• Title/Summary/Keyword: Cut-off wall

Search Result 60, Processing Time 0.023 seconds

Numerical Investigation on Seepage Stability in Offshore Bucket Cut-off Walls (수치해석을 이용한 대형원형강재 가물막이의 침투 안정성 분석)

  • Ssenyondo, Vicent;Tran, Van An;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.73-82
    • /
    • 2017
  • Recently, offshore bucket cut-off walls were developed to solve several problems in conventional offshore cut-off walls. In this study, a numerical analysis was carried out to investigate the seepage stability of offshore bucket cut-off walls. The ground was assumed as uniform homogeneous sand and steady state flow conditions were applied. The flow condition was compared among 2-dimensional flow (2-D), 2-dimensional concentrated flow (2-DC), and axisymmetric flow. The analysis results showed that the seepage velocities in axisymmetric flow were about 1.5 and 2 times larger than those of 2-DC and 2-D flow conditions, respectively. Thereafter, the axisymmetric flow condition was applied because the seepage flow was concentrated toward the center of the circular-shaped wall. A parametric study was performed varying bucket radius, penetration depth, total head difference between in and outside of the wall. The exit gradient, which used for the calculation of piping stability, decreased with increase of the penetration depth and bucket radius. Design charts were proposed to estimate the factor of safety and the exit gradient at various analysis conditions. Finally, the design equation was proposed to calculate the exit gradient for the preliminary design of the bucket cut-off wall.

Aperture Cut-off Filter for Reduction of Electromagnetic Field Penetration through a Slot in Conducting Screens (도체평판의 슬롯 침투 전자파 저감을 위한 개구면 차단필터)

  • Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1201-1211
    • /
    • 2014
  • The purpose of this paper is to present the aperture cut-off filter for reduction of electromagnetic field penetration through a slot in conducting screen. The reduction characteristics of electric field penetration by the aperture cut-off filter are considered. In order to establish the concept of the aperture cut-off filter, the integral equation on the slot aperture field distribution is derived and solved by method of moments, and the reduction characteristics of penetration electric fields for the incident plane wave are calculated. The numerical results showed that the aperture cut-off filter for reduction of electric field penetration through the slot can be realized. To check the validity of the concept of an aperture cut-off filter and the theoretical analysis, the calculated electric field penetration of the metallic wall with narrow slot were compared with the experimental results.

The Compatibility of Slurry Wall Materials with Leachate for Cut -off of Contaminated Sites (오염지역 차폐용 슬러리월 재료와 침출수의 반응 특성)

  • 이용수;정하익
    • Geotechnical Engineering
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 1997
  • Cut-off methods of controlling leachate migration from waste landfills and contaminated sites are studied. Permeability and chemical compatibility tests are prrforlned on slurry wall materials including soil-bentonite, cement-bentonite, cement / fly ash-bentonite, plastic concrete. Hydraulic conductivity of soil-bentonite mixture is the lowest of these four bacuill materials. The leachate from municipal solid waste has little influence on the permeability of the backfill materials. The bentonite slurry becomes flocculated and aggregated when exposed to the leachate. The results of the permeability test showed that the hydraulic conductivities of the backfill materials are in the order soil-beiltonite, Plastic concrete, cement-bentonite. And the result c: the compatibility test showed increase in permeability due to the effects of leachate. Thus, in designing the slurry wall it is essential to check the behaviour of the bentonite slurry and backfill materials on the compatibility with the contaminants.

  • PDF

Development and Field Test of a Smart-home Gas Safety Management System (스마트 홈 가스안전관리 시스템 개발 및 현장시험)

  • Park, Gyou-Tae;Kim, Eun-Jung;Kim, In-Chan;Kim, Hie-Sik
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.128-135
    • /
    • 2012
  • In this paper, we proposed a system and a scenario to raise efficiency of gas safety management by developing wireless ZigBee communication modules, smart-home gas safety appliances and the system suitable for gas safety. Our designed system consists of a micom gas meter, an automatic extinguisher, sensors, and a wall-pad. A micom-gas-meter monitors gas flow, gas pressure, and earthquake. An automatic fire extinguisher checks combustible gas leaks and temperature of $100^{\circ}C$(cut off) and $130^{\circ}C$(fire). Sensors measure smoke and CO gas. In our novel system, a micom-gas meter cut off inner valve with warnings, an automatic fire extinguisher cut off middle valve and spray extinguishing materials, and sensors generate signals when detecting smoke and CO and then take a next action. Gas safety appliances and sensors automatically takes measures, and transmit those information to a wall-pad. The wall-pad again transmits real time information to server. Users can check and manage gas safety situations by connecting BcN server through web or mobile application. We hereby devised scenarios for gas safety and risk management based on the smart, and demonstrated their efficiency through test applied to filed.

Evaluation and Improvement for Seismic Resistant Capacity of Reinforced Concrete Infilled Masonry Frame (철근콘크리트 프레임면내 조적벽체의 내진성능 평가 및 개선)

  • 신종학;하기주;최민권;전하석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.411-414
    • /
    • 1999
  • Five reinforced concrete rigid frame and masonry infilled wall and cut off type masonry infilled wall were constructed and tesed during vertical and cycle loads simultaneously. Experimental programs were accomplished to evaluate the structural performance of test spcimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. Test variables are hoop reinforcement ratio and masonry infilled wall with on without. All the specimens were modelling in one-third scale size.

  • PDF

Evaluation on Field Applicability of Cast-In-Place Pile using Surfactant Grout (계면활성제계 그라우트를 활용한 흙막이 벽체공법(CIP)의 현장 적용성 평가)

  • Do, Jinung;Kim, Hakseung;Park, Bonggeun;Lee, Juhyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.75-83
    • /
    • 2016
  • In case of underground construction affected by groundwater, CIP (Cast-In-Place Pile) method is generally used to resolve the geo-hydraulic problem. However, as this method has poor connectivity between piles, an auxiliary method for cut-off is needed in many cases. In this study, a new concept earth retaining wall method (H-CIP) with no auxiliary method, by using surfactant grout (Hi-FA) which improves antiwashout and infiltration ability, is introduced, and its field applicability is evaluated. CIP and H-CIP piles were installed with same ground conditions, and field and laboratory tests were conducted to verify the performance. As results, newly contrived H-CIP method shows higher field performance for cut-off and strength than conventional CIP method.

Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification (특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석)

  • 박성호;김상수;오명도
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.285-291
    • /
    • 1991
  • A two-stage slit type virtual impactor based on the concept of the single stage virtual impactor has been designed, fabricated, and evaluated for the purpose of concentrating the suspended particles in the air with the size range of 1.8-4.5 .mu.m and handling large flow volume. Monodisperse methylene blue particles have been generated with vibrating orifice aerosol generator (VOAG). The separation efficiency and concentration efficiency have been measured by the UV-visible absorption spectrometry. Previous study for a single stage virtual impactor were used to determine the design parameters such as 50% cut-off sizes and dimensions of the two stage virtual impactor. The separation efficiency curve and 50% cut-off Stokes number(cut-off sizes) are not sensitive to the nozzle Reynolds number, but sensitive to the ratio between the minor flow rate and the total flow rate, The measured concentration efficiency was compared with the maximum concentration efficiency determined by the separation efficiencies of the first and the second stages. The differences between the measured and the maximum concentration efficiencies result from the wall loss due to the deposited particles on the internal walls inside the impactor.

Influence of Working Variables in Simplified Gear Shaving Process (단순 기어형상의 셰이빙가공에 있어서 작업 변수의 영향)

  • Lee, K.S.;Jung, J.Y.;Kim, J.H.
    • Transactions of Materials Processing
    • /
    • v.19 no.5
    • /
    • pp.290-295
    • /
    • 2010
  • Shaving technology is one of the significant metal forming technologies which can make the smooth and fine sheared surface of products after shearing process. The sheared surface on the side wall of the cutting edge is very important because it functions as a basic surface for measuring the dimensions of product. Effective sheared surface after shaving can be influenced by several working variables such as shaving allowance, shaving clearance, type of material and profile of cutting edge. The influence of these variables on shaving characteristics was investigated in this study. A cut-off die to make the simplified gear-shaped products was manufactured. Three kinds of sheet metals (AL5052, SPCC and SAPH440) of 3mm thickness were firstly sheared and then shaved for four shaving allowances and three sharing clearances. It was shown through experiments that the optimum working condition to give the maximum effective sheared surface in shaving was found ; Shaving allowance is 0.2mm and Shaving clearance is 0.01mm.

Growth of HgCdTe thin film by the hot-wall epitaxy method (Hot-wall epitaxy 방법에 의한 HgCdTe 박막 성장)

  • 최규상;정태수
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.4
    • /
    • pp.406-410
    • /
    • 2000
  • Using the hot-wall epitaxy method, we grew a $Hg_{1-x}Cd_xTe$ (MCT) thin film in-situ after growing (111) CdTe of 9 $mu \textrm{m}$ as a buffer layer. The value of FWHM of double crystal x-ray diffraction rocking curve was 125 arcsec and the surface morphology was clean with a small roughness of 10 nm. From measuring the photocurrent of the grown MCT thin film, the maximum peak wavelength and the cut-off wavelength were 1.1050 $\mu\textrm{m}$ (1.1220 eV) and 1.2632 $\mu\textrm{m}$ (0.9815 eV), respectively. This peak wavelength corresponds to the peak of the band gap due to the intrinsic transition of the photoconductor. Therefore, the MCT thin film could be used as the photoconducting detector sensing a near-IR wavelength band from 1.0 to 1.6 $\mu\textrm{m}$.

  • PDF

A case study on the selection process of cutoff wall for ground-water using VE/LCC analysis (VE/LCC 기법을 활용한 차수공법 선정사례 연구)

  • Cho Yong-Wan;Chang Jun-Ho;Kim Jin-Man;Ha Jae-In
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.279-291
    • /
    • 2006
  • This study shows decision-making process for selection of cutoff wall on a wastewater treatment project. There are 10 different cut-off wall methods So, we examine the site to gather information for find appropriate methods. After using that information, 10 cutoff wall methods are reviewed for analysis. Through brainstorming, four alternatives are selected for design VE item. Following the standard VE process, we established performance criteria and evaluated function score(F) using questionnaire. The questionnaires, brainstorming and AHP method for weighting on performance criteria and evaluate function score increased the reliability of this selection process. Water Jet method, one of four methods, has the best function score(F=92.71) and the lease construction cost(as cost index 1,000). The value score also highest as 92.7, so we select the method. The result is value innovation type In addition, the authors try to calculate the environmental burden in selection process using LCA. We cannot conduct the full LCA as defined ISO, so perform Simple LCA In LCA result, the cut-off grouting has the least environmental burden as index 9.09E+01 and Water Jet method has following as the second. To selection best method to specific area and purpose, design VE/LCG process used as useful tool and it is needed to develop integrated method that evaluate VEILCC and LCA as one-set process.

  • PDF