• 제목/요약/키워드: Current-voltage characteristics

검색결과 3,701건 처리시간 0.037초

Donor 첨가량과 시편두께에 따른 PTC 세라믹스의 전류-전압 특성 (Current-voltage Characteristics of PTC Ceramics by Changing Donor Concentration and Specimen Thickness)

  • 한응학;강영석;박순자
    • 한국세라믹학회지
    • /
    • 제28권8호
    • /
    • pp.619-625
    • /
    • 1991
  • The current-voltage characteristics of the semiconducting BaTiO3 ceramics are measured in the range of 0.01∼100 Volt. Non ohmic behavior was observed above Tc. This behavior is not dependent on specimen thickness and is not observed at the incomplete semiconducting sepcimen. From this experiment, non-ohmic behavior of PTC is attributed to Heywang's potential barrier not to space change limited current. In the low voltage range, current-voltage characteristics of PTC ceramics can be explained by Heywang model.

  • PDF

Erbium 실리사이드를 이용하여 제작한 n-형 쇼트키장벽 관통트랜지스터의 전기적 특성 (Characteristics of Erbium silicided n-type Schottky barrier tunnel transistors)

  • Moongyu Jang;Kicheon Kang;Sunglyul Maeng;Wonju Cho;Lee, Seongjae;Park, Kyoungwan
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.779-782
    • /
    • 2003
  • The theoretical and experimental current-voltage characteristics of Erbium silicided n-type Schottky barrier tunneling transistors (SBTTs) are discussed. The theoretical drain current to drain voltage characteristics show good correspondence and the extracted Schottky barrier height is 0.24 eV. The experimentally manufactured n-type SBTTs with 60 nm gate lengths show typical transistor behaviors in drain current to drain voltage characteristics. The drain current on/off ratio is about 10$^{5}$ at low drain voltage regime in drain current to gate voltage characteristics.

  • PDF

변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 (Current Limiting and Voltage Sag Compensation Characteristics of Flux-Lock Type SFCL Using a Transformer Winding)

  • 고석철
    • 한국전기전자재료학회논문지
    • /
    • 제25권12호
    • /
    • pp.1000-1003
    • /
    • 2012
  • The superconducting fault current limiter (SFCL) can quickly limit the fault current shortly after the short circuit occurs and recover the superconducting state after the fault removes and plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the flux-lock type SFCL with an isolated transformer, which consists of two parallel connected coils on an iron core and the isolated transformer connected in series with one of two coils, has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. The current limiting and the voltage sag compensating characteristics of a SFCL using a transformer winding were analyzed. Through the analysis on the short-circuit tests results considering the winding direction of two coils, the SFCL designed with the additive polarity winding has shown the higher limited fault current than the SFCL designed with the subtractive polarity winding. It could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

병렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 분석 (Analysis on Current Limiting and Voltage Sag Compensating Characteristics of a SFCL using Magnetic Coupling of Parallel Connected Two Coils)

  • 임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.159-163
    • /
    • 2010
  • The superconducting fault current limiter (SFCL) plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the SFCL using magnetic coupling of two coils with parallel connection has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. In this paper, the current limiting and the voltage sag compensating characteristics of a SFCL using magnetic coupling of parallel connected two coils were analyzed. Through the analysis on the experimental results considering the winding direction of two coils, the SFCL designed with the additive polarity winding was shown to have the higher limited fault current than the SFCL designed with the subtractive polarity winding. In addition, it could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

CVD증착에 의한 인버티드 스태거형 TFT의 전압 전류 특성 (Current and voltage characteristics of inverted staggered type amorphous silicon thin film transistor by chemical vapour deposition)

  • 이우선;박진성;이종국
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권10호
    • /
    • pp.1008-1012
    • /
    • 1996
  • I-V, C-V characteristics of inverted staggered type hydrogenerated amorphous silicon thin film transistor(a-Si:H TFT) was studied and experimentally verified. The results show that the log-log plot of drain current increased by voltage increase. The saturated drain current of DC output characteristics increased at a fixed gate voltage. According to the increase of gate voltage, activation energy of electron and the increasing width of Id at high voltage were decreased. Id saturation current saturated at high Vd over 4.5V, Vg-ld hysteresis characteristic curves occurred between -15V and 15V of Vg. Hysteresis current decreased at low voltage of -15V and increased at high voltage of 15V.

  • PDF

제어 방식에 따른 20 W급 LED Converter 설계 및 분석 (Design and Analysis of 20 W Class LED Converter Considering Its Control Method)

  • 정영기;김성현;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제25권1호
    • /
    • pp.53-57
    • /
    • 2012
  • In this paper, by designing 20 W class driving circuit for driving high-power LED (Light Emitting Diode), we are going to comparatively carry out the analysis of characteristics for power circuit according to each design method. In this case, 200 V 60 Hz was performed as input data. The electrical characteristics such as voltage, current and ripple are checked for constant current circuit and constant voltage circuit in the LED module. In addition, as the ripple has an influence on illumination of LED light, low temperature working (-20 [$^{\circ}C$]) and high temperature working(80 [$^{\circ}C$]) are measured to make sure the ripple characteristics in accordance with temperature. In low temperature operation -20 [$^{\circ}C$] measurements, both constant current circuit and constant-voltage circuit were less impacted on input fluctuation, whereas in the high temperature operation 80 [$^{\circ}C$], current voltage in constant voltage circuit was surge after 430 [hour]. Voltage current ripple of constant current circuit was much less than constant voltage circuit, therefore we can show that constant current circuit is more stable.

교류측 전압 및 전류 센서가 없는 3상 Z-소스 PWM 정류기의 퍼지-PI 제어 (A Fuzzy-PI Control Scheme of the Three-Phase Z-Source PWM Rectifier without AC-Side Voltage and Current Sensors)

  • 한근우;정영국;임영철
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.767-781
    • /
    • 2013
  • In this paper, we proposes the AC input voltage and current sensorless control scheme to control the input power factor and DC output voltage of the three-phase Z-source PWM rectifier. For DC-link voltage control which is sensitive to the system parameters of the PWM rectifier, fuzzy-PI controller is used. Because the AC input voltage and current are estimated using only the DC-link voltage and current, AC input voltage and current sensors are not required. In addition, the unity input power factor and DC output voltage can be controlled. The phase-angle of the detected AC input voltage and estimated voltage, the response characteristics of the DC output voltage according to the DC voltage references, the FFT results of the estimated voltage and current, efficiency, and the response characteristics of the conventional PI controller and fuzzy-PI controller are verified by PSIM simulation.

Nanosheet FET와 FinFET의 도핑 농도에 따른 전류-전압 특성 비교 (Comparison of Current-Voltage Characteristics by Doping Concentrations of Nanosheet FET and FinFET)

  • 안은서;유윤섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.121-122
    • /
    • 2022
  • 본 논문은 Nanosheet FET(NSFET)와 FinFET의 구조를 갖는 소자 성능을 조사하기 위해서 3차원 소자 시뮬레이터를 이용하여 시뮬레이션한 결과를 소개한다. NSFET와 FinFET의 채널 도핑 농도에 따른 전류-전압 특성을 시뮬레이션하였고, 그 전류-전압 특성으로부터 추출한 문턱전압, 문턱전압이하 기울기 등의 성능을 비교하였다. NSFET이 FinFET보다 채널 도핑 농도에 따른 전류-전압 특성에서 드레인 전류가 더 많이 흐르며 더 높은 문턱전압을 갖는다. 문턱전압이하 기울기는 NSFET가 FinFET보다 더 가파른 기울기를 갖는다.

  • PDF

Nanosheet FET와 FinFET의 전류-전압 특성 비교 (Comparison of Current-Voltage Characteristics of Nanosheet FET and FinFET)

  • 안은서;유윤섭
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.560-561
    • /
    • 2022
  • 본 논문은 Nanosheet FET(NSFET)와 FinFET의 소자 성능을 3차원 소자 시뮬레이션을 통하여 다양한 구조의 NSFET와 FinFET의 소자 시뮬레이션을 한다. NSFET와 FinFET의 전류-전압 특성을 시뮬레이션하였고, 그 전류-전압 특성으로부터 추출한 문턱전압, 문턱전압이하 기울기 등의 성능을 비교하였다. NSFET이 FinFET보다 전류-전압 특성에서 드레인 전류가 더 많이 흐르며 더 높은 문턱전압을 갖는다. 문턱전압이하 기울기는 NSFET와이 FinFET보다 더 가파른 기울기를 갖는다.

  • PDF

모의전력계통에 적용된 자속구속형 초전도 전류제한기의 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of a Fault-lock Type SFCL Applied into a Simulated Power System)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제24권2호
    • /
    • pp.141-146
    • /
    • 2011
  • When the current of the superconducting element exceeds its critical current by the fault occurrence, the quench of the high-$T_C$ superconducting fault current limiter (HTSC) comprising the flux-lock type superconducting fault current limiter (SFCL) occurs. Simultaneously, the magnetic flux in the iron core induces the voltage in each coil, which contributes to limit the fault current. In this paper, the fault current limiting characteristics of the flux-lock type SFCL as well as the load voltage sag suppressing characteristics according to the flux-lock type SFCL's winding direction were investigated. To confirm the fault current limiting and the voltage sag suppressing characteristics of the this SFCL, the short-circuit tests for the simulated power system with the flux-lock type SFCL were carried out. The flux-lock type SFCL designed with the additive polarity winding was shown to perform more effective fault current limiting and load voltage sag suppressing operations through the fast quench occurrence right after the fault occurs and the fast recovery operation after the fault removes than the flux-lock type SFCL designed with the subtractive polarity winding.