• 제목/요약/키워드: Computed tomography

검색결과 5,176건 처리시간 0.048초

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제14권1호
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Therapeutic Angiogenesis by Intramyocardial Injection of pCK-VEGF165 in Pigs (돼지에서 pCK-VEGF165의 심근내 주입에 의한 치료적 혈관조성)

  • Choi Jae-Sung;Han Woong;Kim Dong Sik;Park Jin Sik;Lee Jong Jin;Lee Dong Soo;Kim Ki-Bong
    • Journal of Chest Surgery
    • /
    • 제38권5호
    • /
    • pp.323-334
    • /
    • 2005
  • Background: Gene therapy is a new and promising option for the treatment of severe myocardial ischemia by therapeutic angiogenesis. The goal of this study was to elucidate the efficacy of therapeutic angiogenesis by using VEGF165 in large animals. Material and Method: Twenty-one pigs that underwent ligation of the distal left anterior descending coronary artery were randomly allocated to one of two treatments: intramyocardial injection of pCK-VEGF (VEGF) or intramyocardial injection of pCK-Null (Control). Injections were administered 30 days after ligation. Seven pigs died during the trial, but eight pigs from VEGF and six from Control survived. Echo-cardiography was performed on day 0 (preoperative) and on days 30 and 60 following coronary ligation. Gated myocardial single photon emission computed tomography imaging (SPECT) with $^{99m}Tc-labeled$ sestamibi was performed on days 30 and 60. Myocardial perfusion was assessed from the uptake of $^{99m}Tc-labeled$ sestamibi at rest. Global and regional myocardial function as well as post-infarction left ventricular remodeling were assessed from segmental wall thickening; left ventricular ejection fraction (EF); end systolic volume (ESV); and end diastolic volume (EDV) using gated SPECT and echocardiography. Myocardium of the ischemic border zone into which pCK plasmid vector had been injected was also sampled to assess micro-capillary density. Result: Micro-capillary density was significantly higher in the VEGF than in Control ($386\pm110/mm^{2}\;vs.\;291\pm127/mm^{2};\;p<0.001$). Segmental perfusion increased significantly from day 30 to day 60 after intramyocardial injection of plasmid vector in VEGF ($48.4\pm15.2\%\;vs.\;53.8\pm19.6\%;\;p<0.001$), while no significant change was observed in the Control ($45.1\pm17.0\%\;vs.\;43.4\pm17.7\%;\;p=0.186$). This resulted in a significant difference in the percentage changes between the two groups ($11.4\pm27.0\%\;increase\;vs.\;2.7\pm19.0\%\;decrease;\;p=0.003$). Segmental wall thickening increased significantly from day 30 to day 60 in both groups; the increments did not differ between groups. ESV measured using echocardiography increased significantly from day 0 to day 30 in VEGF ($22.9\pm9.9\;mL\;vs.\;32.3\pm9.1\;mL;\; p=0.006$) and in Control ($26.3\pm12.0\;mL\;vs.\;36.8\pm9.7\;mL;\;p=0.046$). EF decreased significantly in VEGF ($52.0\pm7.7\%\;vs.\;46.5\pm7.4\%;\;p=0.004$) and in Control ($48.2\pm9.2\%\;vs.\;41.6\pm10.0\%;\;p=0.028$). There was no significant change in EDV. The interval changes (days $30\~60$) of EF, ESV, and EDV did not differ significantly between groups both by gated SPECT and by echocardiography. Conclusion: Intramyocardial injection of pCK-VEGF165 induced therapeutic angiogenesis and improved myocardial perfusion. However, post-infarction remodeling and global myocardial function were not improved.

Off Pump Total Arterial Myocardial Revascularization (동맥 도관만을 이용하여 체외심폐순환 없이 시행한 관상동맥우회술)

  • Youn Young Nam;Lee Kyo Joon;Lee Gy Jong;Joo Hyun Chul;Lim Sang Hyun;Kim Seung Ho;Kwak Young Lan;Yoo Kyung Jong
    • Journal of Chest Surgery
    • /
    • 제38권5호
    • /
    • pp.349-356
    • /
    • 2005
  • Background: Arterial conduits using in coronary artery bypass grafting (CABG) have been known a great long term patency rates, and improved short and long term clinical outcomes. It has been reported that Off pump CABG has better clinical results than CABG using cardiopulmonary bypass. To evaluate the advantage of arterial conduits over venous conduits and to avoid the adverse effects of cardiopulmonary bypass, we performed total arterial Off pump CABG. Material and Method: From January 2001 to October 2004, Off pump CABG using only arterial conduits was performed on 325 patients with a mean age of $59.3\pm11.9$ years ($36\~83$). Mean ejection fraction was $55.4\pm14.0\%\;(15\~86).$ Angiography showed left main disease or triple-vessel disease in $81.9\%$ of the patients. Indications of using arterial conduits was stenosis $\ge50\%$ of left anterior descending artery, stenosis $\ge80\%$ of branches of left circumflex artery, and stenosis $\ge90\%$ of right coronary artery and its branches. Multi-slice computed tomography was performed on 194 patients to evaluate the short term patency rates. Result: A total of 928 distal anastomoses were performed and the average anastomoses per a patient were $2.86\pm0.78$. There was 1 operative mortality. Postoperative complications were mediastinitis in 6 patients ($1.8\%$), renal failure in 4 patients ($1.2\%$), perioperative myocardial infarction in 3 patients ($0.9\%$), reoperation for bleeding in 3 patients ($0.9\%$). There was no postoperative stroke. Patency rate of arterial conduits was $99.3\%$ (581/585). There were 4 stenoses or competitive flows in 2 radial arteries and 2 right internal mammary arteries. Conclusion: Total arterial Off pump CABG appears to be safe, showing a low surgical mortality and morbidity and excellent short term patency rates of arterial conduits.

Computed Tomography-guided Localization with a Hook-wire Followed by Video-assisted Thoracic Surgery for Small Intrapulmonary and Ground Glass Opacity Lesions (폐실질 내에 위치한 소결질 및 간유리 병변에서 흉부컴퓨터단층촬영 유도하에 Hook Wire를 이용한 위치 선정 후 시행한 흉강경 폐절제술의 유용성)

  • Kang, Pil-Je;Kim, Yong-Hee;Park, Seung-Il;Kim, Dong-Kwan;Song, Jae-Woo;Do, Kyoung-Hyun
    • Journal of Chest Surgery
    • /
    • 제42권5호
    • /
    • pp.624-629
    • /
    • 2009
  • Background: Making the histologic diagnosis of small pulmonary nodules and ground glass opacity (GGO) lesions is difficult. CT-guided percutaneous needle biopsies often fail to provide enough specimen for making the diagnosis. Video-assisted thoracoscopic surgery (VATS) can be inefficient for treating non-palpable lesions. Preoperative localization of small intrapulmonary lesions provides a more obvious target to facilitate performing intraoperative. resection. We evaluated the efficacy of CT-guided localization with using a hook wire and this was followed by VATS for making the histologic diagnosis of small intrapulmonary nodules and GGO lesions. Material and Method: Eighteen patients (13 males) were included in this study from August 2005 to March 2008. 18 intrapulmonary lesions underwent preoperative localization by using a CT-guided a hook wire system prior to performing VATS resection for intrapulmonary lesions and GGO lesions. The clinical data such as the accuracy of localization, the rate of conversion-to-thoracotomy, the operation time, the postoperative complications and the histology of the pulmonary lesion were retrospectively collected. Result: Eighteen VATS resections were performed in 18 patients. Preoperative CT-guided localization with a hook-wire was successful in all the patients. Dislodgement of a hook wire was observed in one case. There was no conversion to thoracotomy, The median diameter of lesions was 8 mm (range: $3{\sim}15\;mm$). The median depth of the lesions from the pleural surfaces was 5.5 mm (range: $1{\sim}30\;mm$). The median interval between preoperative CT-guided with a hook-wire and VATS was 34.5 min (range: ($10{\sim}226$ min). The median operative time was 43.5.min (range: $26{\sim}83$ min). In two patients, clinically insignificant pneumothorax developed after CT-guided localization with a hook-wire and there were no other complications. Histological examinations confirmed 8 primary lung cancers, 3 cases of metastases, 3 cases of inflammation, 2 intrapulmonary lymph nodes and 2 other benign lesions. Conclusion: CT-guided localization with a hook-wire followed by VATS for treating small intrapulmonary nodules and GGO lesions provided a low conversion thoracotomy rate, a short operation time and few localization-related or postoperative complications. This procedure was efficient to confirm intrapulmonary lesions and GGO lesions.

The Study on the Independent Predictive Factor of Restenosis after Percutaneous Coronary Intervention used Drug-Eluting Stent : Case on MDCT Calcium-Scoring Implementation Patient (약물용출 스텐트를 이용한 관상동맥중재술 후 재협착의 독립적 예측인자에 관한 연구 : MDCT calcium-scoring 시행 환자 대상으로)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo;Jang, Young-Ill
    • Journal of radiological science and technology
    • /
    • 제33권1호
    • /
    • pp.37-44
    • /
    • 2010
  • We sought to confirm an independent factor about in-stent restenosis (ISR) in the patients who underwent drug-eluting stent (DES) and know a possibility as a predictor of measured coronary artery calcium score by MDCT. A total of 178 patients (159 men, $61.7{\pm}10.0$ years of age) with 190 coronary artery lesions were included in this study out of 1,131 patients who underwent percutaneous coronary intervention (PCI) with DES implantation for significant stenosis on MDCT at Chonnam National University Hospital between May 2006 and May 2009. All lesions were divided into two groups with the presence of ISR : group I (re ISR, N = 57) and group II (no ISR, N = 133). Compared to group II, group I was more likely to be older ($65.8{\pm}9.0$ vs. $60.2{\pm}9.9$ years, p = 0.0001), diabetic (21.8% vs. 52.6%, p = 0.0001), have old myocardial infarction (8.8% vs. 2.3%, p = 0.040), left main stem disease (5.3% vs. 0.8%, p = 0.047), and smaller stent size ($3.1{\pm}0.3\;mm$ vs. $3.3{\pm}0.4\;mm$, p = 0.004). Group II was more likely to be smokers (19.3% vs. 42.1%, p = 0.003), have dyslipidemia (8.8% vs. 23.3%, p = 0.019). Left ventricular ejection fraction, lesion complexity, and stent length were not different between the two groups. Total CAC score was $389.3{\pm}458.3$ in group I and $371.2{\pm}500.8$ in group II (p = 0.185). No statistical difference was observed between the groups in CAC score in the culprit vessel, left main stem, left anterior descending artery, left circumflex artery, and right coronary artery. On multivariate logistic regression analysis, left main stem disease (OR = 168.0, 95% CI = 7.83-3,604.3, p = 0.001), male sex (OR = 36.5, 95% CI = 5.89-2,226.9, p = 0.0001), and the presence of diabetes (OR = 2.62, 95% CI = 1.071-6.450, p = 0.035) were independent predictors of ISR after DES implantation. In patients who underwent DES implantation for significant coronary stenosis on MDCT, ISR was associated with left main stem disease, male sex, and the presence of diabetes. However, CAC score by MDCT was not a predictor of ISR in this study population.

A Study on the Availability of the On-Board Imager(OBI) and Cone-Beam CT(CBCT) in the Verification of Patient Set-up (온보드 영상장치(On-Board Imager) 및 콘빔CT(CBCT)를 이용한 환자 자세 검증의 유용성에 대한 연구)

  • Bak, Jino;Park, Sung-Ho;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • 제26권2호
    • /
    • pp.118-125
    • /
    • 2008
  • Purpose: On-line image guided radiation therapy(on-line IGRT) and(kV X-ray images or cone beam CT images) were obtained by an on-board imager(OBI) and cone beam CT(CBCT), respectively. The images were then compared with simulated images to evaluate the patient's setup and correct for deviations. The setup deviations between the simulated images(kV or CBCT images), were computed from 2D/2D match or 3D/3D match programs, respectively. We then investigated the correctness of the calculated deviations. Materials and Methods: After the simulation and treatment planning for the RANDO phantom, the phantom was positioned on the treatment table. The phantom setup process was performed with side wall lasers which standardized treatment setup of the phantom with the simulated images, after the establishment of tolerance limits for laser line thickness. After a known translation or rotation angle was applied to the phantom, the kV X-ray images and CBCT images were obtained. Next, 2D/2D match and 3D/3D match with simulation CT images were taken. Lastly, the results were analyzed for accuracy of positional correction. Results: In the case of the 2D/2D match using kV X-ray and simulation images, a setup correction within $0.06^{\circ}$ for rotation only, 1.8 mm for translation only, and 2.1 mm and $0.3^{\circ}$ for both rotation and translation, respectively, was possible. As for the 3D/3D match using CBCT images, a correction within $0.03^{\circ}$ for rotation only, 0.16 mm for translation only, and 1.5 mm for translation and $0.0^{\circ}$ for rotation, respectively, was possible. Conclusion: The use of OBI or CBCT for the on-line IGRT provides the ability to exactly reproduce the simulated images in the setup of a patient in the treatment room. The fast detection and correction of a patient's positional error is possible in two dimensions via kV X-ray images from OBI and in three dimensions via CBCT with a higher accuracy. Consequently, the on-line IGRT represents a promising and reliable treatment procedure.

Clinical Significance of Reverse Redistribution on Tc-99m MIBI and T1-201 Myocardial Perfusion SPECT Images (Tc-99m MIBI와 T1-201 심근 SPECT에서 역재분포의 임상적 의의)

  • Song, Ho-Cheon;Bom, Hee-Seung;Kim, Ji-Yeul;Jeong, Myung-Ho;Gill, Kwang-Chae;Park, Joo-Hyung;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • 제30권1호
    • /
    • pp.95-103
    • /
    • 1996
  • Reverse redistribution(RRD) refers to a perfusion defect that develops or becomes more evident on rest imaging compared with the stress imaging. This phenomenon was not uncommonly noted on myocardial perfusion single photon emission computed tomography (SPECT). However, the clinical significance and pathophysiological mechanism of RRD were unclear. The aim of this study was to evaluate the incidence and clinical significance of RRD on either dipyridamole T1-201 or Tc-99m MIBI myocardial perfusion SPECT. RRD was defined as ${\geq}10%$ decrease in relative T1-201 and Tc-99m MIBI uptakes on rest images compared to the stress images or as an appearance of new perfusion defects on rest images. It was observed in both T1-201 (44/463, 9.5%) and Tc-99m MIBI (124/999, 12.4%) myocardial SPECTs similarly, with an overall incidence of 11.5%(168/1462). Many apparent)y unrelated disease groups showed the finding: post-revascularization(53.9%), coronary artery disease(24.6%), myocardial infarction(12.3%), and those with normal coro-nary arteries (9.2%). Clinical and angiographic characteristics of 65 consecutive patients who underwent coronary arteriography in 168 patients who had RRD on myocardial perfusion SPECT were reviewed. Tc-99m MIBI was used in 44 patients, and T1-201 was used in 21 patients. Of the 81 myocardial segments analyzed which showed RRD, 32 segments(39.5%) were in septum, 24(29.5%) in inferior wallL, 12(14.8%) in anterior wall, 7(8.7%) in apex and 6(7.4%) in lateral wall. There was no clear association between RRD and coronary arterial stenosis or Presence of collateral circulations. Ventriculographical wall motion was evaluated in 27 regions with RRD; it was normal in 12 regions, hypokinetic in 12 regions and dyskinetic in 3 regions. In 14 of 21 patients who showed RRD on T1-201 myocardial SPECT, T1-201 reinjection was performed immediately after the 3-4 hour redistribution studies. Ten of 14 (71.4%) showed enhanced T1-201 activity(${\geq}10%$ increased) after reinjection. We conclude that RRD is not related to mode of stress or radiopharmaceuticals. RRD might represent many inhomogeneous pathophysiological processes.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제12권3호
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

The Efficacy of the Change in Belly Board Aperture Location by the Addition of Bladder Compression Device for Radiotherapy of Rectal Cancer (직장암 환자의 골반 방사선치료에서 벨리보드 하위 경계 위치 변화의 영향)

  • Yoon, Hong-In;Chung, Yoon-Sun;Kim, Joo-Ho;Park, Hyo-Kuk;Lee, Sang-Kyu;Kim, Young-Suk;Choi, Yun-Seon;Kim, Mi-Sun;Lee, Ha-Yoon;Chang, Jee-Suk;Cha, Hye-Jung;Seong, Jin-Sil;Keum, Ki-Chang;Koom, Woong-Sub
    • Radiation Oncology Journal
    • /
    • 제28권4호
    • /
    • pp.231-237
    • /
    • 2010
  • Purpose: We investigated the effect of location changes in the inferior border of the belly board (BB) aperture by adding a bladder compression device (BCD). Materials and Methods: We respectively reviewed data from 10 rectal cancer patients with a median age 64 years (range, 45~75) and who underwent computed tomography (CT) simulation with the use of BB to receive pelvic radiotherapy between May and September 2010. A CT simulation was again performed with the addition of BCD since small bowel (SB) within the irradiated volume limited boost irradiation of 5.4 Gy using the cone down technique after 45 Gy. The addition of BCD made the inferior border of BB move from symphysis pubis to the lumbosacral junction (LSJ). Results: Following the addition of BCD, the irradiated volumes of SB and the abdominopelvic cavity (APC) significantly decreased ($174.3{\pm}89.5mL$ vs. $373.3{\pm}145.0mL$, p=0.001, $1282.6{\pm}218.7mL$ vs. $1,571.9{\pm}158mL$, p<0.001, respectively). Bladder volume within the treated volume increased with BCD ($222.9{\pm}117.9mL$ vs. $153.7{\pm}95.5mL$, p<0.001). The ratio of irradiated bladder volume to APC volume with BCD ($33.5{\pm}14.7%$) increased considerably compared to patients without a BCD ($27.5{\pm}13.1%$) (p<0.001), and the ratio of irradiated SB to APC volume decreased significantly with BCD ($13.9{\pm}7.6%$ vs. $24.2{\pm}10.2%$, p<0.001). The ratios of the irradiated SB volume and irradiated bladder volume to APC volume negatively correlated (p=0.001). Conclusion: This study demonstrated that the addition of BCD, which made the inferior border of BB move up to the LSJ, increased the ratio of the bladder to APC volume and as a result, decreased the irradiated volume of SB.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제26권1호
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.