• 제목/요약/키워드: Current vector field

검색결과 173건 처리시간 0.024초

자속관측기를 이용한 유도 전동기 자계 Orientation형 센서리스 벡터제어 (Field Oriented Vector Control of Induction Motor without Speed Sensor Using Flux Observer)

  • 손의식;홍순일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권1호
    • /
    • pp.100-107
    • /
    • 2003
  • This study was to control magnetic field orientation-typed sensorless vector control by applying the theory of a rotor flux observer to drive an induction motor. This research suggested a new speed estimation method that estimates speed with the rotor flux obtained by using a flux observer and the variable of state current detected by a current sensor without a speed sensor. Because the speed estimation method is independent from the motor constants, it is not necessary to control the gain of the parameters and the algorithm is simple. In the findings of the study, the researcher was convinced of the control function and the possibility of realization in the simulation experiment of sensorless vector control system by using DSP(Digital Signal Prosessor).

Speed Sensorless Vector Control for AC servo Motor Using Flux observer

  • Hong, Jeng-pyo;Kwon, Soon-Jae;Hong, Soon-Ill
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.185-191
    • /
    • 2004
  • This study describes the scheme of vector drive system without speed sensor for AC servo motor using theory of a flux observer and based on the field oriented vector control. The new method of speed estimation is presented from operate with the position and magnitude of the secondary flux which obtain from the voltage reference and detected current. As the estimated speed is settled by the flux and the machine-specific parameters. this method don't need to adjust the gain of the parameter. Based on the derived theory for vector control. the scheme for sensorless vector drive of AC servo motor is designed and realized. And the experiment verifies it passable to realize the sensorless vector drive based on a field-oriented type.

퍼지 알고리즘을 이용한 유도전동기 간접벡터제어기의 설계와 엘리베이터 속도제어 시스템의 응용 (Design of Indirect Vector Controller of Induction Motor using Fuzzy Algorithm and apply to the Speed Control System of Elevator)

  • 경제문;김훈모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.110-113
    • /
    • 2000
  • In general, speed control method of the elevator system has used motor pole change type or motor primary voltage control type. But it will change to vector control type in order to increase it's reliability, riding comfort and decrease material cost. It is the conception of vector control type in order to increase it's reliability, riding comfort and decrease material cost. It is the conception of vector control that primary current of the induction motor be controlled independently with magnetizing current(field current of DC motor) and torque current(armature current of DC motor). In this paper, by analyzing the effect of the time constant variation of rotor of the induction motor on the slip frequency type indirect vector control, a drive system for the motor will be constructed using a fuzzy slip frequency type indirect vector controller with fuzzy control method for estimating the vector time constant in the slip frequency type indirect vector control. The goal of this study is to enabling even more efficient speed control by constructing on elevator driver based on the newly developed drive system.

  • PDF

감쇠회전 벡터법과 상 분리법에 의한 농형 유도 전동기의 과도현상해석 (Analysis of the Transient Phenomena of a Squirrel-Cage Induction Motor by means of the Spiral Vector method and the Phase Segregation method)

  • 정종호;이은웅;최재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.644-646
    • /
    • 2000
  • An induction motor can be controlled like a separately excited do motor by field oriented control(or vector control). In vector control, Because the transformation of the stator's 3-phase current into two orthogonal current is required. the control scheme is complicated. But, Yamamura proposed a field acceleration method(FAM) without the phase transformation. FAM simplify an implementation control scheme for induction motors. In this paper, the analysis of transient phenomena of a squirrel-cage induction motor was achieved by the spiral vector method and the phase segregation method. It simplified control schemes more than those of vector control.

  • PDF

유도전동기의 강인 제어를 위한 뉴로-퍼지 설계 (Design of neuro-fuzzy for robust control of induction motor)

  • 송윤재;강두영;김형권;안태천
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 춘계학술대회 학술발표 논문집 제14권 제1호
    • /
    • pp.454-457
    • /
    • 2004
  • In this paper, control method proposed for effective speed control of the induction motor indirect vector control. For the induction motor drive, indirect vector control scheme that controls torque current and flux current of the stator current independently so that it can have improved dynamics. Also, neuro-fuzzy algorithm employed for torque current control in order to optimal speed control The proposed neuro-fuzzy algorithm can be applied to the precise speed control of an induction motor drive system or the field of any other power systems.

  • PDF

3상 영구자석형 동기전동기의 구동을 위한 벡터 제어 (Vector Control for Three Phase Permanent Magnet Synchronous Motor Drive System)

  • 문재은;이태훈;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 추계학술대회
    • /
    • pp.193-194
    • /
    • 2017
  • This paper proposes a current control method in synchronous coordinate for vector control of PMSM (Permanent Magnet Synchronous Motor). In order to control the PMSM by MTPA(Maximum Torque per Ampere), it is necessary to generate the rotating magnetic field to be $90^{\circ}$ with the magnetic field of the rotor, and the current control is necessary. To apply the current control to PMSM, the phase of the current command is also changed in accordance with the change of the position of the motor rotor. In this paper, the control of PMSM is performed through simulation using DC current command in synchronous coordinate system.

  • PDF

지자기 기반 실내 위치 추정을 위한 지자기 벡터 보정법 (Vector Calibration for Geomagnetic Field Based Indoor Localization)

  • 손원준;최린
    • 한국차세대컴퓨팅학회논문지
    • /
    • 제15권3호
    • /
    • pp.25-30
    • /
    • 2019
  • 지자기 벡터는 센서가 바라보고 있는 방향에 따라 그 값이 달라지는 특성이 있다. 본 논문에서는 그런 문제를 최소화하여 지자기 기반 실내 위치 추정에 사용될 수 있도록 지자기 벡터 보정법을 제안한다. 지자기 기반 실내 위치 추정에서 사용되는 핑거프린팅 기법은 자기장 지도와 현재 위치에서의 자기장 값을 매칭하여 위치를 추정해낸다. 이때, 자기장 센서는 사용자의 이동 방향에 따라 읽어 들이는 자기장 벡터 값이 달라지기 때문에 위치 추정 정확도가 낮아진다. 이를 해결하기 위해 많은 연구들은 자기장 벡터 크기를 사용하지만, 이는 지문의 고유성을 감소시킨다. 따라서 본 논문에서는 지문의 고유성을 유지할 수 있는 자기장 벡터를 그대로 사용하되, 벡터 크기처럼 사용자의 이동방향에 영향을 받지 않도록 벡터 값을 보정하는 방법을 제안한다. 임의의 방향으로 걸어본 결과, 본 연구에서 제안된 보정법을 사용하면 자기장 지도와의 매칭 정확도가 높아지는 것을 확인하였다.

A New Method for Coronal Force-Free Field Computation That Exactly Implements the Boundary Normal Current Density Condition

  • 이시백;전홍달;이중기;최광선
    • 천문학회보
    • /
    • 제44권2호
    • /
    • pp.71.3-71.3
    • /
    • 2019
  • Previously we developed a method of coronal force-free field construction using vector potentials. In this method, the boundary normal component of the vector potential should be adjusted at every iteration step to implement the boundary normal current density, which is provided by observations. The method was a variational method in the sense that the excessive kinetic energy is removed from the system at every iteration step. The boundary condition imposing the normal current density, however, is not compatible with the variational procedure seeking for the minimum energy state, which is employed by most force-free field solvers currently being used. To resolve this problem, we have developed a totally new method of force-free field construction. Our new method uses a unique magnetic field description using two scalar functions. Our procedure is non-variational and can impose the boundary normal current density exactly. We have tested the new force-free solver for standard Low & Lou fields and Titov-Demoulin flux ropes. Our code excels others in both examples, especially in Titov-Demoulin flux ropes, for which most codes available now yield poor results. Application to a real active region will also be presented.

  • PDF

Calculation of Magnetic Field for Cylindrical Stator Coils in Permanent Magnet Spherical Motor

  • Li, Hongfeng;Ma, Zigang;Han, Bing;Li, Bin;Li, Guidan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2158-2167
    • /
    • 2018
  • This paper analyzed the magnetic field produced by the cylindrical stator coils of permanent magnet spherical motor (PMSM). The elliptic equations about the vector magnetic potential were given. Given that the eddy current effects are neglected, the magnet field of the PMSM is regarded as irrotational field, which can be calculated by scalar magnetic potential. The current density of cylindrical stator coil was proposed based on the definition of current density. The expression of current density of stator coil was obtained according to the double Fourier series decomposition and spherical harmonic functions. Then the magnetic flux density for scalar magnetic potential was derived. Further, the influence of different parameters on radial flux density was also analyzed. Finally, the results by the analytical method in this paper were validated by finite element analysis (FEA).

산업현장에서 벡터제어용 유도전동기의 오프라인 파라미터 추정 (Off-line parameter Estimation of Induction Motors for Vector Control in Industrial Field)

  • 권병기;박가우;신원창;조응상;이진섭;최창호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1998
  • Parameter estimation of induction motor for vector control presented in this paper can be easily implemented and applied to inverters in the industrial field, because it needs no additional hardware such as voltage sensor and measuring equipment. At first, the stator resistance including switching loss of inverter is measured by simple voltage-current equation. Next, in pre-magnetization of machine by imposing the d-axis constant field-current, q-axis torque current is forced to the machine until its speed feedback reachs to pre-defined level of speed limit. At this time, we can measure the rotor time-constant by decreasing the distorted output-voltage of inverter. At last, stator inductance, transient inductance, and moment of inertia can be measured by the relationship of output voltage, output torque and speed feedback. The validity and usufulness of this method is verified by experimental results.

  • PDF