• 제목/요약/키워드: Delta power

검색결과 753건 처리시간 0.025초

대용량 터빈발전기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in Large Turbine Generator Stator Windings)

  • 김희동;이영준;박덕현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2093-2096
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in three large turbine generators. Nondestructive tests have been carried out on stand-still generators which have been in service for 2 to 30 years. In most cases these tests include ac current increase rate($\Delta$I), delta tan delta( ${\Delta}tan{\delta}$), and maximum partial discharge(Qm). Gen. 2 show that the $tan{\delta}$ is higher than other two generators in the $tan{\delta}$-voltage curve. Partial discharge(PD) patterns were observed internal, corona and treeing discharges in large turbine generators. The PD tests were confirmed the correlation between discharge patterns and the kinds of defects.

  • PDF

Improved Switching Frequency in Delta Modulated Inverter for UPS Applications

  • Sodaban, C.;Tipsuwanporn, V.;Thepsatorn, P.;Piyarat, W.;Witheephanich, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.986-989
    • /
    • 2004
  • The concept and results of a simple constant switching frequency delta modulation scheme suitable for DC-AC power conversion in uninterruptable power supply (UPS) applications are presented. Unlike the traditional delta modulation scheme, the scheme has a well defined harmonic spectrum, resulting in a simple filter design and reduced radio interference.

  • PDF

델터 변조 방식을 이용한 전류형 무효전력 보상장치 (Current-Fed Reactive Power Compensator Using Delta Modulation Technique)

  • 백형래;김한성
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.244-252
    • /
    • 1992
  • This paper describes a reactive power compensator using current-source delta modulation converter, which compensates the reactive power in the ac sides of 3-phase rectifier. In the conventional current control methods for the current-type reactive power compensators, it is usual to compare the reactive reference current signal with the triangular wave and hence to generate the ON-OFF signals for the reactive power compensator. To improve the response as well as the control capability, the delta modulated current control technique is used in this paper. As a result, the input power factor is improved close to unity and both simulation and experimental results show good compensating performances.

  • PDF

Relations between Gaussian width of Power Excess and Other Global Seismic Properties of Solar-like Stars from Main-sequence to Subgiant

  • Kim, Ki-Beom;Chang, Heon-Young
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.58.3-58.3
    • /
    • 2016
  • The Kepler space mission provides quantitative and qualitative photometric time series of oscillating stars. It is possible to examine statistical study with seismic properties of solar-like stars. Global seismic properties - large frequency separation (${\Delta}{\nu}$), frequency of maximum power (${\nu}_{max}$) and amplitude of Gaussian envelope (A) widely have been used to determine empirical scaling relations for inferring the stellar physical quantities - mass, age and temperature. We aim to confirm whether width of Gaussian envelope on power excess (${\delta}{\nu}_{env}$) can be used with parameter of scaling relation before redgiant phase using Kepler data. Therefore we analyze the characteristics of ${\delta}{\nu}_{env}$ of 129 solar-like stars from main-sequence to subgiant. We have demonstrated that ${\delta}{\nu}_{env}$ has highly correlations with global parameters - ${\Delta}{\nu}$ and ${\nu}max$. We have also found the break of ${\delta}{\nu}_{env}-{\Delta}{\nu}$ and ${\nu}_{max}$ relations.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

고압전동기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in High Voltage Motor Stator Windings)

  • 김희동;박의갑;박완조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2392-2395
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in six high voltage motors. Nondestructive tests have been carried out on stand-still motors. These tests include ac current increase rate($\Delta$I), delta tan delta(${\Delta}tan{\delta}$), and maximum partial discharge(PD). AC current and $tan{\delta}$ were measured by Schering bridge. The measurement of PD patterns were conducted using digital partial discharge detector. PD patterns were observed treeing and internal discharges in Motor 1 and 2. The stator windings of two motors were found to be in a poor condition and their were recommended to rewind. The stator. windings of four motors were judged to be in serviceable condition.

  • PDF

수동형 적분기(Passive Integrator)를 이용한 저전력 이산시간 Incremental Delta Sigma ADC (Low Power Discrete-Time Incremental Delta Sigma ADC with Passive Integrator)

  • 오군석;김진태
    • 전자공학회논문지
    • /
    • 제54권1호
    • /
    • pp.26-32
    • /
    • 2017
  • 본 논문에서는 설계 요구가 높고, 전력 소모가 높은 opamp를 이용하는 기존의 능동형 적분기를, 수동형 적분기로 대체하여 고속의 저전력, 고해상도 특성을 갖는 incremental delta-sigma ADC를 소개한다. 능동형 적분기에서 수동형 적분기로의 변환을 위해, 기존의 능동형 적분기의 특성을 분석하였다. 이를 바탕으로 opamp의 설계 요구를 낮추고, 더 나아가 opamp를 사용하지 않는 저전력의 수동형 적분기를 제안하였다. 65nm 공정을 이용하여 수동형 적분기로 구성된 1차 single-bit incremental delta-sigma ADC를 설계하였다. Transistor-level 시뮬레이션 결과, 이는 supply 전압이 1.2V인 상황에서 modulator만 0.6uW, digital filter를 포함한 ADC 전체에서 6.25uW를 소모하며 BW 22KHz, SNDR 71dB, dynamic range 74.6dB을 달성하였다.

A Low-power High-resolution Band-pass Sigma-delta ADC for Accelerometer Applications

  • Cao, Tianlin;Han, Yan;Zhang, Shifeng;Cheung, Ray C.C.;Chen, Yaya
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권3호
    • /
    • pp.438-445
    • /
    • 2017
  • This paper presents a low-power high-resolution band-pass ${\Sigma}{\Delta}$ ADC for accelerometer applications. The proposed band-pass ${\Sigma}{\Delta}$ ADC consists of a high-performance 6-th order feed-forward ${\Sigma}{\Delta}$ modulator with 1-bit quantization and a low-power, area-efficient digital filter. The ADC is fabricated in 180 nm 1P6M mixed-signal CMOS process with a die area of $5mm^2$. This high-resolution ADC got 90 dB peak signal to noise plus distortion ratio (SNDR) and 96 dB dynamic range (DR) over 4 kHz bandwidth, while the intermediate frequency (IF) is shifting from 100 KHz to 200 KHz. The power dissipation of the chip is 5.6 mW under 1.8 V (digital)/3.3 V (analog) power supply.

Binary Power Amplifier with 2-Bit Sigma-Delta Modulation Method for EER Transmitter

  • Lim, Ji-Youn;Cheon, Sang-Hoon;Kim, Kyeong-Hak;Hong, Song-Cheol;Kim, Dong-Wook
    • ETRI Journal
    • /
    • 제30권3호
    • /
    • pp.377-382
    • /
    • 2008
  • A novel power amplifier for a polar transmitter is proposed to achieve better spectral performance for a wideband envelope signal. In the proposed scheme, 2-bit sigma-delta (${\Sigma}{\Delta}$) modulation of the envelope signal is introduced, and the power amplifier configuration is modified in a binary form to accommodate the 2-bit digitized envelope signals. The 2-bit ${\Sigma}{\Delta}$ modulator lowers the noise of the envelope signal by fine quantization and thus enhances the spectral property of the RF signal. The Ptolemy simulation results of the proposed structure show that the spectral noise is reduced by 10 dB in a full transmit band of the EDGE system. The dynamic range is also enhanced. Since the performance is improved without increasing the over-sampling ratio, this technique is best suited for wireless communication with high data rates.

  • PDF