• Title/Summary/Keyword: Continuous Measurement

Search Result 1,082, Processing Time 0.028 seconds

An Study on the Erosion Characteristics of Tube CN98 (CN98 포신의 마모특성 연구)

  • Kim, Jae-Kab
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.42-52
    • /
    • 2006
  • Tube erosion can be defined as a phenomenon for an increment of bore diameter, a declination of accuracy and utility of tube by firing. This study introduces the characteristics of tube life for the 155 mm K9 SHP Using a tube history book with bore measurement data and firing data of standard charge, this study analyzed the EFC vs Tube life and EFC with heat transfer effect formula as a consideration of continuous firing vs tube life. The results were compared with Firing Table(FT 155-K9-1) after the analysis. Also, this study suggests that CN98 tube can be rifled as 1000 EFC through the severe condition with continuous firing.

The Study about a plan to develop an ITSM building framework applied ITIL Continuous Service Improvement Process (ITIL 프로세스 개선 모델을 적용한 ITSM 구축 모형 개발 방안에 관한 연구)

  • Kwon, Sang-Kook;Kim, Jeong-Jung
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2006.05a
    • /
    • pp.134-141
    • /
    • 2006
  • Today, the role of IT is so important that it is regarded as a partner of business, not a simple supporter. The more important the role of IT becomes, the higher the level of business needs rises and the more customers want. In the market of IT, more and more enterprises are establishing ITSM processes based on the ITIL for these environments: however they are experiencing the processes of trial and errors because of the shortage of references To improve these problems, in this study, we developed the ITSM model defined by investigation of the instance to which we have applied the ITIL Continuous Service Improvement Process which contains five phases such as High level Business Objectives. Assessment. Measurable Targets, Process Improvement, Measurement and Metrics. This model is an ITSM building framework to understand the concepts over the length and breadth of ITIL and minimize the trial and errors appearing during the building of the ITSM processes, and this paper presents a plan to develop the frameworks.

  • PDF

Design of Screening Procedures Using a Surrogate Variable with Specified Producer's and Consumer's Risks (대용특성을 활용한 규준형 스크리닝 절차의 설계)

  • Hong, Sung-Hoon;Jung, Min-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.4
    • /
    • pp.23-30
    • /
    • 2009
  • When the measurement method for a performance variable is destructive or expensive, it is profitable to replace the performance variable with a highly correlated surrogate variable. In this paper we propose screening procedures using a surrogate variable with specified producer's and consumer's risks. Blending the basic concepts of acceptance sampling plans and screening procedures, the proposed model can be used effectively by quality professionals. Two models are considered: the normal model with dichotomous performance and continuous surrogate variables, and the bivariate normal model with continuous performance and surrogate variables. It is assumed the surrogate variable given the performance variable is normally distributed in the normal model, and performance and surrogate variables are jointly normally distributed in the bivariate normal model. For the two models, producer's and consumer's risks are derived, and methods of finding the optimal screening procedures are presented. Numerical examples are also given.

Channel Equalization for High-speed applications using MATLAB

  • Kim, Young-Min;Park, Tae-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.2
    • /
    • pp.57-66
    • /
    • 2019
  • This paper compared the performance with an overview of channel equalization techniques used in high-speed serial transceivers, including the homogeneous architecture and associated components for the GHz interconnect of backplane and cable channels. It also used the MATLAB tool to present system analysis and simulation results for continuous time equivalent structures. In the case of conventional continuous equalization, high frequency deficits occur due to the use of a comparator that is difficult to implement as well as the low speed limit. In this paper, the channel equalization technique based on the power spectrum analysis of clocks was used to compensate for the frequency loss, and the application of the TX+Channel and TX+Equalizer filters enabled the measurement of attenuation and equivalence without comparators. The application of blender and band-pass filters at high speeds also showed significant effectiveness.

Development and Characterization of Ultrasonic transducers for High Temperature Contact Measurement (고온 접촉식 탐상용 초음파 탐촉자 개발 및 평가)

  • Kim, Ki-Bok;Kim, Byoung-Geuk;Lee, Seung-Seok;Yoon, Nam-Won;Yoon, Dong-Jin;Ahn, Yoon-Kook
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.14-20
    • /
    • 2003
  • Piezoelectric ultrasonic transducers for high temperature contact measurement were developed. These high temperature ultrasonic transducers (HTUT) consisted of bismuth titanate piezoceramic element whose Curie temperature is higher than $600^{\circ}C$, a backing material of the mixture of tungsten powder and inorganic binder, an inner alumina tube, a wear Plate and a housing. The operational frequencies or the HTUT were 1.04 and 2.08 MHz, respectively. Various commercially available couplants for high temperature were evaluated and compared. As a couplant for high temperature ultrasonic testing between HTUT and test specimen, gold epoxy was selected. The peak amplitude of pulse-echo signals from steel test specimen decreased with increasing temperature. The operational temperature of the HTUT reached up to $500^{\circ}C$ at which the continuous contact measurement was possible.

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

Continuous Measurement of Ammonium-nitrogen and Nitrate-nitrogen using a Ion-Selective Microelectrode (이온선택성 미소전극을 이용한 암모니아성 질소 및 질산성 질소의 연속 농도 측정)

  • Lim, Mi-Ji;Seon, Ji-Yun;Park, Jeung-Jin;Byun, Im-Gyu;Park, Tae-Joo;Lee, Tae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.6
    • /
    • pp.718-724
    • /
    • 2008
  • The ion selective microelectrode (ISME) has been used for measuring the ion profile of DO, $NH_4{^+}-N$, $NO_2{^-}-N$ and $NO_3{^-}-N$ in biofilm. In this study we evaluated the detection limit and validity of ISME and applied ISME for the continuous measurement of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration in the modified Ludzack-Ettinger (MLE) process. Average detection limits of $NH_4{^+}-N$ and $NO_3{^-}-N$ ISME were $10^{-4.44}M$ and $10^{-4.62}M$, respectively. Since the ISME with $5{\sim}10{\mu}m$ of tip diameter showed a faster response time than that of $1{\sim}5{\mu}m$, the ISME with a tip diameter of $5{\sim}10{\mu}m$ was fabricated and used to make real-time ion detections. Direct monitoring of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentrations in the aerobic (2) tank causes the instability of the electromotive force (EMF) for the initial 5~8 hours and also causes remarkable error values of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration. This phenomenon is caused by aeration and mixing in the reactor. Thus, the measuring chamber was newly designed for the aerobic (2) tank and then the EMF of the ISME were stabilized in less than 1 hour. Errors of $NH_4{^+}-N$ and $NO_3{^-}-N$ concentration were decreased after stabilization of the EMF. The ISME analysis were well corresponded to the results of auto analyzer and ion chromatography. Consequently, the concentration of $NH_4{^+}-N$ and $NO_3{^-}-N$ could be continuously measured for 178 hours by the ISME.

A Method on the Improvement of the Minimum Detection Distance of the Remote Measurement Level Meter (원격 측정 레벨계의 최소 탐지거리 성능 개선 방법)

  • Park, Dongkun;Lee, Kijun
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.535-543
    • /
    • 2018
  • Recently, level meters have been associated with the safety and maintenance of industrial sites and require a wide measurement range. Generally, to ensure the measurement range of the level meter, the measurement environment is improved to reduce the noise or to compensate the distortion of the signal through signal processing. The noise of FMCW (Frequency Modulated Continuous Wave) radar level meter or the distortion of the signal affects the near region characteristics of the level gauge, resulting in a reduction of the minimum detection distance. In this paper, an equalizer filter considering characteristics of window function and bit spectrum is applied to remove the noise in the near region of the level meter to improve the minimum detection distance performance and to improve the measurement reliability in the vicinity of the level meter, which is relatively difficult to detect, we want to improve the detection range.

Density Measurement for Continuous Flow Segment Using Two Point Detectors (두 개의 지점 검지기를 이용한 연속류 구간의 밀도측정 방안)

  • Kim, Min-Sung;Eom, Ki-Jong;Lee, Chung-Won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.1
    • /
    • pp.37-44
    • /
    • 2009
  • Density is the most important congestion indicator among the three fundamental flow variables, flow, speed and density. Measuring density in the field has two different ways, direct and indirect. Taking photos with wide views is one of direct ways, which is not widely used because of its cost and lacking of proper positions. Another direct density measuring method using two spot detectors has been introduced with the concept of instantaneous density, average density and measurement interval. The relationship between accuracy and measurement interval has been investigated using the simulation data produced by Paramics API function. Finally, density measurement algorithm has been suggested including exponential smoothing for device development.

  • PDF

A Study on Establishing Performance Measurement and Evaluation System of ATM (ATM 성능측정 및 평가체계 구축 연구)

  • Seo, Youngsung;Park, Bomi;Kim, Jun-hyuk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.26 no.1
    • /
    • pp.37-43
    • /
    • 2018
  • There has been the migration to a performance-based approach in many areas which include transition planning at global, regional and local levels, performance-based navigation and safety management. Achieving continuous success of Air Traffic Management (ATM) systems would require a performance-based approach to raise productivity and efficiency of it through performance measurements and reviews. This paper considers establishment planning of performance measurement and evaluation system for ATM. Related to key performance areas proposed by International Civil Aviation Organization, performance indicators and metrics which could be used to measure and evaluate ATM performance are presented. Also, organizational system and operational planning for efficient operation of ATM are presented.