• 제목/요약/키워드: Current harmonic

검색결과 1,338건 처리시간 0.029초

단상 계통연계 인버터를 위한 새로운 고조파 보상법 (A Novel Harmonic Compensation Method for the Single Phase Grid Connected Inverters)

  • 칸 아마드 레이안;아쉬라프 모하마드 노만;최우진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.144-146
    • /
    • 2018
  • In order to meet the harmonics standards such as IEEE 519 and P1547 the output quality of a grid connected inverter should satisfy a certain level of Total Harmonic Distortion (THD) value. However, the output quality of an inverter gets degraded due to the grid voltage harmonics, the dead time effects and the nonlinearity of the switches, which all contributes to a higher THD value of the output. In order to meet the required THD value for the inverter output under the distorted grid condition the use of harmonic controller is essential. In this paper a novel feedforward harmonic compensation method is proposed in order to effectively eliminate the low order harmonics in the inverter current to the grid. In the proposed method, unlike the conventional harmonic control methods, the hamonic components are directly compensated by the feedforward terms generated by the PR controller with the grid current in the stationary frame. The proposed method is simple in implementation but powerful in eliminating the harmonics from the output. The effectiveness of proposed method is verified through the PSIM simulation and the experiments with a 5kW single phase grid connected inverter.

  • PDF

단상 계통연계 인버터를 위한 개선된 고조파 보상법 (An Improved Harmonic Compensation Method for a Single-Phase Grid Connected Inverter)

  • 칸 레이안;최우진
    • 전력전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.215-227
    • /
    • 2019
  • Grid-connected inverters should satisfy a certain level of total harmonic distortion (THD) to meet harmonics standards, such as IEEE 519 and P1547. The output quality of an inverter is typically degraded due to grid voltage harmonics, dead time effects, and the device's turn-on/turn-off delay, which all contribute to increasing the THD value of the output. The use of a harmonic controller is essential to meet the required THD value for inverter output under a distorted grid condition. In this study, an improved feedforward harmonic compensation method is proposed to effectively eliminate low-order harmonics in the inverter current to the grid. In the proposed method, harmonic components are directly compensated through feedforward terms generated by the proportional resonant controller with the grid current in a stationary frame. The proposed method is simple to implement but powerful in eliminating harmonics from the output. The effectiveness of the proposed method is verified through simulation using PSIM software and experiments with a 5 kW single-phase grid-connected inverter.

6고조파 주입 PWM을 이용한 3상 승압형 컨버터 고조파저감 (Harmonic Reduction in Three-Phase Boost Converter with Six Harmonic Injected PWM)

  • 이정훈;김재문;안정준;이정호;원충연;정동효
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.327-332
    • /
    • 1999
  • In this paper, six harmonic injection PWM method for reducing total harmonic distortion in single switch three phase discontinuous conduction mode boost converter is presented. In the proposed method, periodic six harmonic voltage is injected in the control circuit to vary the duty ratio of the converter switch within a line cycle so that the fifth order harmonic of the input current is reduced. Experimental results are verified by converter operating at 400V/6kW with three phase 140V~220V input.

  • PDF

피뢰기 열화진단에 있어 전원 고조파의 영향과 보정에 관한 연구 (A Study on the Influence of Harmonics in Power System Voltage on Arrester Diagnostics and its Compensation)

  • 김일권;송재용;한주섭;길경석;류길수;조한구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권11호
    • /
    • pp.493-497
    • /
    • 2005
  • This paper dealt with the influence of harmonic voltages on arrester diagnostics and its compensation method by using a designed Pspice arrester model. A pure sinusoidal voltage and its 3$^{rd}$ harmonic voltage were applied to the model, and the leakage current components were analyzed. The simulation results have shown that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. In this paper, an approximated 5$^{th}$ order polynomial formula by the Least-Square-Technique was derived, and correction factors which compensate the error caused by the 3$^{rd}$ harmonic voltage were calculated.

A Multi-bit VCO-based Linear Quantizer with Frequency-to-current Feedback using a Switched-capacitor Structure

  • Park, Sangyong;Ryu, Hyuk;Sung, Eun-Taek;Baek, Donghyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권3호
    • /
    • pp.145-148
    • /
    • 2015
  • In this letter, we present a new linearization method for a voltage controlled oscillator (VCO)-based quantizer in an analog-to-digital converter (ADC). The nonlinearity of the VCO generates unwanted harmonic spurs and reduces the signal-to-noise and distortion ratio (SNDR) of the VCO-based quantizer. This letter suggests a frequency-to-current feedback method to effectively suppress harmonic distortion. The proposed method decreases the harmonic spurs by more than 53 dB. And a VCO-based quantizer employing the proposed linearization method achieves a high SNDR of 74.1 dB.

Goertzel 알고리즘을 이용한 새로운 단독운전 방지 기법 (A novel anti-islanding method using Goertzel Algorithm)

  • 원동조;김재형;김준구;원충연;이태원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.299-301
    • /
    • 2009
  • In this paper, a novel anti-islanding method of DC-AC single phase inverter is proposed. The inverter injects a little harmonic current with the output current of a PCS(Power Conditioning System). When the islanding condition is occurred, the voltage harmonic components appear on the output voltage of the PCS due to the injection of a little harmonic current. So, the PCS detects the voltage harmonic components using the Goertzel algorithm, and then the PCS decides that the islanding condition is occurred. When the PCS recognizes the islanding condition, the PCS are stopped. The proposed a novel anti-islanding method is analyzed, and its validity is proven through simulation.

  • PDF

전압형 PWM 컨버터를 이용한 교류 전력필터 (AC Power Filter Using Voltage-Source PWM Converter)

  • 김한성;최규하;이제필;전호철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.422-425
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, also the experimental results are shown to verify the theory proposed in this paper.

  • PDF

고속전철용 단상능동필터의 기준고조파전류 발생 방법 (Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives)

  • 성기석;송중호;최익;최주엽;김광배;김권호;임묘택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.338-341
    • /
    • 1999
  • PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.

  • PDF

부스트컨버터의 고조파저감을 위한 스위칭 기법에 관한 연구 (A study On the Switching Technique of Boost Converter for Harmonic Reduction)

  • 손진근;추순남;김용혁;이상철;이복용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.74-78
    • /
    • 2000
  • In this paper a switching control circuit for shaping the line current and reducing the total harmonics distortion in the boost converter is presented. To solve the problems of performance degradation due to pulse waveform in the input current, the boost converter in which the harmonic distortion in the input current is reduced using a 3th harmonic-injected PWM is proposed. Finally, Simulation and experimental results of boost converter with 5[kHz] switching frequency are presented and correction of power factor and reduction of total harmonic distortion was established.

  • PDF

저압 시스템에서 비선형 부하의 사용에 따른 고조파 전류 해석 (Analysis of harmonics current using non-linear load at low voltage system)

  • 김종겸;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.13-16
    • /
    • 2001
  • This paper describes the problems associated with the use of PWM ASDs to drive induction motors. A major effect of harmonic voltages and currents in induction motors is increased heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency, and can also affect the torque developed. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current. Measurement. results show that additional operation of linear load at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF