.09{\pm}6.00N$)에서 높았으며, 이어서 KR군($32.83{\pm}4.40N$), KB군($12.69{\pm}3.32N$), OO군($9.55{\pm}1.33N$), 그리고 OR군($9.35{\pm}0.71N$) 순으로 나타났다. 유지력 소실량은 KP군($22.26{\pm}8.02N$)에서 가장 높았으며, KR군($6.23{\pm}3.04N$), OO군($6.03{\pm}1.24N$), OR군($5.81{\pm}0.73N$), 그리고 KB군($0.87{\pm}1.46N$) 순으로 나타났다. 각 군 내의 초기 유지력과 2,500회의 착탈 후의 최종 유지력을 비교하였을 때, KB군을 제외한 모든 군에서 유의한 차이를 보였다(p<0.05). 어태치먼트 표면 마모양상은 Kerator와 O-ring의 matrix에서 눈에 띄는 변형과 손상이 관찰되었다. 각 patrix에서는 유지력 소실에 기여할 만한 변화는 관찰되지 않았다. 결론적으로 어태치먼트의 종류, 재료 그리고 초기 유지력 차이에 따라 마모양상이나 유지력 소실에 차이가 있음을 확 인하였고, 유지력이 보존되는 것처럼 보여도 SEM으로 관찰하였을 때 어태치먼트의 내부가 상당히 변형된 경우가 많았다. 따라서 적절한 유지력을 가진 어태치먼트를 선택하고 각 어태치먼트 시스템 별 적절한 교체시기를 숙지하여 그에따른 사용기간의 준수가 필요할 것으로 생각된다.