The Korean Journal of Nuclear Medicine Technology (핵의학기술)
- Volume 14 Issue 1
- /
- Pages.83-89
- /
- 2010
- /
- 1229-9901(pISSN)
- /
- 2982-8406(eISSN)
Utility of Wide Beam Reconstruction in Whole Body Bone Scan
전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성
- Kim, Jung-Yul (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System) ;
- Kang, Chung-Koo (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System) ;
- Park, Min-Soo (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System) ;
- Park, Hoon-Hee (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System) ;
- Lim, Han-Sang (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System) ;
- Kim, Jae-Sam (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System) ;
- Lee, Chang-Ho (Department of Nuclear Medicine, Severance hospital, Yonsei University Health System)
- 김정열 (연세의료원 세브란스병원 핵의학과) ;
- 강청구 (연세의료원 세브란스병원 핵의학과) ;
- 박민수 (연세의료원 세브란스병원 핵의학과) ;
- 박훈희 (연세의료원 세브란스병원 핵의학과) ;
- 임한상 (연세의료원 세브란스병원 핵의학과) ;
- 김재삼 (연세의료원 세브란스병원 핵의학과) ;
- 이창호 (연세의료원 세브란스병원 핵의학과)
- Received : 2009.12.01
- Accepted : 2009.12.15
- Published : 2010.06.05
Abstract
Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of
UltraSPECT사의 Wide Beam Reconstruction (WBR)은 노이즈(Noise)와 조준기의 광속 확산 함수 효과(Beam spread function effect)를 제거하고 환자와의 거리를 자동적으로 보상하여 높은 해상도와 대조도를 제공할 수 있어 영상 획득 시간을 짧게 할 수 있고 상당한 영상 질 향상에 도움을 준다고 보고되고 있다. 이에 본 연구에서는 핵의학 분야에서 가장 흔히 이용되는 전신 뼈 스캔에 대해 WBR의 임상적 적용에 대한 유용성을 알아보고자 한다. XpressBone (WBR)의 성능 실험을 위하여 NEMA에서 제공하는 방법에 의하여 선원(Line source)과 SPECT Phantom을 이용하여 공간 분해능을 측정 분석하였다. 실험방법은 선원의 총 계수치를 200 kcps에서 300 kcps로 변화시켜 측정하였으며, SPECT Phantom은 매트릭스 크기를 변화시켜 측정하여 공간분해능에 대한 분석을 하였다. 또한 2009년 1월부터 2009년 9월까지 본원을 내원하여 뼈 스캔을 시행 받은 환자 40명을 두 군으로 나누어 임상 연구를 시행하였다. 1군은