• 제목/요약/키워드: Contact Probe

검색결과 266건 처리시간 0.031초

Performance Characteristics of Polymer Photovoltaics using Dimethyl Sulphoxide incorporated PEDOT:PSS Buffer Layer

  • 박성희;이혜현;조영란;황종원;강용수;최영선
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.238-239
    • /
    • 2010
  • Dimethyl sulphoxide (DMSO) is one of the widely-used secondary dopants in order to enhance the conductivity of poly(3, 4-ethylenedioxy-thiophene):poly(styrene sulfonate) (PEDOT:PSS) film. In this work, we investigated the effect of DMSO doping in to PEDOT:PSS on the electrical performance of the bulk heterojunction photovoltaics consisting of poly(3-hexylthiophene-2, 5-diyl) and phenyl-C61-butyric acid methyl ester. Correlation between the power conversion efficiency and the mechanism of improving conductivity, surface morphology, and contact properties was examined. The PEDOT:PSS films, which contain different concentration of DMSO, have been prepared and annealed at different annealing temperatures. The mixture of DMSO and PEDOT:PSS was prepared with a ratio of 1%, 5%, 15%, 25%, 35%, 45%, 55% by volume of DMSO, respectively. The DMSO-contained PEDOT:PSS solutions were stirred for 1hr at $40^{\circ}C$, then spin-coated on the ultra-sonicated glass. The spin-coated films were baked for 10min at $65^{\circ}C$, $85^{\circ}C$, and $120^{\circ}C$ in air. In order to investigate the electrical performance, P3HT:PCBM blended film was deposited with thickness of 150nm on DMSO-doped PEDOT:PSS layer. After depositing 100nm of Al, the device was post-annealed for 30min at $120^{\circ}C$ in vacuum. The fabricated cells, in this study, have been characterized by using several techniques such as UV-Visible spectrum, 4-point probe, J-V characteristics, and atomic force microscopy (AFM). The power conversion efficiency (AM 1.5G conditions) was increased from 0.91% to 2.35% by tuning DMSO doping ratio and annealing temperature. It is believed that the improved power conversion efficiency of the photovoltaics is attributed to the increased conductivity, leading to increasing short-circuit current in DMSO-doped PEDOT:PSS layer.

  • PDF

코발트/니켈 복합실리사이드의 실리사이드온도에 따른 면저항과 미세구조 변화 (Sheet Resistance and Microstructure Evolution of Cobalt/Nickel Silicides with Annealing Temperature)

  • 정영순;정성희;송오성
    • 한국재료학회지
    • /
    • 제14권6호
    • /
    • pp.389-393
    • /
    • 2004
  • The silicide layer used as a diffusion barrier in microelectronics is typically required to be below 50 nm-thick and, the same time, the silicides also need to have low contact resistance without agglomeration at high processing temperatures. We fabricated Si(100)/15 nm-Ni/15 nm-Co samples with a thermal evaporator, and annealed the samples for 40 seconds at temperatures ranging from $700^{\circ}C$ to $1100^{\circ}C$ using rapid thermal annealing. We investigated microstructural and compositional changes during annealing using transmission electron microscopy and auger electron spectroscopy. Sheet resistance of the annealed sample stack was measured with a four point probe. The sheet resistance measurements for our proposed Co/Ni composite silicide was below 8 $\Omega$/sq. even after annealing $1100^{\circ}C$, while conventional nickel-monosilicide showed abrupt phase transformation at $700^{\circ}C$. Microstructure and auger depth profiling showed that the silicides in our sample consisted of intermixed phases of $CoNiSi_{x}$ and NiSi. It was noticed that NiSi grew rapidly at the silicon interface with increasing annealing temperature without transforming into $NiSi_2$. Our results imply that Co/Ni composite silicide should have excellent high temperature stability even in post-silicidation processes.

폴리에틸렌 표면에 글리시딜메타크릴레이트의 플라즈마 유도 그래프트 공중합 (Plasma-induced Graft Copolymerization of Glycidyl Methacrylate on the Surface of Polyethylene)

  • 김지은;류욱연;최호석;김재하;박한오
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.137-144
    • /
    • 2012
  • 대기압 플라즈마 처리 및 글리시딜 메타크릴레이트(glycidyl methacrylate, GMA) 그래프트 공중합을 통해 폴리에틸렌(polyethylene, PE)의 표면을 개질하였다. 우선 RF-power, 플라즈마 처리시간, Ar의 유량, 처리 시편의 이동속도를 변화시켜 PE의 표면을 플라즈마 처리하고, 처리된 각 시편들의 접촉각 측정과 표면자유에너지 계산을 통하여 최적의 플라즈마 표면처리 조건을 구하였다. 그 결과 최적 표면처리 조건은 RF-power 200W, 플라즈마 처리시간 600 sec, Ar 유량 5 LPM, 처리 시편의 이동속도 20 mm/sec 이었다. 이 조건하에서 처리된 PE 표면에 GMA를 최대한 많이 도입하기 위하여 GMA 농도와 반응온도, 반응시간을 변수로 그래프트 공중합을 수행하였다. 반응전후 시편의 질량차이 분석을 통하여 각 시편들의 그래프트도(grafting degree, GD)를 측정하고, 가장 높은 GD를 얻을 수 있는 그래프트 공중합 반응조건을 결정하였다. 그 결과 GMA 최대 도입 조건은 GMA 농도 20 vol%, 반응온도 $80^{\circ}C$, 반응시간 4 hr 이었다.

알루미늄 합금과 아연도금강판의 이종 겹치기 마찰교반접합에서 기계적성질에 미치는 Tool Geometry의 영향 (The Effect of Tool Geometry on the Mechanical Properties in a Friction Stir Welded Lap Joint between an Al Alloy and Zn-coated Steel)

  • 김남규;김병철;정병훈;송상우;;강정윤
    • 대한금속재료학회지
    • /
    • 제48권6호
    • /
    • pp.533-542
    • /
    • 2010
  • The specific motivation for joining an Al alloy and Zn-coated steel arises from the need to save fuel consumption by weight reduction and to enhance the durability of vehicle structures in the automobile industry. In this study, the lap joining A6K31 Al alloy (top) and SGARC340 Zn-coated steel (bottom) sheets with a thickness of 1.0 mm and 0.8 mm, respectively, was carried out using the friction stir weld (FSW) technique. The probe of a tool did not contact the surface of the lower Zn-coated steel sheet. The friction stir welding was carried out at rotation speeds of 1500 rpm and travel speeds of 80~200 mm/min. The effects of tool geometry and welding speed on the mechanical properties and the structure of a joint were investigated. The tensile properties for the joints welded with a larger tool were better than those for the joints done with a smaller tool. A good correlation between the tensile load and area of the welded region were observed. The bond strength using a larger tool (M4 and M3) decreased with an increase in welding speed. Most fractures occurred along the interface between the Zn-coated steel and the Al alloy. However, in certain conditions with a lower welding speed, fractures occurred at the A6K31 Al alloy.

Imprinted Graphene-Starch Nanocomposite Matrix-Anchored EQCM Platform for Highly Selective Sensing of Epinephrine

  • Srivastava, Juhi;Kushwaha, Archana;Singh, Meenakshi
    • Nano
    • /
    • 제13권11호
    • /
    • pp.1850131.1-1850131.19
    • /
    • 2018
  • In this paper, an electrochemical sensor for epinephrine (EP), a neurotransmitter was developed by anchoring molecularly imprinted polymeric matrix (MIP) on the surface of gold-coated quartz crystal electrode of electrochemical quartz crystal microbalance (EQCM) using starch nanoparticles (Starch NP) - reduced graphene oxide (RGO) nanocomposite as polymeric format for the first time. Use of EP in therapeutic treatment requires proper dose and route of administration. Proper follow-up of neurological disorders and timely diagnosis of them has been found to depend on EP level. The MIP sensor was developed by electrodeposition of starch NP-RGO composite on EQCM electrode in presence of template EP. As the imprinted sites are located on the surface, high specific surface area enables good accessibility and high binding affinity to template molecule. Differential pulse voltammetry (DPV) and piezoelectrogravimmetry were used for monitoring binding/release, rebinding of template to imprinted cavities. MIP-coated EQCM electrode were characterized by contact angle measurements, AFM images, piezoelectric responses including viscoelasticity of imprinted films, and other voltammetric measurements including direct (DPV) and indirect (using a redox probe) measurements. Selectivity was assessed by imprinting factor (IF) as high as 3.26 (DPV) and 3.88 (EQCM). Sensor was rigorously checked for selectivity in presence of other structurally close analogues, real matrix (blood plasma), reproducibility, repeatability, etc. Under optimized conditions, the EQCM-MIP sensor showed linear dynamic ranges ($1-10{\mu}M$). The limit of detection 40 ppb (DPV) and 290 ppb (EQCM) was achieved without any cross reactivity and matrix effect indicating high sensitivity and selectivity for EP. Hence, an eco-friendly MIP-sensor with high sensitivity and good selectivity was fabricated which could be applied in "real" matrices in a facile manner.

티타늄 임플란트의 표면처리가 골유착에 미치는 영향에 관한 조직형태계측학적 연구 (A histomorphometric study on the effect of surface treatment on the osseointegration)

  • 최웅재;조인호
    • 대한치과보철학회지
    • /
    • 제47권4호
    • /
    • pp.445-456
    • /
    • 2009
  • 연구목적: 임플란트를 이용한 수복의 임상적인 성공에 중요한 역할을 하는 초기 골유착의 향상을 위해 티타늄의 표면 거칠기 조절과 함께 생체활성도를 가진 표면으로 변화시키는 방법에 관한 연구가 이루어지고 있다. 표면 거칠기의 적절한 증가는 조골세포의 활동을 증가시키고 골과 임플란트의 접촉과 유지를 촉진시킨다고 보고되고 있고 또한 알칼리와 열처리를 통하여 생체 활성 표면을 얻을 수 있는 것으로 보고되고 있다. 이에 본 연구에서는 알칼리 및 열을 이용한 티타늄 표면 처리가 골유착에 어떤 영향을 미치는지 알아보고자 하였다. 연구재료 및 방법: 기계절삭된 임플란트를 대조군으로 하여 (1군), 5 M NaOH 용액에 처리한 임플란트를 대기 중에서 열처리한 군 (2군)과 진공에서 열처리한 군 (3군)으로 분류하였다. 알칼리와 열처리를 시행한 임플란트들의 표면 특성을 관찰하고 가토에 식립하여 치유 기간에 따라서 조직학적 및 조직형태계측학적으로 비교하고 EPMA (Electron Probe Micro Analyzer)를 이용하여 치유 기간 별 골성분의 변화를 분석하였다. 결과 및 결론: 대기 중에서 열처리한 2군이 통계적으로 유의하게 (P<.05) 증가된 표면 거칠기를 보였다. 이렇게 만들어진 임플란트를 가토에 식립하여 조직 형태계측학적 분석을 시행한 결과 골-임플란트 접촉율은 전반적으로 치유기간이 경과하면서 증가하는 것으로 나타났으며 2군과 3군에서 통계적 분석결과 치유기간 간에 유의한 차이가 관찰되었고 (P<.05), 골-임플란트 면적율 (BA) 또한 골 임플란트 접촉율과 비슷한 양상을 보였으며 통계적 분석결과 2군에서만 치유기간별로 통계적으로 유의한 차이가 관찰되었다 (P<.05). 치유 기간별로 임플란트 주변 골에서 칼륨 (K), 인 (P), 칼슘 (Ca), 티타늄 (Ti)의 분포를 EPMA로 보았을 때 빈도의 편향은 관찰되지 않았으며 2군과 3군에서 초기에 칼슘과 인이 증가되는 것이 관찰되었다. 이상의 결과로 볼 때 알칼리 및 대기 중에서 열처리로 표면 처리된 임플란트의 사용은 초기에 안정된 골유착에 도움을 주며 임플란트 식립 후 기능까지의 시간을 감소시킬 것으로 사료된다.

촉각센서를 이용한 근육평가의 신뢰도 조사 (Reliability of Muscle Evaluation with a Tactile Sensor System)

  • 오영락;이동주;김성환;김미은;김기석
    • Journal of Oral Medicine and Pain
    • /
    • 제30권3호
    • /
    • pp.337-344
    • /
    • 2005
  • 악골과 구강은 피부, 근육, 입술, 뺨, 치은, 혀, 점막 등의 다양한 연조직으로 구성되어 있으며, 악구강계의 정상적인 기능을 평가하기 위해서는 각 연조직의 특성을 이해하는 것이 중요하다. 또한 각 조직의 질병 이환 여부와 치료 전후의 상태를 평가, 비교하는 것도 중요하므로 이를 평가하기 위한 다양한 연구들이 진행되어 왔다. 특히, 최근에는 촉각센서(tactile sensor)라는 새로운 기기가 개발되면서 연조직의 탄성 및 경도와 관련된 특성을 밝히려는 시도가 이루어지고 있다. 이 연구의 목적은 구강안면동통과 관련성이 높은 측두근, 교근 및 승모근의 근육상태를 촉각센서를 이용하여 평가함에 있어 먼저 술자간, 술자내 신뢰도를 조사하고자 하였다. 건강한 성인 남자 5명의 좌우측 전측두근, 교근 및 상부승모근의 경도와 탄성을 촉각센서(Venustron II, Axiom Co., Japan)를 이용하여 측정하였다. 각 근육당 표본수는 10개였다. 피검자를 의자에 바로 앉힌 다음, 피검자의 안면피부에 촉각센서의 probe를 각 근육에 수직되게 위치시켜 근육의 경도와 탄성을 측정하였다. 교근과 전측두근은 수축시 최대풍융부를 촉진하여 펜으로 표시하고 치아가 가볍게 닿게 한 안정 상태에서 센서의 probe를 근육의 최대풍융부에 수직으로 motor-drive를 이용하여 눌러서 측정하였다. 승모근은 상부를 촉진하여 표시한 다음, 동일한 방법으로 측정하였다. 피검자에 대하여 같은 날 2명의 술자가 각각 근육의 경도와 탄성의 변화를 측정하여 술자간 신뢰도 조사하였고, 2일 뒤 다시 한번 측정하여 술자내 신뢰도를 조사하였으며 통계분석에는 Correlation coefficient 및 Paired t-test를 이용하였다. 실험결과, 전측두근, 교근 및 상부승모근의 경도와 탄성에 대한 두 검사자의 평균값은 유의한 차이를 보이지 않았으며 서로 높은 상관관계를 보여주었다. 또한 한 검사자가 2일의 간격을 두고 시행한 두 번의 검사에서도 두 검사간 평균값은 유의한 차이를 보이지 않았으며 서로 높은 상관관계를 보여주었다. 즉, 촉각센서를 사용한 교근과 전측두근 및 상부승모근의 경도와 탄성의 평가는 높은 술자간, 술자내 신뢰도를 보여주었으며, 두경부 근육을 정량적으로 평가할 수 있는 재현성 높고 효과적인 검사법이라고 할 수 있다.

나노메니퓰레이터를 이용한 나노선의 특성평가 (Applications of Nanomanipulator in Nanowires)

  • 윤상원;서종현;안재평;성태연;이건배
    • 한국분말재료학회지
    • /
    • 제16권2호
    • /
    • pp.138-145
    • /
    • 2009
  • FIB와 나노메니퓰레이터를 이용한 다양한 nano manufacturing을 통해 단일 나노선 소자제작 및 평가가 가능하였으며 또한 나노물질 자체의 전기적, 기계적 특성 평가를 수행할 수 있었다. 나노메니퓰레이터를 나노선에 직접 접촉시켜 전기적 특성을 평가하는 기술은 STA 등과 함께 사용될 때 높은 신뢰도를 갖는 신호를 얻을 수 있었다. 특히, 이를 이용한 나노 소재 특성 평가기술은 소자제작 시간을 단축시킬 수 있고 패턴닝으로부터 화학적 오염을 줄일 수 있는 장점을 갖고 있었다. 또한 FIB와 나노메니퓰레이터를 적절히 이용하면 나노인장시험기로서 활용이 가능하였으며 나노선의 기계적 특성을 본격적으로 평가할 수 있었다. 본 연구의 나노인장시험으로부터 얻은 인장실험 및 TEM분석으로부터 Au 및 Pd 나노선의 인장 및 파괴거동을 직접적으로 관찰할 수 있었다. Au 나노선은 인장초기에 {111}<112> 쌍정이 생성되고 나노선의 직경이 감소하다가 더 이상 인장응력을 수용할 수 없게되면 <110> 축으로부터 <002> 방향으로 재배열하는 방식으로 네킹이 형성되며 최종적으로 결정축 재배열 이후에는 슬립에 의한 파괴가 진행된다. Pd 나노선의 경우에는 Au와는 전혀 다른 파괴거동을 보였다. 먼저 네킹없이 <002> 축으로의 재배열 현상이 관찰되며 이후 cross-slip에 의한 변형을 하였다. 두 나노선 모두 인장 응력이 가해지면 네킹 부분을 중심으로 한 부분에서만 변형이 일어나며 다른 부분에서는 아무런 변형을 찾아 볼 수 없었다.

Complementary Split Ring Resonator(CSRR)를 이용한 포도당과 염화나트륨 수용액의 비침습적 구별 (Noninvasive Method to Distinguish between Glucose and Sodium Chloride Solution Using Complementary Split-Ring Resonator)

  • 장초롬;박진관;윤기호;육종관
    • 한국전자파학회논문지
    • /
    • 제29권4호
    • /
    • pp.247-255
    • /
    • 2018
  • 본 논문에서는 complementary split ring resonator(CSRR)을 이용하여 마이크로파 대역에서 비침습적으로 포도당 수용액과 염화나트륨 수용액을 구별하였다. 개방형 동축 프로브로 측정한 두 수용액의 전기적 특성을 기반으로 구별이 유리한 주파수에서 동작하는 CSRR을 설계, 제작하였다. 그리고 공진기의 전기장이 강하게 형성되는 부분에 수용액을 집중시키기 위해 PDMS mold를 제작하였고, 라미네이트 필름으로 수용액과 공진기의 접촉을 방지하였다. 두 수용액의 농도는 인체 혈당 농도 범위인 400 mg/dL까지 100 mg/dL 단위로 나누었고, $50{\mu}L$의 수용액으로 실험하였다. 공진 주파수에서 포도당 수용액과 염화나트륨 수용액의 투과계수($S_{21}$)를 측정한 결과, 100 mg/dL 농도 변화 대비 각각 -0.06 dB, 0.14 dB 변하는 것을 확인하였고, 상반된 경향을 통해 두 수용액의 농도에 따른 $S_{21}$의 변화를 선택적으로 구별하였다.

황동제 주방기구에서 유해중금속의 용출기작에 관한연구 (Migration Mechanism of Hazard Elements from Brass Kitchenwares)

  • 이광호;권기성;전대훈;최병희;김성욱;이선희;이철원
    • 한국포장학회지
    • /
    • 제5권2호
    • /
    • pp.24-30
    • /
    • 1999
  • 구이용 불판인 주방용 기구에 사용되는 황동제에서 Pb, Cd, Cu, Zn, Sn등 유해 중금속의 용출과 메카니즘에 대하여 연구하였다. 황동을 대표금속으로 선정하여 용출 온도 (30, 60, 80, $95^{\circ}C$), pH (2.5, 4.3, 6.0, 7.0) 및 시간 (30, 90, 180, 360분)에 따른 금속 용출량 조사에서 온도 및 pH 변화에 따른 시험결과, $95^{\circ}C$, pH 2.5인 조건에서 용출이 가장 많았던 반면, 용출 시간별 시험에서는 180분 이후까지 Pb가 용출된 후 평형 상태를 유지하였다. 납이 용출되는 가시적 현상은 SEM을 통하여 확인할 수 있었다. 황동의 경우, 재질중의 Pb 함량과 용출량과의 관계를 규명하기 위해 Pb 함량별 10종 (0, 0.02, 0.09, 0.1, 0.2, 0.5, 0.9, 1.7, 5.4, 9.2%(w/w))의 시편를 제작하여 4% 초산, $95^{\circ}C$, 30분에서 시험한 결과, 용출규격인 중금속이 1.0 ppm (납으로서) 이하가 되기 위해서는 재질중 허용 Pb 함량은 0.2% 이하가 되어야 했다.

  • PDF