• Title/Summary/Keyword: Cut-off Frequency

Search Result 405, Processing Time 0.039 seconds

An experimental study for reduction of B.P.F. noise level of multi-blade fan (다익 송풍기의 이산 주파수 소음 저감을 위한 실험적 연구)

  • 김영찬;이상환
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.2
    • /
    • pp.167-175
    • /
    • 1999
  • B.P.F.(Blade Passing Frequency) levels were measured with the cut-off clearance changes. The velocity inside the scroll, pressure fluctuation at cut-off region, and the scroll surface pressure distribution along the scroll from the cut-off to outlet were measured. With a certain cut-off clearance the improvement of efficiency and attenuation of B.P.F. noise level could be achieved. The measured results of pressure fluctuation and scroll surface pressure distribution showed that the secondary flow inside the scroll increased B.P.F. noise level at the cut-off region as the cut-off clearance got wide.

  • PDF

Analysis of Radio Frequency characteristics for Double Gate MOSFET (Double Gate MOSFET의 RF특성분석)

  • 김근호;고석웅;정학기
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.690-692
    • /
    • 2003
  • In this paper, we have investigated characteristics of radio frequency for double gate MOSFET with 50nm main gate in according to variation of side gate length. We could know the increasement of cut-off frequency as the side gate length is lower. As a result, we could know the most optimum performance characteristics when side gate length was 70nm. In this time, the DG MOSFET of side gate with 70nm has very high cut-off frequency like 41.4GHz.

  • PDF

Surface Elevation Recovery Methods from Pressure Gage for Irregular Waves (불규칙파(不規則波에) 대한 압력식(壓力式) 파고계(波高計)의 적용성(適用性)에 관한 연구(研究))

  • Kwon, Jung Gon;Kang, Ju Bok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.4_1
    • /
    • pp.129-136
    • /
    • 1992
  • A precedure for recovering surface displacement from a time series of pressure measured by a pressure gage in a shallow water (that is, FFTM, LCM. IWM) is investigated with respect to a proper cut-off-frequency of a frequency response function for the accurate recovery of wave height and period. The authors examined the applicability of above mentioned three transformation procedures through field observations and laboratory experiments and the following results are obtained. i) The cut-off-frequency of the frequency response function used in FFTM is deeply depend on both the frequency response of the pressure sensor and the water depth at the sensor. In this study, a relatively accurate surface displacement can be recovered when the frequency response function is cut off at the frequency corresponding to kh=3.0 where k is a wave number at the depth of h. The frequency response function in the region higher than the cut-off-frequency is set constant to be the value at the cut-off-frequency. ii) The transformed surface displacements by LCM are affected by the small waves of short periods included in the measured pressure. It is found that pressure variation whose local frequency is higher than kh=1.5 has to be neglected to recover surface displacement sufficiently. iii) In IWM, the linear pressure response function is usually utilized by multiplying a coefficient N which is a function of the frequency (or kh) and takes a value around unity. However, in this study, a constant value of N(=1.0) gives a relatively accurate recovery of surface displacements.

  • PDF

Identification on Principle of Acoustic Wave Propagation Characteristics in a Gas Pipe (가스 배관 내부의 음파 전달 특성에 관한 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon;Jang, Sang-Yup;Koh, Jae-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.797-804
    • /
    • 2008
  • In the gas supply pipe, the gas leakage caused by the impact of the construct equipment is serious problem. The identification of the impact position is an important issue and an engineering work. For the basic research of this problem, the principle studies for the acoustic wave propagation in a gas pipe are proceeded in this paper. This principal work is based on the identification of the cut-off frequency associated with major modes of the gas pipe theoretically and experimentally The cut-off frequency is confirmed by STFT and cross-correlation function is used to identify the leakage position.

Optimum Ge Profile for Higher Cut Off Frequency of SiGe HBT (SiGe HBT 소자의 높은 차단 주파수 특성을 위한 Ge profile 연구)

  • Kim, Sung-Hoon;Kim, Kyung-Hae;Lee, Hoong-Joo;Ryum, Byung-Ryul;Yi, Jun-Sin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1803-1805
    • /
    • 2000
  • This paper analyzes the effects of Ge profiles shape of SiGe heterojunction bipolar transistors (HBT's) for high frequency application. Device simulations using ATLAS/BLAZE for the SiGe HBT with trapezoidal or triangular Ge profile are carried out to optimize the device performance. An HBT with 15% triangular Ge profile shows higher cut-off frequency and DC current gain than that with 19% trapezoidal Ge profile. The cut-off frequency and BC gain are increased from 42GHz to 84GHz and from 200 to 600, respectively.

  • PDF

Association between False Positive, False Negative, High-Background Cases and Humidity in One Lambda LABTypeTM HLA-DR Typing (One Lambda LABTypeTM을 이용한 HLA- DR Typing시 나타나는 위양성과 위음성, High-Background 사례와 검사실 습도의 관계분석)

  • Hyang Son AN;Minsung SOHN
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.3
    • /
    • pp.132-142
    • /
    • 2023
  • Human leukocyte antigen (HLA) typing was performed in the diagnostic immunology laboratory of the Seoul National University Hospital. Among 611 HLA-DR tests, specific bead reactions suspected of being false positive and false negative in Lot 20 reagents were found. Therefore, we aimed to identify the factors causing cut-off corrections by examining cases where cut-off corrections were not made for 533 test results and cases where cut-off corrections were made for 78 cases after the cut-off corrections of specific beads. Frequency analysis was conducted to verify the demographic characteristics, and descriptive statistics were used to assess the humidity in the laboratory as a variable. Cross-tabulation was done to examine the association between cut-off corrections and demographic characteristics. Independent samples t-tests were conducted to verify the difference in humidity based on cut-off corrections. Finally, logistic regression analysis was conducted to examine the relationship between humidity levels and the rate of cut-off corrections, and results showed as the humidity level in the laboratory highs, the number of cut-off corrections decreased by a factor of 0.986. This suggests cut-off corrections rate increases when the humidity lowers. Therefore, it indicates that humidity in the laboratory is also a factor that affects HLA typing results.

Comparative Evaluation of Resolution according to Frequency Change for SPECT (단일광자방출전산화단층촬영(SPECT)을 위한 주파수 변동에 따른 분해능 비교평가)

  • Kim, Sung-Chul;Park, Soo-Yeun;Cho, Young-Kwon;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.322-331
    • /
    • 2009
  • In clinical SPECT, FWHM provides quality information of the images obtained under different observing conditions. Therefore, the purpose of this study was to determine the optimum cut off level with comparison of FWHM according to cut off levels in each filter - Band limited, Sheep-Logan, Hanning, Hamming, Low pass cosine, Parazen and Butterworth filter in a SPECT camera. I recorded images along the X, Y, Z-axis with 99mTcO4 point source and measured FWHM with profile curves. In conclusion, all filters showed the longest figures of FWHM with cut off level 0.4, which has the worst image resolution. The images with cut off level 0.7 showed best image resolution. The shortest average of FWHM in MS2 was $11.07\pm0.07mm$ using the Butterworth filter, in MS3 it was $8.44\pm0.19mm$ through using the Hanning filter.

Identification on Principle of Acoustic Wave Propagation in a Gas Duct (가스 파이프 내부의 음향 전파 특성에 관한 연구)

  • Kim, Min-Soo;Lee, Sang-Kwon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1100-1105
    • /
    • 2007
  • In the gas supply duct, the gas leakage caused by the impact of the construct equipment is serious problem. The identification of the impact position is an important issue and an engineering work. For the basic research of this problem, the principle studies for the acoustic wave propagation in a gas duct are proceeded in this paper. This principal work is based on the identification of the cut-off frequency associated with major modes of the gas duct theoretically and experimentally. The cut-off frequency is confirmed by STFT and cross-correlation function is used to identify the leakage position.

  • PDF

A Study on Low-Pass Filter using All-Pass Filter of Parallel Structure (병렬 구조의 올패스 필터를 사용한 LPF에 관한 연구)

  • 김승영;김남호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.3
    • /
    • pp.533-541
    • /
    • 2001
  • In this paper, we proposed lowpass filter using all-pass sums of flat delay characteristics. this filter consisted of all-pass filter of parallel structure, the general analog filter is impossible to adjust the phase and the delay, using the Proposed filter, it has advantage to adjust them. And, we compared and analyzed this filter with passband width and magnitude characteristics, and the relation of group delay characteristics and cut-off frequency. Also, in order to obtain desired cut-off frequency, forming the weighing, we obtained desired cut-off frequency and group delay characteristics.

  • PDF

A New Broadband Microstrip-to-SIW Transition Using Parallel HMSIW

  • Cho, Dae-Keun;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.2
    • /
    • pp.171-175
    • /
    • 2012
  • In this work, a new microstrip-to-substrate integrated waveguide (SIW) transition using the parallel half-mode substrate integrated waveguide (HMSIW) is proposed. The proposed transition consists of three sections : a microstrip, parallel HMSIWs, and an SIW. By inserting the parallel HMSIWs section between the microstrip section and the SIW section, the proposed transition can improve the return loss characteristics of the near cut-off frequency because the HMSIWs section has a lower cut-off frequency than the SIW section (8.6 GHz). The lower cut-off frequency is achieved through gradual electromagnetic field mode changes for a low reflection. The measured return loss is less than 20 dB in the of 9.1~16.28 GHz freqeuncy range for the back-to-back transition. The measured insertion loss is within 1.6 dB for the back-to-back transition. The proposed transition is expected to play an important role in wideband SIW circuits fed by a microstrip.