A Study on the Retentive Force of Stud Attachments for Implant Overdenture
![]() |
Song, Eun-Ju
(Goodwill Junior Dental Clinic, Goodwill Dental Hospital)
Bae, Eun-Bin (Department of Prosthodontics, School of Dentistry, Pusan National University) Choi, Jae-Won (Department of Prosthodontics, School of Dentistry, Pusan National University) Bae, Ji-Hyeon (Department of Prosthodontics, School of Dentistry, Pusan National University) Kim, Ji-Young (Department of Dental Hygiene, Kyungnam College of Information & Technology) Lee, So-Hyoun (Department of Prosthodontics, School of Dentistry, Pusan National University) |
1 | Yoon YS, Kwon YO: The present state and prospect of geriatric denture prosthetic dentistry affairs among community dental hygienists. J Dent Hyg Sci 6: 255-261, 2006. |
2 | Jung JO: A study on the actual conditions of denture prosthodontics used by the elderly aged 65 or older in Seoul. J Dent Hyg Sci 7: 113-119 2007. |
3 | Takeshita S, Kanazawa M, Minakuchi S: Stress analysis of mandibular two-implant overdenture with different attachment systems. Dent Mater J 30: 928-934, 2011. DOI |
4 | Ahn ES, Hwang JM, Shin MS: Dental utilization associated factors among elderly. J Dent Hyg Sci 15: 60-66, 2015. DOI |
5 | Van Waas MA: The influence of clinical variables on patients' satisfaction with complete dentures. J Prosthet Dent 63: 307-310, 1990. DOI |
6 | Oh SC, Han JS, Kim MJ: Implant supported overdenture using milled titanium bar with Locator attachment on fully edentulous maxillae: a case report. J Dent Rehabil Appl Sci 27: 223-231, 2011. |
7 | Miller PA: Complete dentures supported by natural teeth. J Prosthet Dent 8: 924-928, 1958. DOI |
8 | Yeo DH, Lim JH, Cho IH: A study on the changes in retention of clips used to retain implant-supported overdenture. J Korean Acad Prosthodont 36: 566-580, 1998. |
9 | Seo MJ, Lee JS, Cho IH: A comparative study on the retention of implant overdenture according to the shape and the number of magnetic attachment. J Korean Acad Stomatognathic Funct Occlusion 24: 169-181, 2008. |
10 | Misch CE: Contemporary implant dentistry. 2nd ed. CV Mosby, Missouri, pp.67-72, 1999. |
11 | Davis DM. The role of implants in the treatment for the edentulous patients. Int J Prosthodont 3: 42-50, 1990. |
12 | Raghoebar GM, Meijer HJ, van't HM, Stegenga B, Vissink A: A randomized prospective clinical trial on the effectiveness of three treatment modalities for patients with lower denture problems. A 10 year follow-up study on patient satisfaction. Int J Oral Maxillofac Surg 32: 498-503, 2003. |
13 | Walton JN, Ruse ND: In vitro changes in clips and bars used to retain implant overdentures. J Prosthet Dent 74: 482-486, 1995. DOI |
14 | Cha MS, Kim DG, Park CJ, Cho LR: A literature review on locator attachment for implant overdenture. J Dent Rehabil Appl Sci 29: 127-140, 2012. |
15 | Cardoso RC, Gerngross PJ, Dominici JT: Survey of currently selected dental implants and restorations by prosthodontists. Int J Oral Maxillofac Implants 28: 1017-1025, 2013. DOI |
16 | Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY: Clinical complications with implants and implant prostheses. J Prosthet Dent 90: 121-132, 2003. DOI |
17 | Botega DM, Mesauita MF, Henriques GEP, Vaz LG: Retention force and fatigue strength of overdenture attachment systems. J Oral Rehabil 31: 884-889, 2004. DOI |
18 | Besimo CH, Graber G, Fluhler M: Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro. J Oral Rehabil 23: 372-378, 1996. DOI |
19 | Wichmann MG, Kuntze W: Wear behavior of precision attachments. Int J Prosthodont 12: 409-414, 1999. |
20 | Bayer S, Steinheuser D, Gruner M, et al.: Comparative study of four retentive anchor systems for implant supported overdentures - retention force changes. Gerodontology 26: 268-272, 2009. DOI |
21 | Alsabeeha NH, Payne AG, Swain MV: Attachment systems for mandibular two-implant overdentures: a review of in vitro investigations on retention and wear features. Int J Prosthodont 22: 429-440, 2009. |
22 | Sinclair PM, Little RM: Maturation of untreated normal occlusions. Am J Orthod 83: 114-123, 1983. DOI |
23 | Michelinakis GBC, Smith PW: The influence of interimplant distance and attachment type on retention characteristics of mandibular overdenture on 2 implants: initial retention values. Int J Prosthodont 19: 507-512, 2006. |
24 | Stephens GJ, Vitale N, O'Sullivan E, McDonald A: The influence of interimplant divergence on the retention characteristics of locator attachments, a laboratory study. J Prosthodont 23: 467-475, 2014. DOI |
25 | Son CY, Jeong CM, Jeon YC, Lim JS, Jeong HC: Comparative studies of retentive forces in maxillary overdenture bar attachments. J Korean Acad Prosthodont 43: 650-661, 2005. |
26 | Feine JS, Carlsson GE, Awad MA, et al.: The McGill consensus statement on overdentures. Mandibular two- implant overdentures as first choice standard of care for edentulous patient. Int J Oral Maxillofac Implants 17: 601-602, 2002. |
27 | Pigozzo MN, Mesquita MF, Henriques GE, Vaz LG: The service life of implant-retained overdenture attachment systems. J Prosthet Dent 102: 74-80, 2009. DOI |
28 | Schallamach A. A theory of dynamic rubber friction. Wear 6: 375-382, 1963. DOI |
29 | Winkler S, Piermatti J, Rothman A, Siamos G: An overview of the O-ring implant overdenture attachment: Clinical reports. J Oral Implantol 28: 82-86, 2002. DOI |
![]() |