• 제목/요약/키워드: Computed tomography (CT), three-dimensional

검색결과 275건 처리시간 0.027초

골형태분석법과 micro-CT를 이용한 골소주 특성에 대한 연구 (Study of bony trabecular characteristics using bone morphometry and micro-CT)

  • 송영한;이완;이창진;지정현;이병도
    • Imaging Science in Dentistry
    • /
    • 제37권1호
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose : The research was done to investigate the effectiveness of 2D bony morphometry and microstructure of micro-computed tomography (micro-CT) on the osteoporotic bony change. We performed the bone morphometric analysis of proximal femur in ovariectomized rabbits with BMD and micro-CT examination. Materials and Methods : Twenty-one female (Newzealand, about 16 weeks old, 2.9-3.4kg) rabbits were used. Three rabbits were sacrificed on the day when experiment began (Baseline). The remaining 18 rabbits were divided into two groups. One group was ovariectomized bilaterally (OVX) and the other animals were subjected to sham operation (Sham). Bone specimens were obtained from the right and left femur of sacrificed rabbits. At intervals of 1, 2, 3, 5, 6 months respectively, BMD tests were performed on the proximal femur by using PIXlmus 2 (GE Lunar Co. USA), 2-dimensional bone morphometric analysis by custome computer program and 2D/3D bone structure analysis by micro-CT (Skyscan 1072, Antwerpen, Belgium). Statistical analysis was carried out for the correlation between bone morphometry, micro-CT and BMD Result : BV/TV, Tb.Th, Tb.N of micro-CT parameters showed higher values in sham group than OVX group. N.Nd/Ar.RI, N.NdNd, N.NdTm, N. TmTm, PmB/Ar.RI, 3-D BoxSlope of 2D morphometric parameters showed higher values in Sham group than OVX group. The micro-CT parameters of Tb.Sp, Tb.N were statistically significant correlated with BMD respectively. Several 2D morphometric parameters were statistically significant correlated with BMD respectively. Conclusion : Several parameters of 2D bony morphometry and micro-CT showed effective aspects on the osteoporotic bony change.

  • PDF

3D-CT를 이용한 골격성 III급 개방교합자의 악교정 수술 전, 후 설골 및 상기도의 변화 (The structural change in the hyoid bone and upper airway after orthognathic surgery for skeletal class III anterior open bite patients using 3-dimensional computed tomography)

  • 이윤섭;백형선;이기준;유형석
    • 대한치과교정학회지
    • /
    • 제39권2호
    • /
    • pp.72-82
    • /
    • 2009
  • 본 연구는 골격성 III급 개방교합자의 악교정 수술 전, 후 설골과 상기도의 변화를 3D-CT를 이용하여 관찰하고 이를 정상교합자와 비교하기 위하여 시행하였다. 전치부 개방교합을 동반한 골격성 III급 부정교합으로 진단되어 악교정 수술을 받은 환자 중 12명을 선정 후, 3D-CT를 통해 설골과 상기도의 3차원 입체영상을 분석하여, 악교정 수술 전, 후의 설골의 위치 변화 및 상기도의 부피 변화를 살펴보고, 이의 결과를 정상교합자 10명과 비교하였다. 설골은 골격성 III급 개방교합군에서 악교정 수술 전에 정상교합군의 설골에 비해 전방에 위치하고 있었고 악교정 수술 후 설골은 후, 상방으로 변화하였으나 유의성은 관찰되지 않았다. Hyoid plane과 mandibular plane이 이루는 각은 악교정 수술전의 골격성 III급 개방교합군이 정상교합군보다 큰 값을 나타내었고, 악교정 수술 후에는 그 차이가 더욱 증가하였다. 골격성 III급 개방교합군의 상기도 부피는 정상교합자보다 작으며 이는, 악교정수술 후에 더욱 감소하였다. 3차원 영상 분석 결과, 골격성 III급 개방교합자의 상기도는 정상교합자에 비해 좁으며, 하악골 후퇴술 이후 더욱 감소하기 때문에 이는 수술적 개선의 안정성에 영향을 줄 수 있음을 알 수 있었다.

Development of Computer Aided 3D Model From Computed Tomography Images and its Finite Element Analysis for Lumbar Interbody Fusion with Instrumentation

  • Deoghare, Ashish;Padole, Pramod
    • International Journal of CAD/CAM
    • /
    • 제9권1호
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to clarify the mechanical behavior of human lumbar vertebrae (L3/L4) with and without fusion bone under physiological axial compression. The author has developed the program code to build the patient specific three-dimensional geometric model from the computed tomography (CT) images. The developed three-dimensional model provides the necessary information to the physicians and surgeons to visually interact with the model and if needed, plan the way of surgery in advance. The processed data of the model is versatile and compatible with the commercial computer aided design (CAD), finite element analysis (FEA) software and rapid prototyping technology. The actual physical model is manufactured using rapid prototyping technique to confirm the executable competence of the processed data from the developed program code. The patient specific model of L3/L4 vertebrae is analyzed under compressive loading condition by the FEA approach. By varying the spacer position and fusion bone with and without pedicle instrumentation, simulations were carried out to find the increasing axial stiffness so as to ensure the success of fusion technique. The finding was helpful in positioning the fusion bone graft and to predict the mechanical stress and deformation of body organ indicating the critical section.

흉추 CT 영상으로부터 사면체 요소망의 자동생성 (Tetrahedral Mesh Generation from CT Images of Thoracic Vertebra)

  • 박정민;권기환;전성재;채수원;이관행;이태수;서중근;박정율
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.150-153
    • /
    • 2002
  • The use of the finite element method for biomechanical analysis is increasing rapidly in recent years. Since biomechanical models are usually in very complex shapes, it takes a lot of time and efforts to build reasonable finite element models. In this paper, a new tetrahedral meshing algorithm from the series of 2-D computed tomography(CT) images has been proposed. In this scheme, the planar sections of three-dimensional objects and the side surfaces between two planar sections are triangulated first, and then an advancing front algorithm is employed to construct tetrahedral elements by using basic operators. A sample finite element model for thoracic vertebra is presented.

  • PDF

딥러닝 기반 균열 추출 기법을 통한 수압 파쇄 균열 형상 분석 (Morphological Analysis of Hydraulically Stimulated Fractures by Deep-Learning Segmentation Method)

  • 박지민;김광염;윤태섭
    • 한국지반공학회논문집
    • /
    • 제39권8호
    • /
    • pp.17-28
    • /
    • 2023
  • 본 연구에서는 화강암 시편을 대상으로 파쇄 유체의 점성과 주입 속도를 변화시키며 실내 수압 파쇄 실험을 수행하였고, 3D X-ray CT 촬영을 통해 파쇄 후 시편 내부를 관찰하였다. 이미지 처리에 탁월한 성능을 보이는 합성곱 신경망(Convolutional Neural Network, CNN) 기반 Nested U-Net 모델 구조를 활용하여 CT 이미지 내 수압 파쇄 균열 추출을 수행하였고, 복잡한 형상의 미세균열을 정교하게 추출할 수 있었다. CNN 기반 모델로 추출된 균열을 3차원으로 재구성하여 균열의 부피, 두께, 굴곡도, 균열면 거칠기를 분석하였다. 그 결과 파쇄 유체의 점성이 클수록 균열 부피와 두께가 증가하였고, 굴곡도와 균열면의 거칠기가 감소하는 경향을 보였다. 또한 균열면의 굴곡도와 거칠기 이방성이 존재함을 확인할 수 있었다. 본 연구는, CNN 기반의 균열 추출 모델을 활용해 전통적인 이미지 처리 방법보다 정교한 균열 추출을 수행하고, 이를 기반으로 수압 파쇄 균열의 정량 분석을 성공적으로 수행하였다.

Three-dimensional symmetry and parallelism of the skeletal and soft-tissue poria in patients with facial asymmetry

  • Kim, Min-Gun;Lee, Jin-Woo;Cha, Kyung-Suk;Chung, Dong-Hwa;Lee, Sang-Min
    • 대한치과교정학회지
    • /
    • 제44권2호
    • /
    • pp.62-68
    • /
    • 2014
  • Objective: The purpose of this study was to examine the symmetry and parallelism of the skeletal and soft-tissue poria by three-dimensional (3D) computed tomographic (CT) imaging. Methods: The locations of the bilateral skeletal and soft-tissue poria in 29 patients with facial asymmetry (asymmetric group) and 29 patients without facial asymmetry (symmetric group) were measured in 3D reconstructed models of CT images by using a 3D coordinate system. The mean intergroup differences in the anteroposterior and vertical angular deviations of the poria and their anteroposterior and vertical parallelism were statistically analyzed. Results: The symmetric and asymmetric groups showed significant anteroposterior angular differences in both the skeletal and the soft-tissue poria (p = 0.007 and 0.037, respectively; Mann-Whitney U-test). No significant differences in the anteroposterior and vertical parallelism of the poria were noted ($p{\leq}0.05$; Wilcoxon signed-rank test). Conclusions: In general, the skeletal poria are parallel to the soft-tissue poria. However, patients with facial asymmetry tend to have asymmetric poria.

Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

  • Kang, Sung-Won;Lee, Woo-Jin;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • 제45권1호
    • /
    • pp.7-13
    • /
    • 2015
  • Purpose: We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods: The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results: VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion: It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

CBCT를 이용한 3차원 안면비대칭분석 (3D Analysis of Facial Asymmetry using CBCT)

  • 윤숙자
    • 대한치과의사협회지
    • /
    • 제48권10호
    • /
    • pp.724-728
    • /
    • 2010
  • Accurate analysis of facial asymmetry prior to any orthognathic or orthodontic treatment plan is essential in ensuring good treatment result. Dental CBCT (Cone-beam Computed Tomography) provides as actual three-dimensional measurements of distance and angle without any radiographic magnification as medical CT provides, while its field of view is limited to the oral and maxillofacial area. CBCT is a useful tool for the diagnosis of facial asymmetry. The coordinates of facial landmarks are obtained from the 3D reconstruction software which enables the establishment of perpendicular planes and the identification of the landmarks. Then, the bilateral discrepancies of the landmarks are obtained as spherical polar coordinates which can show the amount of asymmetry and its direction. A method of 3D analysis of facial asymmetry using CBCT is introduced in this report.

Evaluation of Tracheobronchial Diseases: Comparison of Different Imaging Techniques

  • Qihang Chen;Jin Mo Goo;Joon Beom Seo;Myung Jin Chung;Yu-Jin Lee;Jung-Gi Im
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.135-141
    • /
    • 2000
  • Objective: To compare the clinical utility of the different imaging techniques used for the evaluation of tracheobronchial diseases. Materials and Methods: Forty-one patients with tracheobronchial diseases [tuberculosis (n = 18), bronchogenic carcinoma (n = 10), congenital abnormality (n = 3), post-operative stenosis (n = 2), and others (n = 8)] underwent chest radiography and spiral CT. Two sets of scan data were obtained: one from routine thick-section axial images and the other from thin-section axial images. Multiplanar reconstruction (MPR) and shaded surface display (SSD) images were obtained from thin-section data. Applying a 5-point scale, two observers compared chest radiography, routine CT, thin-section spiral CT, MPR and SSD imaging with regard to the detection, localization, extent, and characterization of a lesion, information on its relationship with adjacent structures, and overall information. Results: SSD images were the most informative with regard to the detection (3.95±0.31), localization (3.95±0.22) and extent of a lesion (3.85±0.42), and overall information (3.83±0.44), while thin-section spiral CT scans provided most information regarding its relationship with adjacent structures (3.56±0.50) and characterization of the lesion (3.51±0.61). Conclusion: SSD images and thin-section spiral CT scans can provide valuable information for the evaluation of tracheobronchial disease.

  • PDF

3차원 의료영상진단기기를 이용한 가상 전립선 용적 측정 (Measurement of Prostate Phantom Volume Using Three-Dimensional Medical Imaging Modalities)

  • 성열훈;주용현;최보영
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권4호
    • /
    • pp.285-291
    • /
    • 2010
  • Recently, advance on various modalities of diagnosing, prostate volume estimation became possible not only by the existing two-dimension medical images data but also by the three-dimensional medical images data. In this study, magnetic resonance image (MRI), computer tomography (CT) and ultrasound (US) were employed to evaluate prostate phantom volume measurements for estimation, comparison and analysis. For the prostate phantoms aimed at estimating the volume, total of 17 models were developed by using devils-tongue jelly and changing each of the 5ml of capacity from 20ml to 100ml. For the volume estimation through 2D US, the calculation of the diameter with C9-5Mhz transducer was conducted by ellipsoid formula. For the volume estimation through 3D US, the Qlab software (Philips Medical) was used to calculate the volume data estimated by 3D9-3Mhz transducer. Moreover, the images by 16 channels CT and 1.5 Tesla MRI were added by the method of continuous cross-section addition and each of imaginary prostate model's volume was yielded. In the statistical analysis for comparing the availability of volume estimation, the correlation coefficient (r) was more than 0.9 for all indicating that there were highly correlated, and there were not statistically significant difference between each of the correlation coefficient (p=0.001). Therefore, the estimation of prostate phantom volume using three-dimensional modalities of diagnosing was quite closed to the actual estimation.