• Title/Summary/Keyword: Construction control system

Search Result 2,247, Processing Time 0.026 seconds

Evaluation of PTO Severeness for 78 kW-Class Tractor According to Disk Plow Tillage and Rotary Tillage (디스크플라우 및 로타리 작업에 따른 78 kW급 트랙터 PTO 가혹도 평가)

  • Kim, Wan Soo;Kim, Yong Joo;Park, Seong Un;Hong, Soon Jung;Kim, Yeon Soo
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.23-31
    • /
    • 2019
  • The purpose of this study was to evaluate the PTO severeness for an agricultural tractor during disk plow and rotary tillage. The PTO load measurement system was constructed with data acquisition and a PTO torquemeter. Field experiments were conducted at a combination of traveling speed (L3 Low, L3 High) and PTO speed (P1, P2). The load spectrum was generated using the rain-flow counting method, and the SWT method was used to consider the range and mean of the PTO load. The damage sum was calculated by applying a modified miner rule, which is a cumulative damage law. The relative severeness was expressed as the ratio of the lowest damage sum. Relative severeness was higher with the lower PTO gear stage, and higher driving gear stage and it was approximately 40-102 times higher for rotary tillage than disk plow tillage in the same gear stages. The relative severeness was 1010.12 in the rotary tillage under L3 High P1 based on the disk plow tillage under L3 Low P2.

Electricity Production from Fe[III]-reducing Bacterium Geobacter sulfurreducens in Microbial Fuel Cell (미생물 연료전지에서 Fe[III] 환원 미생물 Geobacter sulfurreducens를 이용한 전기 생산)

  • Lee, Yu-Jin;Oh, You-Kwan;Kim, Mi-Sun
    • Journal of Hydrogen and New Energy
    • /
    • v.19 no.6
    • /
    • pp.498-504
    • /
    • 2008
  • Metal-reducing bacterium, Geobacter sulfurreducens is available for mediator-less microbial fuel cell (MFC) because it has biological nanowires(pili) which transfer electrons to outside the cell. In this study, in the anode chamber of the MFC system using G. sulfurreducens, the concentrations of NaCl, sodium phosphate and sodium bicarbonate as electrolytes were mainly optimized for the generation of electricity from acetate. 0.4%(w/v) NaClO and 0.5M $H_2SO_4$ could be utilized for the sterilization of acrylic plates and proton exchange membrane (major construction materials of the MFC reactor), respectively. When NaCl concentration in anode phosphate buffer increased from 5 to 50 mM, power density increased from 6 to $20\;mW/m^2$. However, with increasing sodium phosphate buffer concentration from 5 to 50 mM, power density significantly decreased from 18 to $1\;mW/m^2$. Twenty-four mM sodium bicarbonate did not affect electricity generation as well as pH under 50 mM phosphate buffer condition. Optimized anode chamber of MFC using G. sulfurreducens generated relatively high power density ($20\;mW/m^2$) with the maximum coulombic efficiency (41.3%).

A Study on a Permissible Range of the Indicators to Manage Streetscapes by Dynamic Simulation - Focusing on Shape and Layout of Buildings - (동적 시뮬레이션에 의한 도시가로경관 관리지표의 허용범위 연구 - 건축물 형태 및 배치를 중심으로 -)

  • Kim, Doo-Wun;Byeon, Jae-Sang;Im, Seung-Bin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.35 no.6
    • /
    • pp.74-83
    • /
    • 2008
  • As urban residents' standard of living has recently risen, efforts to improve urban landscapes have increased. It is very important to manage streetscapes to improve the urban landscape because they are one of the essential elements in city construction and urban landscaping. This study focuses on the indicators that manage streetscapes more accurately and realistically. To achieve this purpose, this study used dynamic simulations considering shape and layout of buildings, the primary factors in streetscapes. This study can be summarized as follows: 1. Two indicators to manage streetscape were investigated in previous studies: one to increase visual openness and the other to reduce visual overstimulation. These indicators had high correlation with scenic beauty. Therefore, increasing openness and reducing overstimulation are essential to improve streetscapes. 2. Two household tower type buildings should be arranged along roadsides to increase openness and scenic beauty. However, low tower buildings with two household are not suitable along roadsides because they create monotony and intervals are needed between buildings. 3. To increase openness, the angled arrangement of buildings is suggested $75^{\circ}{\sim}90^{\circ}(105^{\circ}{\sim}135^{\circ})$ for low buildings, $30^{\circ}{\sim}45^{\circ}(135^{\circ}{\sim}150^{\circ})$ for mid-sized buildings, and $75^{\circ}{\sim}90^{\circ}(105^{\circ}{\sim}135^{\circ})$ for high buildings. 4. To reduce overstimulation, the height and setback control regulations should be at an angle of less than $45^{\circ}$. This study suggests more accurate management guidelines by organizing the indicators that could effectively manage streetscapes and by overcoming limitations of reality shown in a static simulation.

An Investigation for Air Pollutants Emitted from Small-Scale Incinerators in Highway Service Area (고속도로 휴게소의 소형소각로에서 배출되는 대기오염물질 조사)

  • Jang, Young-Kee;Choi, Sang-Jin;Kim, Kwan;Hong, Min-Sun;Choi, Join-In;Moon, Su-Ho;Kim, Soon-Tae;Kim, Seung-Do
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.539-546
    • /
    • 2002
  • The physicochemical properties of solid wastes generated from seven highway service areas, four branch offices, and one construction site were analyzed in concert with air pollutants including heavy metals emitted from near-by small-scale incinerators. The amount of solid wastes generated from highway areas has been increasing with recent increases in the number of highways and passengers. Twelve incinerators examined in this study generally had capacity smaller than 100 kg/hr, most of which were equipped with cyclone for dust removal. It was seen that the concentrations of the gas-phase air pollutants (e.g., SO$_2$, NO$_{x}$, HCl and H$_2$S) were above the acceptable emission standards except one or two sites. CO concentrations at all incinerators were also higher due to incomplete combustion. In addition, particulate matters showed concentration six times higher at their maximum. The results of heavy metal analysis showed that the concentrations of Cu, Cd, and Ni satisfied the emission standards. whereas Pb at one site and Zn at five sites exceeded the standards. Cr measurement results indicated that 9 of 12 incinerators had higher values than the standard; especially one branch office showed nine times higher than normal concentration. In order to satisfy more stringent emission standards in the near future, it is necessary to install air pollution control system and to develop an intensified management plan.n.

Compressive Strength Estimation Technique of Underwater Concrete Structures using Both Rebound Hardness and Ultrasonic Pulse Velocity Values (반발경도와 초음파속도를 이용한 수중 콘크리트 구조물의 압축강도 예측 기술)

  • Shin, Eun-Seok;Lee, Ji-Sung;Park, Seung-Hee;Han, Sang-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.118-125
    • /
    • 2014
  • As the earth's current global warming has caused elevation of sea water temperature, size of storms is foreseen to increase and consequently large damages on port facilities are to be expected. In addition, due to the improved processing efficiency of port cargo volume and increasing necessity for construction of eco-friendly port, demands for various forms of port facilities are anticipated. In this study, two kinds of nondestructive evaluation (NDE) techniques (rebound hardness and ultrasonic pulse velocity methods) are investigated for the effective maintenance of smart green harbor system. A new methodology to estimate the underwater concrete strengths is proposed and its feasibility is verified throughout a series of experimental works.

Study on the Design of a Rotary-type LSM and Test Equipment for Design Verification of LSM for Ultra-high-speed Train (초고속열차용 LSM 설계 검증을 위한 회전형 구조의 LSM 및 시험기 설계 연구)

  • Park, Chan-Bae
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.196-202
    • /
    • 2017
  • A very long test track is required for high-speed operation test of the real-scale Linear Synchronous Motor (LSM) for ultra-high-speed trains. The required length results in huge construction cost and economic loss if any error occurs during development. Therefore, validation study of the LSM design technology using a low-cost small-scale model must be carried out in the early research stages. It is possible to deduce an optimal winding method for the armature and determine the mechanical properties of the LSM through a performance tester that applies a rotary-type small-scale LSM model. In addition, it is possible to utilize previous research on LSM control systems. Therefore, a basic design model, comprising a rotary-type LSM tester that meets the requirements for the propulsion of 600km/h-class ultra-high-speed trains, is derived in this study. Finally, an optimal model, which has a stable structure under the condition of 1500rpm or more high-speed rotation, is derived by electromagnetic and mechanical stiffness analysis.

Hydration Heat and Strength Characteristics of Cement Mortar with Phase Change Materials(PCMs) (상전이물질을 혼입한 시멘트 모르타르의 수화발열 및 강도 특성 평가)

  • Jang, Seok-Joon;Kim, Byung-Seon;Kim, Sun-Woong;Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.665-672
    • /
    • 2016
  • This study is conducted to investigate the effect of phase change materials (PCM) on hydration heat and strength characteristics of cement mortar. Two types of Barium and Strontium-based PCMs were used in this study and the addition ratio of each PCM to the cement mortar ranged from 1% to 5% by cement weight. Flow test, semi-adiabatic temperature rise test, compressive strength and flexural strength test were carried out to examine the PCM effect on heat and mechanical properties of cement mortar. Test results indicated that PCMs used in this study were effective to control hydration heat of cement mortar, and Barium-based PCM slightly reduce flow value. The compressive and flexural strength of cement mortar with PCM decreased with increasing the adding mount of PCM. The prediction model for compressive strength of cement mortar with different addition levels of PCMs are suggested in this study.

A Study on Thermal Analytical Model for a Dry Dual Clutch (건식 듀얼 클러치의 열해석 모델에 대한 연구)

  • Liu, Hao;Lee, J.C.;Noh, Y.J.;Cho, J.H.;Lee, H.R.;Koh, J.E.;Kang, J.W.
    • Journal of Drive and Control
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The stability of friction characteristics and thermal management for a dry type dual clutch transmission (DCT) are inferior to those of a wet clutch. Too high temperature resulting from frequent engagement of DCT speeds up degradation or serious wear of the pressure plate or burning of the clutch disk lining. Even though it is significantly important to estimate the temperature of a dry double clutch (DDC) in real-time, few meaningful study of the thermal model of DDC has been known yet. This study presented a thermal analytical model of lumped parameters for a DDC by analyzing its each component firstly. Then a series of experimental test was carried out on the test bench with a patented temperature telemetry system to validate the proposed thermal model. The thermal model, whose optimal parameter values were found by optimization algorithm, was also simulated on the experimental test conditions. The simulation results of DDC temperature show consistency with the experiment, which validates the proposed thermal model of DDC.

The design of outlet in inter-cross slope with tunnel which it applied forming artificial ground (인공지반을 적용한 사교하는 사면에서의 터널 갱구부 설계)

  • Park, Chal-Sook;Kwan, Han;Lee, Kyu-Tak;Kim, Bong-Jae;Yun, Yong-Jin;Kim, Kwang-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1532-1548
    • /
    • 2008
  • The tunnel type spillways is under construction to increasing water reservoir capacity in Dae-am dam. The tunnel outlet was planned to be made after installing slope stabilization system on natural slope there. Generally, the tunnel outlet is made perpendicularly to the slope, but in this case, it had to be made obliquely to the slope for not interrupting flow of river. Because of excavation in condition of natural slope caused to deflecting earth pressure, the outlet couldn't be made. So, artificial ground made with concrete that it was constructed in the outside of tunnel for producing the arching effect which enables to make a outlet. We were planned tunnel excavation was carried out after artificial ground made. Artificial ground made by poor mix concrete of which it was planned that the thickness was at least 3.0m height from outside of tunnel lining and 30cm of height per pouring. Spreading and compaction was planned utilized weight of 15 ton roller machine. In order to access of working truck, slope of artificial ground was designed 1:1.0 and applied 2% slope in upper pert of it for easily drainage of water. In addition to, upper pert of artificial ground was covered with soil, because of impaction of rock fall from upper slope was made minimum. The tunnel excavation of the artificial ground was designed application with special blasting method that it was Super Wedge and control blasting utilized with pre-percussion hole.

  • PDF

Measurement of Noise and Evaluation of Noise Control Methods for Military Rifle Shooting Ranges (군 소화기 사격장 소음측정 및 소음저감 방안 평가)

  • Lee, Sang-Woo;Kim, Hee-Seok;Jeong, Sang-Jo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.123-132
    • /
    • 2009
  • Civil petitions and law suits against the military rifle shooting noise have been increased because many military shooting ranges are located near civilian residential area. In order to solve the noise problems, military have devised various methods. In this study, propagation properties of rifle shot through atmosphere were investigated. The military rifle shooting noise level at 5m from muzzle was between $l14{\sim}120dB$ in all directions. The noise level loom both backward and sideward away from system firing range consisting lines of 8 shooting locations were 90dB, when shots were all fired within 10 seconds. At present some of military bases established sound barriers, muzzle enclosures, silencers, and indoor shooting ranges to reduce noises and these prevention methods can reduce noise by $5{\sim}20dB,\;5{\sim}9dB,\;5{\sim}13dB,\;40{\sim}50dB$, respectively. Even though indoor shooting range has the best performance, it requires very expensive construction cost and has short length between target and shooter. In comparison, muzzle enclosure is cheap, but because it is installed in fixed position it can only be used in one shooting position. Therefore a commander should select appropriate methods to reduce military rifle shooting noise considering distance from residential area to the range, mission of military training, budget, etc.