Browse > Article
http://dx.doi.org/10.9708/jksci.2011.16.1.117

Real time remote management for home network system using bio-physical sensor  

Kim, Jeong-Lae (Dept. of Biomedical Engineering, Eulji University)
Abstract
This study was realized the home network system for home care by bio-physical sensor system, to convey for the remote physical signal. The composition condition has four functions of displacement point for a Vision, Somatosensory, Vestibular and CNS that the basic measurement used to a Heart Rate, Temperature, Weight. Physical signal are decided to search a max and min point with adjustment of 0.01 unit in the reference level. There were checked physical condition of body balance to compounded a physical neuroceptor of sensory organ for the measurement such as a Vision, Somatosensory, Vestibular, CNS, BMI. There are to check a health care condition through a combination of physical organ with a posturography of a exercise. The service of home network system can be used to support health care management system through health assistants in health care center and central health care system. It was expected to monitor a physical parameter for the remote control health management system.
Keywords
bio-physical sensor system; Postural sway stability; Home network system; WDI;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Pare G, Jaana M, Sicotte C, "Systematic review of home telemonitoring for chronic diseases: the evidence base," J Am Med Inf Assoc, Vol.14(3), pp.269-77, 2007.   DOI   ScienceOn
2 Roback K, Herzog A,"Home informatics in healthcare: assessment guidelines to keep up quality of care and avoid adverse effects," Technol Health Care, Vol.11(3), pp.195-206, 2003.
3 Lai C.C., Lee R.G., Hsiao C.C., Liu H.S., Chen C.C., "A H-QoS-demand personalized home physiological monitoring system over a wireless multi-hop relay network for mobile home healthcare applications," J of Network and Computer Applications, Vol.32, pp.1229-1241, 2009.   DOI   ScienceOn
4 Shumway-Cook A and Horack FB. "Assessing the influence of sensory interaction on balance: Suggestion from field," Phys Ther. Vol66, pp.1548-1550,1986.   DOI
5 Fei DY, Zhao X, Boana C, Hughes E, Bai, Merrell R, Rafiq A, A biomedical sensor system for real time of astronauts' phisiological parameters during extra-vehicular activities," Computer in Biology and Medicine, Vol40, pp.635-642, 2010.   DOI   ScienceOn
6 Stallings W, "Wireless comunications & networks, 2nd ed," New Jersey: Prentice-Hall; 2004.
7 Varshney U, "Patient monitoring using infrastructure-oriented wireless LANs," Int J Electron Healthcare, Vol.2(2), pp.149-63, 2006.   DOI
8 Cohn H, Blatchly CA, Gombash LL. "A study of the clinical test of sensory interaction and balance," Phys Ther , Vol73, pp.346-35,1993.   DOI
9 Shulmann DL, Goldfish E and Fisher AG. "Effect of movement on dynamic equilibrium," Phys Ther. Vol67, pp.1054-1057,1987.   DOI
10 Lorincz K, Malan DJ, Fulford-Jones TRF, Nawoj A, Clavel A, Shnayder V, et al., "Sensor networks for emergency response: challenges and opportunities," IEEE Pervasive Comput, Vol.3(4), pp.16-23, 2004.   DOI   ScienceOn
11 Lorincz K, Malan DJ, Fulford-Jones TRF, Nawoj A, Clavel A, Shnayder V, et al., "Sensor networks for emergency response: challenges and opportunites," IEEE Pervasive Comput, Vol.3(4), pp.16-23, 2004.   DOI   ScienceOn
12 Milenkovic A, Otto C, Jovanov E, "Wireless sensor networks for personal health monitoring: issues and an implementation," Comput Commun, Vol.29(13-14), pp.2531-33, 2006.
13 Lorincz K, Malan DJ, Fulford-Jones TRF, Nawoj A, Clavel A, Shnayder V, et al., "Sensor networks for emergency response: challenges and opportunities," IEEE Pervasive Comput, Vol.3(4), pp.16-23, 2004.   DOI   ScienceOn
14 Varshney U,"Pervasive healthcare and wireless health monitoring," Mobile Network Appl, Vol.12(2-3), pp.113-27, 2007.   DOI   ScienceOn
15 Ruggiero C, Sacile R., Giacomini M., "Home telecare," J Telemed Telecare, Vol.5(1), pp.11-7, 1999.   DOI   ScienceOn
16 Varshney U, Sneha S, "Patient monitoring using ad hoc wireless networks: reliability and power management," IEEE Commun Mag, Vol.44(4), pp.49-55, 2006.   DOI   ScienceOn
17 Lee R-G, Chen K-C, Hsiao C-C, Tseng C-L, "A mobile care system with alert mechanism," IEEE Trans Inform Technol Biomed, Vol.11(5), pp.507-17, 2007.   DOI   ScienceOn
18 Rigby M.,"Applying emergent ubiquitous technologies in health: the need to respond to new challenges of opportunity, expectation, and responsibility," Int J Med inform, Vol.76(suppl. 3), pp.349-52, 2007.   DOI   ScienceOn
19 Hernadez Al, Mora F, Villegas G, Passriello G, Carrault G, "Rea-time ECG transmission via Internet for nonclinical applications," IEEE Trans Inform Technol Biomed, Vol.5(3), pp.253-7, 2001.   DOI   ScienceOn
20 Lee R-G, Chen H-S, Lin C-C, Chang K-C, Chen J-H, "Home telecare system using cable television plants an experimental field trial." IEEE Trans Inform Technol Biomed, Vol.4(1), pp.37-44, 2000.   DOI   ScienceOn
21 Stefanov DH, Bien Z, Bang WC., "The smart house for older persons and persons with physical disabilities: structure, technology arrangements, and perspectives," IEEE Trans Neural Syst Rehab Eng, Vol.12(2), pp.228-50, 2004.   DOI   ScienceOn
22 Alwan M, Mack DC, Dalal S, Kell S, Turner B, Felder RA, "Impact of passive in-home health status monitoring technology in home health: outcome pilot. In: Proceedings of the 1st distributed diagnosis and home healthcare (D2H2)conference," Arlington , VA, USA, Vol2-4 pp.79-82, April,2006.
23 Naughton C, Bennett K, Feely J,"Prevalence of chronic disease in the elderly based on a national pharmacy claims database," Age Ageing, Vol.35(6), pp.633-6, 2006.   DOI   ScienceOn
24 Massion J., "Postural control system" Curr Opin Neurobiol Vol.4, pp.877-87, 1994.   DOI   ScienceOn
25 Koch S, "Heme telehealth-current state and future trends," Int J Med Inform, Vol.75(8), pp.565-76, 2006.   DOI   ScienceOn
26 Bratan T, Clake M, Jones R, Larkworthy A, Paul R, "Evaluation of the practical feasibility and acceptability of home monitoring in residential homes," J Telemed Telecare, Vol.11(suppl.1), pp.29-31, 2005.   DOI