Browse > Article
http://dx.doi.org/10.5370/JEET.2011.6.2.384

Analysis of Insulation Quality in Large Generator Stator Windings  

Kim, Hee-Dong (Member of the KIEE, Korea Electric Power Corporation (KEPCO) Research Institute)
Kong, Tae-Sik (Member of the KIEE, Korea Electric Power Corporation (KEPCO) Research Institute)
Ju, Young-Ho (Member of the KIEE, Korea Electric Power Corporation (KEPCO) Research Institute)
Kim, Byong-Han (Member of the KIEE, Korea Electric Power Corporation (KEPCO) Research Institute)
Publication Information
Journal of Electrical Engineering and Technology / v.6, no.3, 2011 , pp. 384-390 More about this Journal
Abstract
To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.
Keywords
Deterioration; Generator; Diagnostic test; Accelerated aging; Stator bar; Partial discharge; Dissipation factor;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 1
연도 인용수 순위
1 Hee-Dong Kim, Young-Jun Lee and Young-Ho Ju, “Characteristics of Insulation Aging in Large Generator Stator Windings”, Trans. KIEE, Vol. 58, No. 7, pp. 1375-1379, 2009.   과학기술학회마을
2 Hee-Dong Kim, “Analysis of Insulation Aging Mechanism in Generator Stator Windings”, Journal of the KIEEME, Vol. 15, No. 2, pp. 119-126, 2002.
3 Hee-Dong Kim, “Assessment of Insulation Condition in Operating Large Turbine Generator”, Trans. KIEE, Vol. 53C, No. 6, pp. 324-329, 2004.
4 R. Morin, R. Bartnikas and P. Menard, “A Three-Phase Multi-Stress Accelerated Electrical Aging Test Facility for Stator Bars”, IEEE Trans. on Electrical Conversion, Vol. 15, No. 2, pp. 149-156, 2000.   DOI   ScienceOn
5 Y. J. Kim and J. K. Nelson, “Assessment of Deterioration in Epoxy/Mica Machine Insulation”, IEEE Trans. on Electrical Insulation, Vol. 27, No. 5, pp. 1026-1039, 1992.   DOI   ScienceOn
6 K. Kimura and Y. Kaneda, “The Role of Microscopic Defects in Multistress Aging of Micaceous Insulation”, IEEE Trans. on Dielectrics and Electrical Insulation, Vol. 2, No. 3, pp. 426-432, 1995.   DOI   ScienceOn
7 Y. Ikeda and H. Fukagawa, “A Method for Diagnosing the Insulation Deterioration in Mica-Resin Insulated Stator Windings of Generator”, Yokosuka Research Laboratory Rep. No. W88046, 1988.
8 H. Zhu, C. Morton and S. Cherukupalli, “Quality Evaluation of Stator Coils and Bars under Thermal Cycling Stress”, Conference Record of the 2006 IEEE International Symposium on Electrical Insulation, pp. 384-387, 2006.   DOI
9 C. Hudon and M. Belec, “Partial Discharge Signal Interpretation for Generator Diagnostics”, IEEE Trans. on Dielectrics and Electrical Insulation, Vol. 12, No. 2, pp. 297-319, 2005.   DOI   ScienceOn