• Title/Summary/Keyword: Confirmation Method of Target Detection

Search Result 9, Processing Time 0.023 seconds

Confirmation Method of Target Detection for Vehicle Mounted Metal Detector

  • Jung, Byung-Min;Shin, Beom-Su;Chang, YuShin;Yang, DongWon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.49-54
    • /
    • 2016
  • In this paper, the confirmation method of target detection for the vehicle mounted metal detector (MD) has been described. The vehicle mounted MD with the arrayed 6 coils to detect the width of 2.4 m was demonstrated. It is important and necessary to inform the location of the objects detected by the MD. The confirmation method of target detection was verified by using the MD GUI and the analysis of the receive signal processing. The receive signal processing is performed by comparing the threshold and the difference of the signal calibrated at initial location and the signal detected at present location.

Reliable Measurement Selection for The Small Target Detection and Tracking in The IR Scanning Images (적외선 주사 영상에서 소형 표적의 탐지 및 추적을 위한 신뢰성 있는 측정치 선택 기법)

  • Yang, Yu-Kyung;Kim, Sung-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.75-84
    • /
    • 2008
  • A new automatic small target detection and tracking algorithm for the real-time IR surveillance system is presented. The automatic target detection and tracking algorithm of the real-time systems, requires low complexity and robust tracking performance in the cluttered environment. Linear-array and parallel-scan IR systems usually suffer from severe scan noise caused by the detector non-uniformity. After the spatial filtering and thresholding, this scan noise still remains as high amplitude clutter which degrades the target detection rate and tracking performance. In this paper, we propose a new feature which consists of area and validity information of a measurement. By adopting this feature to the measurements selection and track confirmation, we can increase the target detection rate and reduce both the track loss rate and false track rate. From the experimental results, we can validate the feasibility of the proposed method in the noisy IR images.

Rapid detection of deformed wing virus in honeybee using ultra-rapid qPCR and a DNA-chip

  • Kim, Jung-Min;Lim, Su-Jin;Kim, SoMin;Kim, MoonJung;Kim, ByoungHee;Tai, Truong A;Kim, Seonmi;Yoon, ByoungSu
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.4.1-4.9
    • /
    • 2020
  • Fast and accurate detection of viral RNA pathogens is important in apiculture. A polymerase chain reaction (PCR)-based detection method has been developed, which is simple, specific, and sensitive. In this study, we rapidly (in 1 min) synthesized cDNA from the RNA of deformed wing virus (DWV)-infected bees (Apis mellifera), and then, within 10 min, amplified the target cDNA by ultra-rapid qPCR. The PCR products were hybridized to a DNA-chip for confirmation of target gene specificity. The results of this study suggest that our method might be a useful tool for detecting DWV, as well as for the diagnosis of RNA virus-mediated diseases on-site.

Determination of Veterinary Antibiotic Residues: IV. Comparable Analytical Methods with EPA Methods 1694_A Review (시료 중 잔류 항생제 분석 방법: IV. EPA method 1694와 비교 가능한 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.670-699
    • /
    • 2016
  • In this study, 16 antibiotics were selected from among the top 30 veterinary antibiotics sold in South Korea in 2014, as well as from among the pharmaceuticals targeted by EPA method 1694, in order to review analytical methods for the detection of trace levels of antibiotics in environmental samples: surface water, soils, animal origin foods, and manures. LC-MS/MS was heavily used. In the chromatography for the detection of the selected antibiotics, the $C_{18}$ column was mostly used at the temperature of $30{\sim}40^{\circ}C$. Water and methanol/acetonitrile were commonly chosen as a nonpolar and a polar mobile phase, respectively. Gradient elution was applied to separate multiclass antibiotics. Volatile additives, such as formic acid, acetic acid, and ammonium acetate were mixed with the mobile phase to improve the ionization efficiency of analytes and the sensitivity in MS detection. Electrospray ionization (ESI) was widely used in the LC-MS/MS and positive ionization was preferred to determine the selected antibiotics. A protonated $[M+H]^+$ molecule was selected as a precursor ion, and its two transitions were analyzed, one for quantitative measurement and the other for confirmation. This study reviewed linearity of the calibration curve, recovery, repeatability, method detection limits (MDLs), and method quantification limits (MQLs) for each target compound used to validate the developed analytical methods.

Development and validation of a qualitative GC-MS method for methamphetamine and amphetamine in human urine using aqueous-phase ethyl chloroformate derivatization

  • Kim, Jiwoo;Sim, Yeong Eun;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.23-32
    • /
    • 2020
  • Methamphetamine (MA) is the most common and available drug of abuse in Korea and its primary metabolite is amphetamine (AP). Detection of AP derivatives, such as MA, AP, phentermine (PT), MDA, MDMA, and MDEA by the use of immunoassay screening is not reliable and accurate due to cross-reactivity and insufficient specificity/sensitivity. Therefore, the analytical process accepted by most urine drug-testing programs employs the two-step method with an initial screening test followed by a more specific confirmatory test if the specimen screens positive. In this study, a gas chromatography-mass spectrometric (GC-MS) method was developed and validated for confirmation of MA and AP in human urine. Urine sample (500 µL) was added with N-isopropylbenzylamine as internal standard and ethyl chloroformate as a derivatization reagent, and then extracted with 200 µL of ethyl acetate. Extracted samples were analysed with GC-MS in the SIM/ Scan mode, which were screened by Cobas c311 analyzer (Roche/Hitachi) to evaluate the efficiency as well as the compatibility of the GC-MS method. Qualitative method validation requirements for selectivity, limit of detection (LOD), precision, accuracy, and specificity/sensitivity were examined. These parameters were estimated on the basis of the most intense and characteristic ions in mass spectra of target compounds. Precision and accuracy were less than 5.2 % (RSD) and ±14.0 % (bias), respectively. The LODs were 3 ng/mL for MA and 1.5 ng/mL for AP. At the screening immunoassay had a sensitivity of 100% and a specificity of 95.1 % versus GC-MS for confirmatory testing. The applicability of the method was tested by the analysis of spiked urine and abusers' urine samples.

Method for Screening and Confirming Meldonium in Human Urine by High-Resolution Mass Spectrometry and Identification of Endogenous Interferences for Anti-Doping Testing

  • Kim, Yongseok;Jeong, Dawon;Min, Hophil;Sung, Changmin;Park, Ju-hyung;Son, Junghyun;Lee, Kang Mi;Kim, Ho Jun;Lee, Jaeick;Kwon, Oh-Seung;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.39-43
    • /
    • 2017
  • Meldonium is a drug for treating ischemia by expanding the arteries but it can also enhance the performance of sports players. The World Anti-Doping Agency (WADA) has included it in the list of prohibited substances since 2016. Meldonium is one of the challenging substances for anti-doping testing because it is difficult to recover by general liquid-liquid or solid phase extraction due to its permanent charge and high polarity. Therefore, high-performance liquid chromatography (HPLC) is currently used by injecting a diluted urine sample (known as the "dilute-and-shoot" strategy). There is no loss of target compounds in the extraction/cleanup procedure but its high matrix effect could interfere in their separation or detection from the endogenous urinary compounds. We report a single method using high-resolution mass spectrometry that can be used for both screening and confirmation, which follows the "dilute-and-shoot" strategy. In this method, the endogenous compounds' interfering peaks in the mass spectrum are separated at a high resolution of FWHM 140,000, and the results are suitable for substance detection following the WADA guidelines. The interferences in the obtained mass spectrum of the urine matrix are identified as acetylcholine, lysine, and glutamine by further analysis and database searching. Validation of the method is performed in routine anti-doping testing, and the limit of detection is 50 ng/mL. This method uses simple sample preparation and a general reverse phase HPLC column, and it can be easily applied to other substances.

Analysis of Volatile Organic Compounds in Sediments Using HS-GC/MS - Confirmation of Matrix Effects in External and Internal Standard Methods - (HS-GC/MS를 이용한 퇴적물 중 휘발성유기화합물 분석 - 외부 및 내부표준방법에서 매질영향 확인 -)

  • Shin, Myoung-Chul;Jung, Da-som;Noh, Hye-ran;Yu, Soon-ju;Seo, Yong-Chan;Lee, Bo-Mi
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.510-519
    • /
    • 2021
  • Volatile Organic Compounds (VOCs) in sediments, which can cause human health problems, have been monitored in Korea since 2014. Measured VOC concentrations can be affected by matrix type and the volatility of target substances. In this study, (1) VOCs volatility and the influence of matrix interference were confirmed, and (2) internal standards (IS) method was applied to improve analytical method. For these purposes, method detection limit (MDL), calibration linearity, precision and accuracy of VOCs were compared in various matrices using the IS. Some of VOCs in sediments showed different peak areas and reduced rates compared to water matrix. It was suggested that adsorption properties of sediments hindered the migration to vapor during heat pretreatment in headspace method. A calibration curve was created in clean sand. Recovery rates for the calibration curve method and IS applying method were 64.1~83.1% and 99.1~119.3%, respectively. Relative standard deviations ranged from 11.1% to 21.6% for the calibration curve method and those for IS ranged 4.7% to 13.7%. In case of real sediment, calibration curve and 1,2-Dichlorobenzene-d4 (ODCB) among IS were not suitable. The average recovery rate of Fluorobenzene (FBZ) increased by 56.4% and Relative Standard Deviation (RSD) by 4.7%. However, the recovery rate was increased in the samples with large values of igniting intensity. This study confirmed that influence of the matrix of VOCs in sediment, and addition of IS materials improved precision and accuracy. Although IS corrects volatilization and adsorption, it is recommended that more than two types of IS should be added rather than single.

Seroepidemiology of Hepatitis B Virus Infection in Healthy Korean Adults in Seoul (정상 성인에 있어서의 B형 간염 바이러스 감염에 관한 혈청역학적 연구)

  • Yoo, Keun-Young;Park, Byung-Joo;Ahn, Yoon-Ok
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.1 s.23
    • /
    • pp.89-98
    • /
    • 1988
  • While there have been not a few reports on the seroepidemiological characteristics of hepatitis B virus (HBV) infection in Korea, most of them, however, have had several limitations; operational definition of HBV infection, validity of detection methods of HBV serologic markers, size of the study population, and confirmation of the vaccination history against HBV, etc. In order to avoid such limitations, authors randomly selected 1,495 healthy adults among the 217,511 insured (target population) of Korean Medical Insurance Corporation, living in seoul, and tested HBV serologic markers by RIA method and conducted direct interview to them. Although HBV serologic markers (HBsAg, anti-HBs and anti-HBc) of all the subjects were tested, 392(26.2%) of interview failure cases and 361 vaccinee were excluded from the actual population. Finally, the serologic markers tested of 742 nonvaccinee (study population) only were analysed for the seroepidemiologic observation of the natural infection of HBV. The seroepidemiological characteristics of HBV infection in Korea were as follows ; 1. Point prevalence of HBs antigenemia was 11.7(9.1{\sim}14.3)% in male, which was slightly higher than that of female, 9.5($3.7{\sim}15.3$)%. This level was one of the highest among those of Asian-Pacific countries. Decreasing tendency of HBsAg prevalence alter the age of 50 was observed, which seems to be due to selective attrition of HBV chronic carriers among the healthy adults and/or to the limited-lasting duration of the HBs antigenemia, in part. 2. Point prevalence of anti-HBc(78.8% in male,50.9% in female) was higher than that of anti-HBs(65.2% in male,46.6% in female), respectively. And both of them were higher in male than in female. Increasing tendency of the prevalence of both antibodies was observed by age, which seems to be largely due to recurrent infection in adults and to some cumulative effect, in part, of their relatively longer-lasting duration. 3. The level of HBV infection defined by positive for at least one of the 3 serologic markers of HBV by RIA method was 84.7($81.8{\sim}87.6$)% in male and 61.2($51.9{\sim}70.5$)% in female, which was also one of the highest among those of Asian-Pacific countries. The proportion of susceptible population to HBV infection among healthy adults was 15.3% in male and 38.8% in female. 4. The relative frequency of current or past infection and chronic carrier among HBV infected person was estimated. The currently or past infected was estimated 75.7% in male and 71.8% in female, and chronic carrier state, 13.8% in male and 14.1% in female. The analysis of the geometric mean of the antibody titer in anti-HBs positive sera indicated also to be compatible with the above findings, suggesting that active, even though inapparent, infection of HBV occur so frequently among healthy adults in Korea.

  • PDF

Simultaneous Detection of Seven Phosphoproteins in a Single Lysate Sample during Oocyte Maturation Process (난자성숙 과정의 단일 시료에서 일곱 가지 인산화 단백질의 동시 분석 방법)

  • Yoon, Se-Jin;Kim, Yun-Sun;Kim, Kyeoung-Hwa;Yoon, Tae-Ki;Lee, Woo-Sik;Lee, Kyung-Ah
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.3
    • /
    • pp.187-197
    • /
    • 2009
  • Objective: Phosphorylation and dephosphorylation of proteins are important in regulating cellular signaling pathways. Bead-based multiplex phosphorylation assay was conducted to detect the phosphorylation of seven proteins to maximize the information obtained from a single lysate of stage-specific mouse oocytes at a time. Methods: Cumulus-oocyte complexes (COCs) were cultured for 2 h, 8 h, and 16 h, respectively to address phosphorylation status of seven target proteins during oocyte maturation process. We analyzed the changes in phosphorylation at germinal vesicle (GV, 0 h), germinal vesicle breakdown (GVBD, 2 h), metaphase I (MI, 8 h), and metaphase II (MII, 16 h in vitro or in vivo) mouse oocytes by using Bio-Plex phosphoprotein assay system. We chose seven target proteins, namely, three mitogen-activated protein kinases (MAPKs), ERK1/2, JNK, and p38 MAPK, and other 4 well known signaling molecules, Akt, GSK-$3{\alpha}/{\beta}$, $I{\kappa}B{\alpha}$, and STAT3 to measure their phosphorylation status. Western blot analysis and kinase inhibitor treatment for ERK1/2, JNK, and Akt during in vitro maturation of oocytes were conducted for the confirmation. Results: Phosphorylation of ERK1/2, JNK, p38 MAPK and STAT3 was increased over 3 folds up to 20 folds, while phosphorylation of the other three signal molecules, Akt, GSK-$3{\alpha}/{\beta}$, and $I{\kapa}B{\alpha}$ was less than 3 folds. All of these results except for Akt were statistically significant (p<0.05). Conclusion: This is the first report on the new and valuable method measuring many phosphoproteins simultaneously in one minute sample such as oocyte lysates. All of the three MAPKs, ERK1/2, JNK, and p38 MAPK are involved in the process of mouse oocyte maturation. In addition, STAT3 might be important regulator of oocyte maturation, while Akt phosphorylation at Serine 473 may not be involved in the regulation of oocyte maturation.