This study was conducted to establish the microbiological quality standards applying the HACCP system on sushi items of Japanese restaurant in Korea. The study evaluated hygienic conditions of kitchen and workers, pH time-temperature relationship, and microbial assessments during whole process of sushi making in 2001. Overall hygienic conditions were normal for both kitchen and for workers by 3 point scale, but hygienic controls against the cross-contamination were still needed. Each process of sushi making was performed under the risk of microbial contamination, since pH value of most of ingredients was over pH 4.6 and also production time(3.5~6 hrs) were long enough to cause problems. Microorganisms were high enough to cause foodborne illness ranged 8.0$\times$10$^2$~3.3$\times$10$^{6}$ CFU/g of TPC and 1.0$\times$10$^1$~1.6$\times$10$^3$CFU/g of coliforms, although TPC, coliforms and Staphylcoccus aureus were within the standard limits (TPC 10$^2$~10$^{6}$ CFU/g, coliforms 10$^3$CFU/g). However, Salmonella and Vibrio parahaemolyticus were not detected. High populations TPC and coliforms were also found in the cooks' hands and cooking utensils(TPC 10$^2$~10$^{6}$ CFU/100cm$^2$and Coliforms 10$^1$~10$^3$CFU/100cm$^2$). Based on the CCP decision tree analysis, the CCPs were the holding steps far six sushi production line except the tuna and the thawing step for tuna sushi. In conclusion, overall state of sushi production was fairly good but much improvement was still needed.
The Cr(VI) concentrations at the shallow aquifer well (MPH-0-1) of the Moonpyung groundwater monitoring station were in the range of 0.5 to 3.1 mg/L exceeding 10 to 62 times the guideline for drinking-water quality, indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other subsidiary monitoring wells except for MPH-1 and 6. Cross-correlation analyses were conducted for rainfall and groundwater level time series, resulting in the mean time of recharge after precipitation events to be 5.6 days. For rainy season, the water level was raised and the Cr(VI) concentration was several times lower than that during dry season at well MPH-0-1 well. Correlation of the Cr(VI) concentration with the groundwater-level showed that the Cr(VI) reduction was closely related with the groundwater-level rise in the well. However, the groundwater level rise during high water season induced the lateral migration of the Cr(VI)-contaminated groundwater at well MPH-4. We enriched and isolated a chromium reducing bacteria, Enterobacter aerogenes, from the Cr(VI)-contaminated groundwater in the wells MPH-0-1 and MPH-1. The bacteria may play an important role for immobilizing Cr(VI) in the Cr(VI)-contaminated groundwater. Therefore, the migration of the contaminant (Cr(VI) must has been restricted because of the natural attenuation by microbial reduction of Cr(VI) in the groundwater. This research suggests that the bioremediation of the Cr(VI)-contaminated groundwater by the indigenous bacteria may be feasible in the Cr(VI) contaminated groundwater.
Kim, Young-Sug;Kim, Yang-Hee;Kim, Young-Su;Kim, Dae-Hwan;Ryu, Kyong-Shin;Yoon, Mi-Hye
Journal of Food Hygiene and Safety
/
v.31
no.4
/
pp.258-263
/
2016
The risks of sanitary indicative bacteria, heavy metals and chlorinated derivatives in 94 cases of sanitary wet towels used in food services (39 from sanitary wet towel treatment business, 55 from food services) were assessed in the present study. Lead was detected in the range of N.D.~0.41 mg/kg (75 cases were not detected), N.D.~0.25 mg/kg of arsenic (93 cases were not detected), N.D.~0.01 mg/kg of cadmium (7 cases were lower than limit of quantitation; 87 cases were not detected), 0.003 mg/kg ~ 0.09 mg/kg of mercury. And chromium (VI) was not detected from all samples. The level of lead was the highest among the tested heavy metals, and the highest concentration of lead was 0.41 mg/kg. However, it was only 2.1% of legal limit (less than 20 mg/kg). The average moisture content of the samples was 61.9% (50.0% ~ 77.0%) and it showed no relevance to the detection of bacterial counts. Escherichia coli was not detected. Bacterial counts were detected 43 cases and among them, 24 cases were exceeded the legal limit. It was verified that the packaging conditions of sanitary wet towel (whether it is packed by a piece or not and sealed or not) are critical factors to cause the germ contamination and cross contamination in the wet towels. The chlorinated derivatives (chlorites and chlorates) were detected in 17 (19.3%) out of 88 cases. The results would be used as preliminary information to establish the programs of "Safety education for manufacturers and public policy of safety".
Park, Hyang-Sook;Choi, Jung-Young;Sim, Su-Hyun;Kim, Jin-Soo;Choi, Boo-Keun;Jang, Hee-Kyung
Journal of dental hygiene science
/
v.8
no.4
/
pp.275-281
/
2008
Background: This research aims to provide basic data for dental hygienists to implement the infection control after understanding the level of their implementation of infection control in case they have been trained of infection control or not. Method: The respondents in this research are the dental hygienists who worked in the Incheon or Gyeonggi areas between June 16 and July 5, 2008 and who attended complementary training conducted by the Seoul Branch of Korean Dental Hygienists Association in April 2008. A total of 191 questionnaires were distributed to them, and the frequency of the collected data was analyzed using SPSS WIN 12.0. Moreover, cross-tabulation analysis (${\chi}^2$) whose significance level was 0.05, was applied to the data in order to verify the statistical significance of the survey method. Result: There was significant difference in their practice to wear gloves and/or a mask, use a disposable apron and the time to change the apron depending upon the respondents' workplace. There was significant difference in the time to change their apron depending upon the respondents' time of service. 91.6% had been trained in the infection control: of them, 70.7% trained at their school. It was found that 68.6% of the respondents who had been trained in the infection control would wash their hands before treating a patient. 50.3% of the respondents who had been trained in the prevention of contamination would wear their gloves as needed for a basic treatment. Conclusion: Considering the above results of this research, it is concluded that it is necessary to provide practicing dental hygienists with many opportunities for systematic and practical training so that they may faithfully follow the guidelines for the prevention of contamination and to encourage hospitals to have a greater store of relevant facilities, equipment and supplies.
Cheon, Jin-Young;Yang, Ji Hye;Kim, Min Jeong;Lee, Su-Mi;Cha, Myeonghwa;Park, Ki-Hwan;Ryu, Kyung
Journal of Food Hygiene and Safety
/
v.27
no.4
/
pp.420-426
/
2012
The purpose of this study was to identify control points through microbiological hazard analysis in the manufacturing processes of starch noodles. Samples were collected from the ingredients, manufacturing processes, equipment and environment. Microbiological hazard assessments were performed using aerobic plate counts (APC), Enterobacteriaceae (EB), E. coli and five pathogens including B. cereus, E. coli O157:H7, L. monocytogenes, Salmonella spp., and S. aureus. The APC levels in raw materials were from 2.12 to 3.83 log CFU/g. The contamination levels after kneading were 4.31 log CFU/g for APCs and 2.88 log CFU/g for EB counts. APCs decreased to 1.63 log CFU/g and EB were not detected after gelatinization, but their levels slightly increased upon cooling, cutting, ripening, freezing, thawing, and separating. The reuse of cooling and coating water would be a critical source of microbial increase after cooling. After drying, APCs and EB counts decreased to 5.05 log CFU/g and 2.74 log CFU/g, respectively, and the levels were maintained to final products. These results suggest that the cooling process is a critical control point for microbiological safety, and the cooling water should be treated and controlled to prevent cross contamination by pre-requisite program.
Kim, Seong-Jo;Kim, Gwang-Hee;Park, Joong-Hyun;Park, Bo-Geum;Park, Myoung-Su;Oh, Deog-Hwan
Journal of Food Hygiene and Safety
/
v.27
no.4
/
pp.432-441
/
2012
In this study, the transfer rate of wild type Listeria mon, ytogenes (LM) was investigated to establish the standard of safety management during pork meat pr, essing for meat to meat and meat to food contact surfaces contamination at 5 and $10^{\circ}C$. The transfer rate of LM from meat to meat during the pr, essing increased from 0.02% after 30 min to 0.42% after 120 min at $5^{\circ}C$, while for conveyor belt and stainless steel, it decreased from 0.015% and 0.013% after 30 min to 0.002% and 0.0003% after 120 min at $5^{\circ}C$, respectively (p < 0.05). When temperature increased to $10^{\circ}C$, the transfer rates of LM from meat to meat, conveyor belt and stainless steel were the highest at 60 min exposure, and all decreased after 120 min. In reverse, the transfer rate from food contact surface to pork meat was significantly higher than that from pork meat to food contact surface (p < 0.01). Also, the transfer rate to conveyor belt was significantly higher than stainless steel (p < 0.05) and it was highest at 30 min exposure time in both 5 and $10^{\circ}C$. This study indicates that the transfer and adherence rates of LM are influenced by the contact time and temperature. Consequently, these results were utilized to develop a predictive model with a high level of confidence which can lead to prevent cross-contamination during pork meat processing.
Soybean farms in Changnyeong were selected for hazard analysis to establish the Good Agricultural Practices (GAP) model of soybean, and physical, chemical(heavy metal) and biological(sanitary indications, foodborne pathogens) hazard analysis for cultivation environment (soil, water) was carried out. First, bow which is able to be mixed in soil and water was confirmed as physical hazard. Levels (Cd:0.01~0.103, Cu:0.001~6.036, As:0.006~3.045, Hg:ND~0.041, Pb:0.003~3.952, $Cr^{+6}$:0.007~0.496, Zn:0.001~66.500, Ni:0.003~18.010) of heavy metals in soil and water were appropriate for GAP criteria. In biological hazard, APC and coliform in soil were detected at the levels of $6.0{\pm}0.3$ and $3.6{\pm}1.6$ log CFU/g, and levels of water were $3.5{\pm}0.7$ and $1.9{\pm}0.7$ log CFU/mL, while E. coli wasn't detected in all sample. However, coliform in water wasn't appropriate for criteria, and E. coli O157 was detected about 22% in some farms, so it needs ways to prevent contamination by human and animals excrements. In conclusion, it needs proper management to prevent cross-contamination of hazards although physical and chemical hazard level were appropriate for GAP criteria while biological hazard wasn't.
Park, Se-Yeon;Lee, Jong-Ho;Choi, Bum-Ho;Han, Young-Ki;Lee, Kee-Soo
Proceedings of the Korean Vacuum Society Conference
/
2012.08a
/
pp.314-315
/
2012
최근들어 반도체 및 디스플레이 소자의 구조가 복잡해짐에 따라 다층 박막 증착에 대한 중요성이 날로 증가하고 있다. 본 연구에서는 다층 박막을 효율적으로 증착하기 위해 회전이 가능한 육각건을 개발하였고, 이를 이용하여 에너지 절약형 단열 유리 증착 공정을 구현 하였다. 개발된 회전형 육각건은 기존 플래너형 스퍼터링 건의 확장형으로서 최대 6개의 물질을 하나의 챔버에서 증착이 가능하도록 구성되었다. 기존 공정의 경우 서로 다른 물질 증착을 위해서는 각각의 챔버가 필요한 반면, 회전형 육각건을 이용할 경우 하나의 챔버에서 공정을 진행할 수 있어 원가 절감이 가능하다. Fig. 1은 개발된 회전형 육각건의 모식도로서, 스퍼터링 타겟이 장착 가능한 건과, 회전부로 구성되어 있다. 이를 이용하여 투명전극-금속-투명전극-금속-절연체로 구성되어 있는 에너지 절약형 단열 유리용 다층 박막 증착 공정을 개발하였다. 이때 알루미늄이 도핑된 ZnO (AZO)는 RF 마그네트론 스퍼터로, 금속 박막은 DC 스퍼터, $SiO_2$ 및 SiN과 같은 절연 박막은 $O_2$와 $N_2$ 분위기에서 반응성 RF 스퍼터로 각각 증착하였다. Base pressure는 $10^{-7}$ torr였으며, 증착 시 공정 압력은 1~3 mTorr로 조정하였다. 증착 균일도 향상을 위해 20 rpm의 속도로 기판을 회전시켰다. Fig. 2(a)는 ZnO-Ag-ZnO 구조로 이루어진 다층 박막의 단면을 관찰한 투과전자 현미경 사진으로 각 층간의 계면이 뚜렷하게 나타남을 확인할 수 있으며, 각 층간의 intermixing 현상이 발생하지 않음을 확인 가능하다. 이를 보완하기 위해 Fig. 2(b)에서 보는 바와 같이 XPS를 이용하여 depth profile을 측정하였다. 각 층에서 서로 다른 물질이 발견되는 현상, 즉 교차 오염이 발생함에 따라 나타나는 intermixing 없이 거의 순수한 형태의 ZnO, Ag 박막 성분이 검출되었다. 이는 6개의 서로 다른 물질이 장착된 회전형 육각건을 이용하여 고 품질의 다층 박막 증착이 가능함을 제시하는 결과이다. 증착된 다층 박막의 균일도는 3.8%, 가시광선 영역에서 80% 이상의 투과도, 면저항 값은 3 ${\Omega}/{\Box}$ 이하를 보임으로서 에너지 절약형 단열 유리로서의 사양을 만족시키는 결과를 제시하였다.
The objective of this study was to assess the level of contamination of dental equipment surfaces by Staphylococcus aureus and to obtain basic information for the prevention against cross infection between students and outpatients. Human samples were collected by rubbing the oral cavity, anterior noses, and lip of students and outpatients with sterile cotton swabs. Environmental samples were collected from 11 sites at practical laboratory, 4 sites at seminar room, and 5 sites at sterilizing room before, during, and after clinical procedures. These samples were cultured on brain-heart infusion agar at $37^{\circ}C$ for 24 hours. Gram-stained and identified as S. aureus colonies were counted each period and these results were analyzed by t-test and ANOVA test. In human, oral cavity showed the greatest S. aureus counts and there were no statistically significant differences between students and outpatient. Practical laboratory revealed the greatest S. aureus among all environmental groups. The greatest number of S. aureus was observed during clinical procedures (P < 0.05) and light handles, chair head, and spittoon showed a high level of statistically significant differences. In conclusion, S. aureus was dispersed in human and dental clinical environment and increased their number during clinical procedures.
Park, Yeong-Ju;Gwak, Dong-Gyeong;Gang, Yeong-Jae;Jeong, Hong-Gwan
Journal of the Korean Dietetic Association
/
v.9
no.3
/
pp.219-232
/
2003
The purposes of this study were to assess the child care centers' foodservice facility, and to develop the kitchen facility model based on the general sanitation standards and guidelines in order to provide basic information for a plan review to build or renovate child care centers' foodservice facility. The scopes of the study include : 1) field assessment of the foodservice management practices and facilities in 8 public child care centers, and 2 private child care centers which they are subsidized from the government as public child care centers, 2) development of child care centers' kitchen facility model based on the General Sanitation Standards and Guidelines. The results of this study can be summarized as follows : 1. Field Assessment of the Child Care Centers' Foodservice Facility Average number of children in child care centers was 78.0$\pm$24.20, the average space of kitchen was 15.13$\pm$4.25($m^2$). Especially, the average space of kitchen was 18.49$\pm$4.35($m^2$) with enrollment capacity of 90~120 children in child care centers. The inventory level of most foods was relatively low except rice and kimchi. Kitchen facilities and equipments were similar to those of home kitchen and did not meet the standards of institutional practice. Therefore, the director in child care centers should recognize the importance of the sanitation management and pay more attention to the renovation of foodservice facilities as well as sanitation management practices. 2. Development of the Kitchen Facility Model based on the General Sanitation Standards and Guidelines The kitchen facility plan model with enrollment capacity of 100 children was developed based on the results of field assessment and literature review. Suggested kitchen space was 34.16$m^2$(6,100mm×5,600mm). This space was bigger than the results of field survey or precedent study, considered appropriate to implement the general sanitation standards. The main feature of the developed kitchen facility plan and model was product flow in one direction from the arrival of the raw material to the finished product in order to prevent cross contamination and to improve working efficiency.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.