• Title/Summary/Keyword: DC bus

Search Result 271, Processing Time 0.027 seconds

Improved Conditional Integrator Anti-Windup Method for Seamless Transfer of Bidirectional DC-DC Converter in Grid-Connected Battery Energy Storage System (계통연계형 배터리 에너지저장장치용 양방향 DC-DC 컨버터의 무순단 절체를 위한 조건부 적분 안티-와인드업 연구)

  • Eom, Jun-Yong;Choi, Sung-Jin;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.333-342
    • /
    • 2020
  • Power exchanges between the grid and the battery through a bidirectional DC-DC converter are essential for DC microgrid systems. In general, the battery is charged when the grid is connected, and the system is powered by the battery when the grid is disconnected. In this mode transition, the saturation of the voltage controller slows down output response and produces large transient errors in DC link voltage. To solve this problem, a novel anti-windup design is proposed to improve anti-windup performance further. The proposed method stabilizes DC bus voltage through a wider range of battery voltage with faster transition compared with that of conventional methods. The proposed method is verified through an experimental setup composed of a 125 W laboratory-scale DC microgrid system.

Implementation of Inverter Systems for DC Power Regeneration

  • Kim Kyung-Won;Yoon In-Sic;Seo Young-Min;Hong Soon-Chan;Yoon Duck-Yong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.126-131
    • /
    • 2001
  • This paper deals with implementation of inverter systems for DC power regeneration, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, a three-phase square-wave inverter system is adopted. To control the regenerated power, the magnitude and phase of fundamental output voltages should be appropriately controlled in spite of the variation of input DC voltage. Inverters are operated with modified a-conduction mode to fix the potential of each arm. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified $\alpha-conduction\;mode\;with\;\delta\;and\;\alpha$, a DPLL for frequency followup, and power circuit.

  • PDF

The Automatic Precision Measurement of RF Voltage using Power and Impedance Standards (전력과 임피던스표준을 이용한 RF전압의 정밀 자동측정)

  • Shin, Jin-Kook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.3A
    • /
    • pp.319-323
    • /
    • 2007
  • In this paper, the automatic precision measurement of RF voltage has been done using the power and impedance standards [1] in the frequency range of 50 to 1000 MHz. A coaxial microcalorimeter and an automatic network analyzer were used for the determination of the RF-DC differences and the total uncertainty is about 1.0 %. A HP computer, a commodore computer and IEEE-488 interface bus were used for measuring the effective efficiency of thermistor mount and the RF-DC difference of thermal voltage converter, All processes of measurement were accomplished by self-developed program automatically.

Design and Operation of DC Home Grid with PV-Battery-Ultracapacitor (태양광-배터리-수퍼캡을 갖는 직류 홈 그리드의 설계 및 운영)

  • Heryanto, Nur A.;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.103-110
    • /
    • 2020
  • In this study, the design and operating strategy of DC home grid with PV, battery, and ultracapacitor have been discussed, The proposed sizing method can find the optimum size of the battery and PV which can reduce yearly utility energy consumption, whereas the control scheme can maintain the DC-bus voltage level of the DC home grid under different operating conditions, where day or night time operation, load and PV power levels, and the maximum current and state-of-charge of batter are considered. In addition, a supervisory power management strategy has been suggested, and its validity has been verified by HILS (hardware in-the-loop simulation) results.

Design and Control of DC/AC Converters in Parallel with Diode Rectifiers for Regenerative Applications

  • Gao, Zhigang;Li, Rui;Lu, Qi
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.1071-1087
    • /
    • 2017
  • This paper introduces a DC/AC converter, which can be connected in parallel with a diode rectifier for regenerative applications. The DC/AC converter is supposed to transmit regenerative energy to the power grid when a motor is braking. Isolation transformers are not needed in the topology, which can reduce the size and cost. An analysis of the zero-order current existing in the system is carried out. In addition, algorithms to minimize the zero-order current, control the power factor and keep the DC bus voltage stable are discussed. A 55kW industrial prototype is built to verify the proposed analysis and control strategies.

Development of Hardware In-the-Loop Simulation System for Testing Power Management of DC Microgrids Based on Decentralized Control (분산제어 기반 직류 마이크로그리드 전력관리시스템의 HIL 시뮬레이션 적용 연구)

  • To, Dinh-Du;Le, Duc-Dung;Lee, Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.3
    • /
    • pp.191-200
    • /
    • 2019
  • This study proposes a hardware-in-the-loop simulation (HILS) system based on National Instruments' PXI platform to test power management and operation strategies for DC microgrids (MGs). The HILS system is developed based on the controller HIL prototype, which involves testing the controller board in hardware with a real-time simulation model of the plant in a real-time digital simulator. The system provides an economical and effective testing function for research on MG systems. The decentralized power management strategy based on the DC bus signaling method for DC MGs has been developed and implemented on the HILS platform. HILS results are determined to be similar to those of the off-line simulation in PSIM software.

Determining Level-of-Service Criteria of Headway Adherence (버스 운행 정시성의 서비스수준 기준산정)

  • Go, Seung-Yeong;Park, Jun-Sik
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.2
    • /
    • pp.151-160
    • /
    • 2005
  • In case of public transit such as bus system, the probability concept is used to evaluate the Level-of-Service of the operations. And each levels could be classified according to the linear probability value. (TCQSM: Transit Capacity and Quality of Service Manual-2nd Edition, TRB, Washington DC., 2003) In this case, the drivers or passengers wouldn't think that the service level isn't equivalent to the linear probability value. Thus the linear probability value doesn't exactly reflect the service level. This study shows the problems of using the linear probability value in classifying the service level through the case of evaluation of bus operation's punctuality, presented in TCQSM. To make up for the problems of such case, two methodologies are presented in this study. The method of determining Level-of-Service criteria using probability density of headway variation's distribution, presented in this paper, adequately reflects passenger's expected waiting time. According to the application result to real bus operation data, it tis better than the method of TCQSM to evaluate the reliability of bus operations. However further research about the relations between utility difference and passenger feeling of service level in necessary to apply the method that uses the utility function. It remains as the limitation of this paper.

H-type Structural Boost Three-Level DC-DC Converter with Wide Voltage-Gain Range for Fuel Cell Applications

  • Bi, Huakun;Wang, Ping;Che, Yanbo
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1303-1314
    • /
    • 2018
  • To match the dynamic lower voltage of a fuel cell stack and the required constant higher voltage (400V) of a DC bus, an H-type structural Boost three-level DC-DC converter with a wide voltage-gain range (HS-BTL) is presented in this paper. When compared with the traditional flying-capacitor Boost three-level DC-DC converter, the proposed converter can obtain a higher voltage-gain and does not require a complicate control for the flying-capacitor voltage balance. Moreover, the proposed converter, which can draw a continuous and low-rippled current from an input source, has the advantages of a wide voltage-gain range and low voltage stress for power semiconductors. The operating principle, parameters design and a comparison with other converters are presented and analyzed. Experimental results are also given to verify the aforementioned characteristics and theoretical analysis. The proposed converter is suitable for application of fuel cell systems.

Design and Fabrication of Light-Weight Composit Bus Bar (복합경량 부스바의 설계 및 제작)

  • Bae Joon-Han;Bea Duck-Kweon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.8
    • /
    • pp.334-340
    • /
    • 2006
  • Copper is widely used in electric wire, cable, conductor in electric devices. As the demand for electric power is increasing rapidly, electric power devices are getting amazingly bigger and complicated. The using of light-weight conductor can reduce the size and making cost of the electric devices. In high-frequency application, Electric current in a conductor tends to shift to the surface of the conductor, resulting in an uneven current distribution in the inner conductor. In the extreme case the current may essentially concentrate in the 'skin' of the inner conductor as a surface current. In high frequency application, therefore, inner area of copper conductor may replace with aluminum conductor, which reduces the weight of conductor. This paper describes the manufacture and evaluation of composite conductors made of copper and aluminum. The optimum extruding ratio was 16 at $300^{\circ}C$. The electrical resistance of manufactured composite bus bar was $57{\mu}{\Omega}$ at DC and $49.5{\mu}\{Omega}$ at 300Hz.

Formal Verification of I-Link Bus for CCA Board (CCA 보드를 위한 I-Link 버스의 정형 검증)

  • 남원홍;성창훈;최진영;기안도;한우종
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.04a
    • /
    • pp.45-47
    • /
    • 2000
  • 본 연구는 심볼릭 모델 체커 중의 하나인 SMV(Symbolic Model Verifier)를 이용하여 한국전자통신연구원(ETRI)에서 개발한 CCA(Cache Coherent Agent) 보드를 위한 I-Link Bus(Inside Bus)의 몇 가지 특성(property)들을 검증하여 I-Link Bus의 요구사항(requirement)이 만족됨을 보인다. 이 검증에서는 I-Link Bus의 모델을 SMV 입력 언어로 명세하며, 검증할 특성들을 시제 논리(temporal logic)를 이용하여 나타낸다. 검증을 통해서 I-Link Bus와 PIF(Processor Interface), DC(Directory Controller), RC(Remote access cache Controller)모듈들이 중재기 우선 순위, send 우선 순위, 중재 요청 신호의 관리, liveness등의 특성들을 만족한다라는 것을 검증하였다.

  • PDF