• Title/Summary/Keyword: Control Parameter

Search Result 4,554, Processing Time 0.028 seconds

Fall Recognition Algorithm Using Gravity-Weighted 3-Axis Accelerometer Data (3축 가속도 센서 데이터에 중력 방향 가중치를 사용한 낙상 인식 알고리듬)

  • Kim, Nam Ho;Yu, Yun Seop
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.254-259
    • /
    • 2013
  • A newly developed fall recognition algorithm using gravity weighted 3-axis accelerometer data as the input of HMM (Hidden Markov Model) is introduced. Five types of fall feature parameters including the sum vector magnitude(SVM) and a newly-defined gravity-weighted sum vector magnitude(GSVM) are applied to a HMM to evaluate the accuracy of fall recognition. A GSVM parameter shows the best accuracy of falls which is 100% of sensitivity and 97.96% of specificity, and comparing with SVM, the results archive more improved recognition rate, 5.2% of sensitivity and 4.5% of specificity. GSVM shows higher recognition rate than SVM due to expressing falls characteristics well, whereas SVM expresses the only momentum.

Double Side SMT and Molding Process Development for mPossum Package

  • Kim, ByongJin;Cho, EunNaRa;Kim, ChoongHoe;Lee, YoungWoo;Lee, JaeUng;Ryu, DongSu;Jung, GyuIck;Kang, DaeByoung;Khim, JinYoung;Yoon, JuHoon;Kim, Sun-Joong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.43-48
    • /
    • 2016
  • 3-Dimensional System in Package (3-D SiP) structure (Amkor calls it mPossum-molded Possum) using double side Surface Mount Technology (SMT) and double side molding was evaluated in order to achieve small/thin form factor as well as good functionality by integration and double side layout. As the new platform on laminate substrate basis, molding process was challenge in mold flow balance at top and bottom side and package warpage control over the overall assembly process. There were two types of different molding process evaluated with 1) 1-step molding which was done at both side at the same time and 2) 2-step molding which was done at the conventional molding process twice. Mold simulation helped to narrow down the material selections and parameters available before actual sample build. There were many challenges for this first trial in design/ parameter and material types but optimized them to enable this structure.

Development of reliable $H_\infty$ controller design algorithm for singular systems with failures (고장 특이시스템의 신뢰 $H_\infty$ 제어기 설계 알고리듬 개발)

  • 김종해
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.4
    • /
    • pp.29-37
    • /
    • 2004
  • This paper provides a reliable H$_{\infty}$ state feedback controller design method for delayed singular systems with actuator failures occurred within the prescribed subset. The sufficient condition for the existence of a reliable H$_{\infty}$ controller and the controller design method are presented by linear matrix inequality(LMI), singular value decomposition, Schur complements, and changes of variables. The proposed controller guarantees not only asymptotic stability but also H$_{\infty}$ norm bound in spite of existence of actuator failures. Since the obtained sufficient condition can be expressed as an LMI fen all variables can be calculated simultaneously. Moreover, the controller design method can be extended to the problem of robust reliable H$_{\infty}$ controller design method for singular systems with parameter uncertainties, time-varying delay, and actuator failures. A numerical example is given to illustrate the validity of the result.

Development of a Wall-climbing Welding Robot for Draft Mark on the Curved Surface (선수미 흘수마크 용접을 위한 벽면이동로봇 개발)

  • Lee, Jae-Chang;Kim, Ho-Gu;Kim, Se-Hwan;Ryu, Sin-Wook
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.112-121
    • /
    • 2006
  • The vertical displacement of a ship on the basis of the sea level is an important parameter for its stability and control. To indicate the displacement on operating conditions, "draft marks" are carved on the hull of the ship in various ways. One of the methods is welding. The position, shape and size of the marks are specified on the shipbuilding rules by classification societies to be checked by shipbuilders. In most cases, high-skilled workers do the welding along the drawing for the marks and welding bead becomes the marks. But the inaccuracies due to human errors and high labor cost increase the needs for automating the work process of the draft marks. In the preceding work, an indoor robot was developed for automatic marking system on flat surfaces and the work proved that the robot welding was more effective and accurate than manual welding. However, many parts of the hull structure constructed at the outdoor are cowed shapes, which is beyond the capability of the robot developed for the indoor works on the flat surface. The marking on the curved steel surface requiring the 25m elevations is one of the main challenges to the conventional robots. In the present paper, the robot capable of climbing vertical curved steel surfaces and performing the welding at the marked position by effectively solving the problems mentioned earlier is presented.

  • PDF

Real time remote management for home network system using bio-physical sensor (생체 센서 시스템을 이용한 실시간 원격 홈 네트워크 시스템)

  • Kim, Jeong-Lae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.1
    • /
    • pp.117-124
    • /
    • 2011
  • This study was realized the home network system for home care by bio-physical sensor system, to convey for the remote physical signal. The composition condition has four functions of displacement point for a Vision, Somatosensory, Vestibular and CNS that the basic measurement used to a Heart Rate, Temperature, Weight. Physical signal are decided to search a max and min point with adjustment of 0.01 unit in the reference level. There were checked physical condition of body balance to compounded a physical neuroceptor of sensory organ for the measurement such as a Vision, Somatosensory, Vestibular, CNS, BMI. There are to check a health care condition through a combination of physical organ with a posturography of a exercise. The service of home network system can be used to support health care management system through health assistants in health care center and central health care system. It was expected to monitor a physical parameter for the remote control health management system.

Perceptual Evaluation of Noise Sources in a Chamber for Residential and Working Environment (주거 및 사무환경 챔버에서의 생활소음에 대한 감성적 평가)

  • Jeon, Jin-Yong;Kim, Kyong-Ho;Jung, Jeong-Ho;Ryu, Jong-Kwan;Cho, Moon-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.437-444
    • /
    • 2002
  • This paper is to provide the basic way of a acoustical evaluation and efficient control noise by investigating the limits of perceptual loudness of living environment and by finding out any correlation between Physical characteristics of noise and psychoacoustic parameters. The limits of perceptual loudness were selected by the subjects in a chamber for residential and working environment. And the noise sources were analyzed to find out whether there is any correlation with Zwicker parameters and ACF factors. In this study especially, to set up the domestic evaluation grade about floor impact noise. we'd like to suggest the loudness Perception research result as fundamental resource for setting up the evaluation grade through the result that is based on annoyance. In the result of this research, upper limit of heavy-weight impact noise was L-60, and lower limit of it was L-50. On the other hand, upper limit of light-weight impact noise was L-70, and lower limit of it was L-55. It seemed that the loudness of noise from vacuum cleaner noise does not affect its perceived noisiness. Noises implicated In human such as floor walking noise and talking sound, are the most irritating noise in office environment.

Uterotrophic Activity of Ethinyl Estradiol by Gavage and Subcutaneous Administration in Immature Female Rats (미성숙 랫드에 있어서 경구 및 피하투여에 의한 Ethinyl estradiol의 자궁증식효과)

  • 정문구;임광현;김종춘;김영희;서정은;하창수
    • Toxicological Research
    • /
    • v.16 no.3
    • /
    • pp.201-209
    • /
    • 2000
  • In association with the international validation program to establish a rodent uterotrophic assay, we conducted preliminary uterotrophic assay proposed by GECD using immature female rats. In the present study, oral and subcutaneous routes were chosen to compare the effects of estrogenic com-pounds in the two dosing regimens. The reference compound ethinyl estradiol (EE) and the antagonist ZM189154(ZM) were administered by gavage or subcutaneously (s.c.) to immature female SD rats from 20 to 22 days of age. For each study, sixty-six female rats were randomly assigned to eleven groups: Untreated control, EE 0,0.01, 0.03, 0.1, 0.3, 1.0,3.0 and 10.0 $\mu\textrm{g}$/kg, EE 3.0 $\mu\textrm{g}$/kg(gavage)/0.3 $\mu\textrm{g}$/kg(s.c) & ZM 0.1 mg/kg, and EE 3.0 $\mu\textrm{g}$/kg(gavage)/0.3 $\mu\textrm{g}$/kg (s.c) & ZM 1.0 mg/kg. There were no treatment-related changes in clinical signs, body weights, food consumption, and necropsy findings in any groups of two studies. The wet and blotted uterus weights increased dose-dependently. Histopathological examination revealed that diameter of uterine duct, height of uterine luminal epithelium. and height oj vaginal epithelium increased dose-dependently. The proliferating cell nuclear antigen (PCNA) immunoreactive cells were increased in number dose-dependently. The estrogenic effects observed in the present studies occurred at $\geq$ 0.3 $\mu\textrm{g}$/kg of oral dose and $\geq$ 0.1 $\mu\textrm{g}$/kg of s.c. dose. An antagonistic effect of ZM against EE was found in both uterus weight and histopathological parameters. From the results obtained, it can be concluded that dose-dependence of the uterotrophic assay using EE and ZM was well demonstrated by gavage and subcutaneous administration and that the estrogenic effects of EE by s.c. dose were higher than those by gavage administration. In addition, blotted uterus weight was more sensitive than wet uterus weight and vaginal epithelial height was found to be the most sensitive parameter among the parameters examined.

  • PDF

Design of Maximum Green Time Parameters for Traffic Actuated Operation (감응식 신호운영을 위한 최대녹색시간의 설계)

  • KIM, Jin Tae
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.4
    • /
    • pp.123-134
    • /
    • 2002
  • 감응식 신호운영변수 설계에 관한 연구는 정주기식 신호운영변수 설계의 그것보다 그 수준이 현저히 미비하며 이는 감응식 신호운영 특성을 반영한 평가방법의 부재로 감응식 운영변수의 평가가 불가능하였기 때문이다. 본 논문은 최근에 소개된 평균 감응현시 녹색시간 추정 수리모형을 이용하여 Highway Capacity Manual (HCM) 지체도를 최소화하는 최대녹색시간의 설계방안을 제시한다. - '최소녹색시간'과 '단위연장시간'은 보행자 횡단시간 및 차량 차두시간 등 지역별 운전자/보행자의 특성과 관련이 있어 일반적인 최적화 설계 수리모형의 적용에 무리가 있어 제외한다. 제안된 설계방안은 감응식 운영논리를 토대로 감응현시 군의 평균녹색시간과 평균주기를 산정하며, HCM 지체도를 평가하고, 가능한 대안 중 지체를 최소화하는 최대녹색시간 운영변수 군을 '혼혈 유전자 알고리즘'으로 도출한다. 현장실험을 통해 도출이 불가능한 실제 최적치를 Corridor Simulation(CORSIM)모형을 이용하여 추정하였고 이를 제안된 설계방안으로 도출된 최대녹색시간 운영변수' 값들과 비교하였다. 비교결과 교차로 v/c 비율이 1.0 보다 낮을 시는 제안된 방법을 통해 설계된 최대녹색시간 운영변수 군이 최소 CORSIM 지체도를 산출하는 최대녹색시간 운영변수 군과 동일한 것으로, v/c비율이 1.0보다 높을 시는 다른 것으로 결과되었다. v/c비율이 1.0 보다 높은 경우는 정주기식 교차로 운영에 효율적이라 감응식 운영의 필요를 벗어나므로 제안된 최대녹색시간 설계방안은 감응식 신호운영 필요범위 내에서 효율적이다. 기존의 최대녹색시간 설계는 정수기식 최적녹색시간을 기준으로 최대녹색시간을 추정하며, 그러한 과정을 돕기 위하여 추정범위(설계자가 범위 내에서 임의로 선택함)를 제시하는 것이 기존의 연구임을 비교하면 본 연구에서 제안하고 있는 설계방법의 의미가 크다.

Blood glucose change after surgical administration of insulin formula into rat intestinal regions (Rat의 intestine 각 부위에 수술적으로 투여 된 insulin 제제에 의한 혈당 변화)

  • Kim, Nam Joong;Kim, Myung-Cheol
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.2
    • /
    • pp.283-288
    • /
    • 2002
  • The present study was carried out to examine the effect of insulin formula on blood glucose change in normal Sprague-Dawley male rats. Also, this study was performed to investigate the feasibility of oral insulin formula development. To administrate the insulin formula into intestine, the surgical technique, celiotomy, was performed in rats. Insulin formula was administrated at a dose of 24.5 IU/kg via duodenum, ileum, and colon of the rats, and the blood glucose level was measured. For the comparison, the vehicle without insulin was administrated into ileum via celiotomy. Also, this insulin formula was administrated into rats orally using sonde and the same parameter was treasured. The bloods of all groups were collected from tail veins using syringes at given time interval. Orally administrated group did not show the change of blood glucose level and control group slightly show the change of blood glucose level at 1 hour after celiotomy. All intestinally administrated groups showed the change of blood glucose level. Among the tested groups, ileac administration group and colonic administration group showed the significant change of blood glucose level. Particularly, ileac administration group showed the lowest blood glucose level. To calculate the bioavailability of intestinal and oral administration, insulin solution was injected subcutaneosly, common insulin injection route, into another normal rats. The bioavailability of ileac group was 8.3% when compared with subcutaneous injection, duodenal group was 1.8%, colonic group was 4.2%, and oral group was 0.2%, respectively.

Design of Time-varying Sliding Surface for Higher-order Uncertain Systems (고차 불확실 시스템을 위한 시변 슬라이딩 평면의 설계)

  • Kim, Ga-Gue;Choi, Bong-Yeol
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.6
    • /
    • pp.37-44
    • /
    • 1999
  • In this paper, we present a new sliding surface with a time-varying repeated root for fast and robust tracking of higher-order uncertain systems. The repeated root is moved to target one with stabilizing the closed-loop time-varying system in sliding mode. This initial root is obtained so that shifting distance of the surface may be minimized with respect to an initial error, and the intercept is produced so that the surface may pass the initial error. Under the allowable input, fast shifting of the surface and movement of the repeated root enable the error convergence rate to be increased. The proposed sliding mode control makes the error always remain on the surface from the beginning, and therefore, the system is more insensitive to parameter uncertainties and external disturbances. In simulation, the effectiveness of the proposed method is proved by comparison with the conventional one.

  • PDF