• 제목/요약/키워드: Critical Number

검색결과 2,483건 처리시간 0.026초

Prediction of Critical Reynolds Number in Stability Curve of Liquid Jet ( I )

  • No, S.Y.;Ryu, K.Y.;Rhim, J.H.;Lim, S.B.
    • 한국분무공학회지
    • /
    • 제4권1호
    • /
    • pp.55-61
    • /
    • 1999
  • The first maximum point in the stability curve of liquid jet, i.e., the critical point is associated with the critical Reynolds number. This critical Reynolds number should be predicted by simple means. In this work, the critical Reynolds number in the stability curve of liquid jet are predicted using the empirical correlations and the experimental data reported in the literatures. The critical Reynolds number was found to be a function of the Ohnesorge number, nozzle lengh-to-diameter ratio, ambient Weber number and nozzle inlet type. An empirical correlation for the critical Reynolds number as a function of the Ohnesorge number and nozzle length-to-diameter ratio is newly proposed here. Although an empirical correlation proposed in this work may not be universal because of excluding the effects of ambient pressure and nozzle inlet type, it has reasonably agrees with the measured critical Reynolds number.

  • PDF

직관덕트내에서 정상유동, 진동유동과 맥동유동의 임계레이놀즈수에 관한 연구 (A study on the critical reynolds number of steady, oscillatory and pulsating flow in a straight duct)

  • 박길문;봉태근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권1호
    • /
    • pp.16-20
    • /
    • 1998
  • The critical reynolds number in a square-sectional straight duct is investigated experimentally. The experimental study for the air flow in a square-sectional straight duct is carried out to calssify critical Reynolds number on steady flow and unsteady flow. To calssify the critical Reynolds number we obtained velocity waveform by using a hot-wireanemometer and data acquisition system with photocorder.

  • PDF

Prediction of Critical Reynolds Number in Stability Curve of Liquid Jet (II)

  • Lim, S.B.;So, J.D.;No, S.Y.
    • 한국분무공학회지
    • /
    • 제4권2호
    • /
    • pp.47-52
    • /
    • 1999
  • The prediction of the critical Reynolds number in the stability curie of liquid jet was mainly analyzed by the empirical correlations and the experimental data through the literature. The factors affecting the critical Reynolds number include Ohnesorge number, nozzle length-diameter ratio, ambient pressure and nozzle inlet type. The nozzle inlet type was divided into two groups according to the dependence of the critical Reynolds number on the length-to-diameter ratio of nozzle. The empirical correlations for the critical Reynolds number as a function of above factors mentioned are newly proposed.

  • PDF

BINDING NUMBER CONDITIONS FOR (a, b, k)-CRITICAL GRAPHS

  • Zhou, Sizhong
    • 대한수학회보
    • /
    • 제45권1호
    • /
    • pp.53-57
    • /
    • 2008
  • Let G be a graph, and let a, b, k be integers with $0{\leq}a{\leq}b,k\geq0$. Then graph G is called an (a, b, k)-critical graph if after deleting any k vertices of G the remaining graph of G has an [a, b]-factor. In this paper, the relationship between binding number bind(G) and (a, b, k)-critical graph is discussed, and a binding number condition for a graph to be (a, b, k)-critical is given.

중환자 전문간호사 수요추계연구 (A Study on the Projection of Critical Care Advanced Practical Nurses(APNs))

  • 신성례;손은진
    • 성인간호학회지
    • /
    • 제15권2호
    • /
    • pp.287-295
    • /
    • 2003
  • Purpose: This descriptive study was conducted to project the number of critical care APNs needed in critical care units in an acute care hospital setting, up to the year 2020. Method: Necessary data and information were collected from various funded reports, professional literature, web-sites and personal visits to national and private institutions. The demand of critical care APNs were projected based on two critical care APNs per critical care units. Result: The projected number of critical APNs for the critical care units in acute care hospital settings as follows: 1) The total projected number of critical care APNs needed for critical care units were 1,270 in 2001. 2) By the year 2020, total number of projected critical care APNs needed in critical care units will be 1,080-1,700. Conclusion: In order to match the supply to the need, the professional organization should direct their efforts toward enacting legislation. Educational systems should identify strategies in initiation of critical care APN programs in masters level as well as standardizing curriculums across the programs.

  • PDF

FFR에서의 임계-쌍 경로를 이용한 효율적인 테스트 생성 (Efficient Test Generation using Critical-Pair Path in FFR)

  • 서성환;안광선
    • 전자공학회논문지C
    • /
    • 제36C권4호
    • /
    • pp.1-16
    • /
    • 1999
  • 본 논문에서는 테스트 생성 과정에서 자주 사용되는 임계의 확장 개념으로 임계-쌍을 정의한다. 그리고 임계의 특성을 나타내는 요소로서 임계성, 임계율, 임계설정율 등을 정의한다. 이 요소들을 이용하여 임계-쌍의 사용이 단일 임계의 사용보다 더 효율적이라는 것을 입증하고, FFR에서의 테스트 패턴 생성 시에 임계값에 대한 평가 회수, 경로선의 탐색 회수 및 생성 시간에서 더 효율적이라는 것을 보여준다. 시뮬레이션을 통해서 ISCAS85 벤치마크 테스트 회로에 대한 실험 결과를 비교 분석한다.

  • PDF

HACCP 모델 적용시 호텔 .레스토랑의 세트 메뉴 중 스테이크에 관한 연구 (Studies on the HACCP Model of Steak-Set Menu in Hotel)

  • 양신철
    • 한국관광식음료학회지:관광식음료경영연구
    • /
    • 제12권1호
    • /
    • pp.5-24
    • /
    • 2001
  • This study was focused on the sanitary analysis of hazard factors and the establishment of critical control points on steak-set menu In hotel by the documents and microbiological investigation. The hazard factors of shrimp cocktail were microbial contamination, residual pesticides, unsuitable healing and cross contamination. The hazard factors of potato soap were residual pesticides, microorganisms contamination, unsuitable heating and solanine in potato. The hazard factors of simple salad were microorganisms contamination, unsuitable heating and cross contamination by inappropriate package. The hazard factors of steal were residual antimicrobial drugs, microorganisms contamination, unsuitable heating and cross contamination. The critical control points of shrimp cocktail were temperature control , number of washing and center temperature control of heating step. The critical control points of potato soup were stock temperature control , number of washing and center temperature control of Heating step. The critical control points of simple salad were number of washing and dryness of utensil. The critical control points of steak were stock temperature control , number of washing, center temperature and time control of heating step.

  • PDF

SnPb와 무연 플립칩 솔더의 유효전하수와 임계전류밀도 (Effective Charge Number and Critical Current Density in Eutetic SnPb and Pb Free Flip Chip Solder Bumps)

  • 채광표
    • Journal of Welding and Joining
    • /
    • 제23권5호
    • /
    • pp.49-54
    • /
    • 2005
  • The effective charge number and the critical current density of electromigration in eutetic SnPb and Pb Free $(SnAg_{3.8}Cu_{0.7)$ flip chip solder bumps are studied. The effective charge number of electromigration in eutectic SnPb solder is obtained as 34 and the critical current density is $j=0.169{\times}({\delta}_{\sigma}/{\delta}_x})\;A/cm^2,\;where\;({\delta}_{\sigma}/{\delta}_x})$ is the electromigration-induced compressive stress gradient along the length of the line. While the effect of electromigration in Pb free solder is much smaller than that in eutectic SnPb, the product of diffusivity and effective charge number $DZ^{\ast}$ has been assumed as $6.62{\times}10^{-11}$. The critical length for electromigration are also discussed.

Spatial flow structure around a smooth circular cylinder in the critical Reynolds number regime under cross-flow condition

  • Raeesi, Arash;Cheng, Shaohong;Ting, David S.K.
    • Wind and Structures
    • /
    • 제11권3호
    • /
    • pp.221-240
    • /
    • 2008
  • The spanwise flow structure around a rigid smooth circular cylinder model in cross-flow has been investigated based on the experimental data obtained from a series of wind tunnel tests. Surface pressures were collected at five spanwise locations along the cylinder over a Reynolds number range of $1.14{\times}15^5$ to $5.85{\times}10^5$, which covered sub-critical, single-bubble and two-bubble regimes in the critical range. Separation angles were deduced from curve fitted to the surface pressure data. In addition, spanwise correlations and power spectra analyses were employed to study the spatial structure of flow. Results at different spanwise locations show that the transition into single-bubble and two-bubble regimes could occur at marginally different Reynolds numbers which expresses the presence of overlap regions in between the single-bubble regime and its former and later regimes. This indicates the existence of three-dimensional flow around the circular cylinder in cross-flow, which is also supported by the observed cell-like surface pressure patterns. Relatively strong spanwise correlation of the flow characteristics is observed before each transition within the critical regime, or formation of first and second separation-bubbles. It is also noted that these organized flow structures might lead to greater overall aerodynamic forces on a circular cylinder in cross-flow within the critical Reynolds number regime.

BINDING NUMBERS AND FRACTIONAL (g, f, n)-CRITICAL GRAPHS

  • ZHOU, SIZHONG;SUN, ZHIREN
    • Journal of applied mathematics & informatics
    • /
    • 제34권5_6호
    • /
    • pp.435-441
    • /
    • 2016
  • Let G be a graph, and let g, f be two nonnegative integer-valued functions defined on V (G) with g(x) ≤ f(x) for each x ∈ V (G). A graph G is called a fractional (g, f, n)-critical graph if after deleting any n vertices of G the remaining graph of G admits a fractional (g, f)-factor. In this paper, we obtain a binding number condition for a graph to be a fractional (g, f, n)-critical graph, which is an extension of Zhou and Shen's previous result (S. Zhou, Q. Shen, On fractional (f, n)-critical graphs, Inform. Process. Lett. 109(2009)811-815). Furthermore, it is shown that the lower bound on the binding number condition is sharp.