• 제목/요약/키워드: Compression-Only

검색결과 937건 처리시간 0.024초

가슴압박만 하는 심폐소생술과 30 : 2 표준 심폐소생술 방법에 의한 가슴압박 질의 비교 (Comparison of chest compression quality between compression-only CPR and 30 : 2 conventional CPR)

  • 민문기;류지호
    • 한국응급구조학회지
    • /
    • 제19권3호
    • /
    • pp.139-148
    • /
    • 2015
  • Purpose: This study aimed to compare the chest compression quality between compression-only cardiopulmonary resuscitation (CPR) and conventional CPR. Methods: This study involved 123 participants randomly assigned to either the chest compression-only CPR training and conventional CPR training. After training for 120 min, the participants performed CPR for 4 min and the CPR quality was evaluated. The primary outcome was evaluated as the mean compression depth, and the secondary outcome was calculated as the proportion of chest compressions with an appropriate depth among the total chest compressions. Results: The mean compression depth was more deeper in conventional CPR than in compression-only CPR (57mm vs. 53mm, p <.001). The proportion of appropriate chest compression depth was also more higher in conventional CPR (98.8% vs. 68.6%, p <.001). As compared with every minute over time for a total of 4 min, the mean compression depth and the proportion of appropriate chest compression depth were deeper and higher after 1 min in conventional CPR than in compression-only CPR. Conclusion: The results suggested that conventional CPR is a better method than compression-only CPR in terms of chest compression quality.

철근 압축이음에서 지압강도와 부착강도의 실험적 평가 (Experimental Evaluation of Bearing and Bond Strengths in Compression Splices)

  • 천성철;이성호
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.129-136
    • /
    • 2012
  • 철근 압축이음은 초고층 건축물의 수직 부재에서 거의 모든 층에서 발생되므로, 압축이음 거동에 대한 명확한 이해는 합리적인 이음부 설계에 필수 요소가 된다. 이 연구에서는 압축을 받는 철근이음의 인자별 특성을 분석하기 위해, 부착 또는 지압만 존재하는 압축이음 실험을 수행하였다. 실험 결과 부착과 지압이 함께 존재하는 일반이음에서는 부착과 지압의 상호 간섭으로 각각의 고유 강도가 100% 발현되지는 않았다. 특히 지압은 국부적인 영역에서 발현되므로 중첩으로 인한 감소량이 부착에 비해 컸다. 부착과 지압이 함께 존재하는 일반이음은 부착이음과 지압이음에 비해 동일하중에서 콘크리트와 철근의 상대변위를 줄일 수 있다. 이음 파괴는 콘크리트와 철근 사이의 과도한 상대변위로 인해 발생되므로 일반이음의 강도가 부착이음과 지압이음에 비해 항상 높아진다. 따라서 부착 또는 지압을 제거함으로써 압축이음강도를 향상시킬 수는 없다. 또한 부착이음에서 순수 부착강도는 인장이음의 부착강도와 거의 유사하게 나타났으므로, 압축이음강도가 인장이음강도보다 큰 것은 지압의 영향임을 알 수 있다.

새로운 압축 방식을 이용한 인과관계 순서화 알고리즘 (A causal ordering algorithm using a new compression method)

  • 권봉경;정광수
    • 한국통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.1127-1136
    • /
    • 1997
  • A vector timestamp is used to satisfy message ordering in a group communications. In this paper, we propose a new vector timestamp compression method which is applicable to a single process group environment where one process belongs to only one precess group. An existing compression method compares the fields of the previously sent vector timestamp with thouse of the currently updated vector timestamp, then sends only the modified fields of the vector timestamp. Unlike the previous one, a proposed compression method performs individual compression for each process using the locally maintained vector timestamp information on other processes. Also, we logicallyproved the causal ordering algorithm using the new compression method and compared the performance of the proposed method with one of the previous compression method by computer simulation. Using the proposed compression method, the message overhead required for causal ordering can be reduced.

  • PDF

신경망 기반 블록 단위 위상 홀로그램 이미지 압축 (Block-based Learned Image Compression for Phase Holograms)

  • 최승미;박수용;반현민;차준영;김휘용
    • 방송공학회논문지
    • /
    • 제28권1호
    • /
    • pp.42-54
    • /
    • 2023
  • 방대한 홀로그램 데이터를 디지털 형식으로 압축하는 것은 중요한 문제이다. 특히, 상용화를 위해 위상 전용 홀로그램의 압축에 관한 연구가 주목된다. 자연 영상에 최적화된 기존 표준 압축 기술은 위상 신호를 압축하는데 적합하지 않으며, 위상 신호에 대해 최적화 가능한 신경망 기반 압축 기술은 좋은 성능을 기대할 수 있으나 고해상도 홀로그램 데이터를 학습하는 데 메모리 문제가 존재한다. 본 논문에서는 메모리 문제를 해결할 수 있는 학습 가능한 신경망 기반의 블록 단위 압축 기술을 위상 전용 홀로그램에 적용해봄으로써 블록 기반이라는 동일 조건 내에서도 제안 방식이 표준 코덱보다 상당한 성능향상을 보일 수 있음을 밝혔다. 신경망 기반의 블록 단위 압축은 기존 코덱과의 호환성을 제공할 수 있으며, 메모리 문제를 해결하는 동시에 위상 전용 홀로그램 압축에 대해 월등히 좋은 성능을 보일 수 있다.

간세포암 환자에서 ABCHES와 복부압박장비의 적용한 호흡동조방사선 치료의 유용성 비교 (Comparison with ABCHES and Abdomen Compression Device in Respirational Radiation Therapy on Patients in Hepatocellular Carcinoma)

  • 조윤진;변상준;김영재
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.395-402
    • /
    • 2012
  • 호흡조절 방사선치료는 호흡이나 장기의 움직임을 극복하기 위하여 환자의 호흡주기를 획득하여 종양조직에 처방선량을 부여하며 동시에 주위 정상조직에는 적은 방사선량을 부여하는 방법이다. ABCHES를 이용한 호흡조절 방사선 치료는 호흡을 얕은 호흡으로 유도하며 종양조직의 움직임을 최소화 하는데 도움을 줄 수 있는 부속 장비이다. 한편 복부 압박 기구는 환자의 복부에 압박을 실시함으로 호흡에 제한을 두는 치료보조용 기구이다. 본 논문에서는 ABCHES를 단독으로 사용한 것과 ABCHES와 복부압박 장비를 이용하여 간세포암 환자의 종양의 움직임을 정량적으로 분석하고 그에 해당하는 치료효과를 선량체적곡선으로 분석하려 하였다. ABCHES를 사용한 경우와 ABCHES와 복부압박기구를 동시에 사용한 경우를 비교해본 결과 상하 방향과 앞뒤 방향 그리고 좌우 향으로 각각 평균 1.0 mm, 0.2 mm, 0.2 mm 정도로 그 움직임을 제한 할 수 있음을 확인할 수 있었다. 체적 감소율 또한 ABCHES를 사용한 경우 HPTV와 LPTV가 체적의 변화율을 $16{\pm}2%$ 정도로 줄일 수 있었고, LPTV의 경우 $15.8{\pm}0.8%$의 체적을 제어할 수 있었다. 선량체적 곡선을 분석한 경우 ABCHES만을 사용한 경우보다 ABCHES와 복부압박 기구를 동시에 사용한 경우가 종양조직에는 처방선량에 가까운 선량값을 보였으며 정상조직인 동측 폐, 콩팥, 정상 간조직에는 보다 적은 선량이 부여된 것을 확인 할 수 있었다. 본 논문에 결과 ABCHES를 단독으로 사용하는 것보다 복부압박기구와 ABCHES를 동시에 사용한 경우가 종양 및 정상조직에 부여된 선량 기준에 적합하다고 판명 되었고, 향후 ABCHES와 복부압박 기구에 대한 제한점 즉, 복부의 압박강도에 따른 환자의 불편감, 호흡주기가 정확하지 않은 환자들에게 적용하여야 하는 방법 등이 추후에 논의 되어야 할 것으로 사료된다.

사출 및 사출/압축 성형품 내에서의 복굴절 구조 변화에 관한 연구 (A Study on The Change of Birefringence Structure in Injection and Injection/compression Molded Products)

  • 민인기;이경범;윤경환
    • 소성∙가공
    • /
    • 제19권5호
    • /
    • pp.296-304
    • /
    • 2010
  • It is still needed to study the effect of process conditions on the final properties of injection-molded parts for producing precision optical products. Especially, the optical anisotropy, i.e., birefringence, is a significant factor to affect the function of many optical components. In the present study we have focused on the effect of holding and compression processes on the birefringence remaining in the transparent disc by examining the gap-wise distribution of birefringence and extinction angle. As a result, two extra birefringence and extinction peaks near the center in thickness direction showed the effect of holding pressure, which came from the flow in packing stage. However, more uniform birefringence distribution than injection-only cases could be found in injection/compression cases. Depends on the process condition even the flow reversal could be found from the distribution of extinction angle. Finally, graphical representation of optical indicatrix was added for better understanding the final structure of injection-only and injection/compression cases.

심폐소생술 시행 위치변화에 따른 흉부압박의 질 비교 (Comparison of Qualities of Chest Compression according to Changes of Position in Cardiopulmonary Resuscitation Performance)

  • 권혜란;박대성
    • 한국응급구조학회지
    • /
    • 제15권1호
    • /
    • pp.37-46
    • /
    • 2011
  • Purpose : This study is equivalence experiment performed to test practice effects between experimental group from both left and right direction of mannequin and control group having practice from only right direction in cardiopulmonary resuscitation education. Methods : Subject of the research were total 71 elementary and middle school teachers in J province who had not experience to have cardiopulmonary resuscitation. They were divided into experimental group of 35 participants who practiced cardiopulmonary resuscitation from both right and left direction of mannequin on Dec. 27, 2009 and control group of 36 participants who performed cardiopulmonary resuscitation from only right direction of mannequin on Dec. 28, 2009. Collected data were analyzed by SPSS/PC+(version 14.0). Results : 1. There was no statistically significant difference by sex among general characteristics of the subjects. 2. According to the quality of chest compression performed from the right direction of mannequin, experimental group showed better results in proper depth (time), insufficient depth (time), too lowered compression position (time) and inexact position (time) than control group(p<.05). In the quality of chest compression from the left side of mannequin, experimental group performed better results in proper depth (time), insufficient depth (time), inexact compression position (time) and mean chest compression depth(mm) than control group(p<.05) and also in more left-centered compression position (time) than control group(p<.001). 3. The quality of chest compression by experimental group, the right side of mannequin was superior in proper depth (time) to the left side of mannequin (p<.001) and showed better results in insufficient depth (time) and chest compression/recoil rate (p<.05). According to the quality of chest compression by control group, the right side of mannequin showed superior results in proper depth (time), insufficient depth (time), too left-centered compression position (time) and mean chest compression depth (mm) (p<.05) to the left side of mannequin. Conclusion : The group having practice from both right and left sides of mannequin was superior in the quality of chest compression to the group having practice from only right side of mannequin. How to practice cardiopulmonary resuscitation from both right and left sides of mannequin can be recommended and practice from left side of mannequin is also useful.

저압축 고팽창 기관의 기술과 개발동향 (trends in Techical a development of Miller Cycle for Gasdline Engine)

  • 정찬문
    • 기술사
    • /
    • 제34권2호
    • /
    • pp.31-36
    • /
    • 2001
  • The Otto Cycle of conventional gasoline engine has no difference between compression ratio and expension ratio. because of the same length of 4 strokes : Intake, compression, expension, exhaust. On the other hand, miller cycle engine achieves both low-compression ratio and high-compression ratio by shortening the length of compression stroke among 4 strokes. Therefore miller cycle engine is essential for lessening knocking and improving heat efficiency. This paper Is designed to discribe not only principle and the development trend of miller cycle engine but also the control system and the technical characteristics of it.

  • PDF

영상 이해를 통한 지능형 영상압축 시스템 (An Intelligence Image Compression System through Image Understanding)

  • Kim, Jin-Hyung
    • 대한전자공학회논문지
    • /
    • 제24권6호
    • /
    • pp.961-968
    • /
    • 1987
  • This paper describes an intelligent image compression system called AIIC which is capable of adjusting image compression ratios ranging from 1:1 to 12,000:1 depending on available bandwidth. This system utilizes not only conventional image compression algorithms but also intelligent techniques through understanding image contents to achieve ultra-high compression ratios. This system was simulated on a micro-computer network.

  • PDF

SSI해석을 통한 압축전담 교량 내진보강공법 거동 특성 연구 (Behavior Characteristics of Compression-Only Bridge Seismic Reinforcement Method Using SSI Analysis)

  • 장유식;윤원섭;유광호
    • 한국산업융합학회 논문집
    • /
    • 제25권6_3호
    • /
    • pp.1231-1238
    • /
    • 2022
  • In this study, the reinforcement effect of the compression-only bridge seismic reinforcement method, which is mainly applied to old bridges, was studied through SSI analysis. As the analysis conditions, acceleration magnitudes of 0.1g, 0.15g, and 0.2 g were applied, and long-period and short-period seismic waves were applied. As a result of the analysis according to the assumed ground characteristics and structure size, the horizontal displacement at the reinforced section was reduced by about 9%, and the long-period seismic wave had a 95% larger displacement than the short-period seismic wave. In addition, an increase in acceleration of 0.1g resulted in a displacement of about 50%, and a large increase in displacement was observed in long-period seismic waves. As a result of the analysis, in the case of the compression-only bridge seismic reinforcement method, there was a reinforcing effect, so the field applicability was excellent.