• Title/Summary/Keyword: Cut Out Switch

Search Result 22, Processing Time 0.034 seconds

An Experimental Study on the Noise Reduction and the Feasibility of Short Current of a Silencer for a High Voltage COS Fuse (고전압 COS 퓨즈용 소음기의 소음저감 및 전류차단 성능에 관한 실험적 연구)

  • Lee, Dong-Hoon;Song, Hwa-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.7
    • /
    • pp.783-789
    • /
    • 2008
  • This experimental study describes the noise reduction and the feasibility of short current of a silencer for a high voltage COS(cut out switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current, the strong impulse noise over 150 dB(A) is generated. For the purpose of the reduction of impulse noise, in this study, the diffuser type and the reactive type silencers have been designed and tested, respectively. And also the electrical test on the short current is performed. From the experimental results, the well designed reactive type silencer has been shown to have the noise reduction of about 20 dB(A). It has been found that the feasibility of short current for the COS fuse is closely related to the porosity of the silencer.

Embedded System Design with COS LoRa technology (COS LoRa 기반의 임베디드 시스템 설계)

  • Hong, Seonhack;Cho, Kyungsoon;Yoon, Jinseob
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 2018
  • It is the approach of embedded system design that analyzes COS(Cut Out Switch) failure in the power distribution and an instantaneous breakdown of power distribution supply could cause the weakness of industrial competence and therefore we need to feed the stable power distribution with developing the technology of open-source embedded system. In this paper, we apply the LoRa technology which is the Internet of Things(IoT) protocol for low data rate, low power, low cost and long range sensor applications. We designed the hardware and software architecture setup and experimented the embedded system with network architecture and COS monitoring system including accelerometer for detecting the failure of distribution line and sensing the failure of its fuse holder by recognizing the variation and collision and afterwards sending the information to a gateway. With experimenting we designed the embedded platform for sensing the variation and collision according to the COS failure, monitoring its fuse holder status and transferring the information of states with LoRa technology.

COS MEMS System Design with Embedded Technology (Embedded 기술을 이용한 COS MEMS 시스템 설계)

  • Hong, Seon Hack;Lee, Seong June;Park, Hyo Jun
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.405-411
    • /
    • 2020
  • In this paper, we designed the COS MEMS system for sensing the falling detection and explosive noise of fuse link in COS (Cut Out Switch) installing on the power distribution. This system analyzed the failure characteristics and an instantaneous breakdown of power distribution. Therefore, our system strengths the industrial competence and guaranties the stable power supply. In this paper, we applied BLE (Bluetooth Low Energy) technology which is suitable protocol for low data rate, low power consumption and low-cost sensor applications. We experimented with LSM6DSOX which is system-in-module featuring 3 axis digital accelerometer and gyroscope boosting in high-performance mode and enabling always-on low-power features for an optimal motion for the COS fuse holder. Also, we used the MP34DT05-A for gathering an ultra-compact, low power, omnidirectional, digital MEMS microphone built with a capacitive sensing element and an IC interface. The proposed COS MEMS system is developed based on nRF52 SoC (System on Chip), and contained a 3-axis digital accelerometer, a digital microphone, and a SD card. In this paper of experiment steps, we analyzed the performance of COS MEMS system with gathering the accelerometer raw data and the PDM (Pulse Data Modulation) data of MEMS microphone for broadcasting the failure of COS status.

A Study on Possibility of Detection of Insulators' Faults by Analyses of Radiation Noises from Insulators (애자의 소음 분석을 통한 애자 고장 탐지 가능성 연구)

  • Park, Kyu-Chil;Yoon, Jong-Rak;Lee, Jae-Hun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.822-831
    • /
    • 2009
  • The porcelain insulators are important devices, that are used to isolate electrically and hold mechanically in the high-voltage power transmission systems. The faults of the insulators induce very serious problems to the power transmission line. In this paper, we introduce techniques for fault detections of insulators by acoustic radiation noises from them. We measured radiation noises from normal state insulators and fault state insulators. The used insulators were two different type porcelain insulators, a cut out switch, two different type line posters, and a lightning arrester. Each results was compared each other in time domain, frequency domain and filter banks' outputs. We found the possibility of detection of insulators' faults and also suggested techniques for fault detections.

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

Impact of Pay TV Market Structure and Competition on Digital Switch Over of Cable TV (유료방송의 시장구조와 경쟁이 케이블 TV의 디지털 전환에 미치는 영향)

  • Do, Joonho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.145-153
    • /
    • 2016
  • Cable TV with largest subscription base in pay TV market has difficulty in managing the task of digital switch over. This study analyzed the factors in delay of cable TV switch over and examined the impact of pay TV market structure and competition. The delaying factors turned out to be the lack of incentives and resources of cable TV operators, insufficient policy measures and acceptance tolerance issues of subscribers. Since cable TV operators with monopolistic status in pay TV market had continuous profit from analog service, they were not responsive to digital switch over which requires additional investment. Policy measures including support for the low income household and mandatory cut-off point for stopping analog broadcasting. Subscriber's willingness to accept digital broadcasting in terms of price sensitivity and preference for convenient operation also played a role. Introduction of IPTV in pay TV market influenced the speed of digital switch over of cable TV operators. MSOs with economies of scale showed higher digital switch over rate than independent SO.

Noise Reduction Performance of a Reactive type Silencer with Perforated Panels (다공판이 내장된 반사형 소음기의 소음저감 성능)

  • Lee, Sun-Ki;Lee, Young-Chul;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

Research and development of advanced COS for anti-contamination (염진해 특성이 향상된 COS의 개발에 관한 연구)

  • Kim, L.S.;Han, D.H.;Ahn, M.S.;Cho, H.G.;Kang, D.P.;Hwang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1599-1602
    • /
    • 1994
  • Recently, failure of COS(cut out switch) due to contamination has been increased. This paper is on the development of the contamination COS. 1 We designed a porcelain insulator of alternate shed for anti-contamination COS. 2 The COS was coated with HVIC(silicone) to improve resistivity to contamination. 3 The FOV characteristics of COS were examined to obtain dry FOV, wet FOV and contamination FOV.

  • PDF

The Study on the Dry and Wet Flashover Voltages of the Artificially Salt Contaminated Distribution Facilities (인공오손에 따른 배전기자재의 건조 및 습윤 섬락에 관한 연구)

  • Kim, Chan-Young;Kim, Dong-Myung;Kwon, Tae-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.487-488
    • /
    • 2008
  • The dry and wet flashover characteristics on the contaminated distribution facilities was investigated. The test were carried out on the suspension insulator, line post insulator, lightning arrester, cut off switch, etc. In the dry state, the flashover voltages of facilities contaminated with B, C, D classes are similar to the non-contaminated ones. However, in the wet state, the flashover voltages of facilities contaminated with B, C, D classes are decreased. The flashover voltages of some few facilities show under the standard value. This results indicate that the high humidity may cause the flashover on distribution facilities.

  • PDF

The Study for change plane to apply CBTC(Communication Based Train Control) on the subway (통신을 이용한 열차제어시스템의 기존 도시철도 적용을 위한 절체방안연구)

  • Kim, You-Ho;Lee, Soo-Hwan;Yoo, Jong-Cheon;Lee, Young-Hoon;Baek, Jong-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.365-367
    • /
    • 2003
  • In this study, we studied the change plan essentially used for improving the existing railroad signal system. For mixed installation with the existing equipment by introducing new equipment in the city railroad currently operated, it is required to establish a plan depending on the change and to present a plan for change. For the change, since it is necessary to classify ground equipment and onboard equipment and change must be carried out considering performance and functions of each equipment, we classified and studied each equipment for plans of change.

  • PDF