Browse > Article

An Investigation for Air Pollutants Emitted from Small-Scale Incinerators in Highway Service Area  

Jang, Young-Kee (Department of Environmental Engineering, Suwon University)
Choi, Sang-Jin (Department of Environmental Engineering, Suwon University)
Kim, Kwan (Department of Environmental Engineering, Suwon University)
Hong, Min-Sun (School of Environmental¡¤Urban Engineering, Ajou University)
Choi, Join-In (School of Environmental¡¤Urban Engineering, Ajou University)
Moon, Su-Ho (School of Environmental¡¤Urban Engineering, Ajou University)
Kim, Soon-Tae (School of Environmental¡¤Urban Engineering, Ajou University)
Kim, Seung-Do (Department of Environmental Science, Hallym University)
Publication Information
Journal of Korean Society for Atmospheric Environment / v.18, no.6, 2002 , pp. 539-546 More about this Journal
Abstract
The physicochemical properties of solid wastes generated from seven highway service areas, four branch offices, and one construction site were analyzed in concert with air pollutants including heavy metals emitted from near-by small-scale incinerators. The amount of solid wastes generated from highway areas has been increasing with recent increases in the number of highways and passengers. Twelve incinerators examined in this study generally had capacity smaller than 100 kg/hr, most of which were equipped with cyclone for dust removal. It was seen that the concentrations of the gas-phase air pollutants (e.g., SO$_2$, NO$_{x}$, HCl and H$_2$S) were above the acceptable emission standards except one or two sites. CO concentrations at all incinerators were also higher due to incomplete combustion. In addition, particulate matters showed concentration six times higher at their maximum. The results of heavy metal analysis showed that the concentrations of Cu, Cd, and Ni satisfied the emission standards. whereas Pb at one site and Zn at five sites exceeded the standards. Cr measurement results indicated that 9 of 12 incinerators had higher values than the standard; especially one branch office showed nine times higher than normal concentration. In order to satisfy more stringent emission standards in the near future, it is necessary to install air pollution control system and to develop an intensified management plan.n.
Keywords
waste incinerator; emission; heavy metal;
Citations & Related Records
연도 인용수 순위
  • Reference
1 /
[ 환경부 ] / 대기오염·소음·진동 공정시험방법
2 /
[ 한국도로공사 ] / 한국도로공사Homepage
3 소형 소각시설의 문제점 및 개선방안에 대한 연구 /
[ 김철(등) ] / 한국폐기물학회지   과학기술학회마을
4 /
[ 환경부 ] / 국가폐기물 종합관리계획
5 서울지역 소형소각로의 대기오염물질 배출농도측정과 배출량 추정 /
[ 장영기(등) ] / 대한환경공학회지   과학기술학회마을
6 /
[ 환경부 ] / 환경통계연감
7 /
[ 김삼권 ] / 폐기물처리공정시험방법
8 /
[ 일본폐기물학회지 ] / 폐기물핸드북
9 /
[ George,T.(et al.) ] / Integrated Solid Waste Management Engineering Principles and Management Issues
10 /
[ 강승균 ] / 쓰레기 성상의 비교분석(국내 쓰레기 소각장을 기준)
11 고속도로휴게소 폐기물 발생추세에 대한 연구 /
[ 이의상;이주광 ] / 한국도로공사 연구보고서
12 /
[ 정재춘 ] / 폐기물처리