Abstract
4D-Radiation Therapy is the optimal treatment to track moving organs(tumor) and give the appropriate prescription dose to tumor and low radiation dose to normal tissue surrounding tumor volume. The ABCHES is a 4DRT devices maintaining shallow breathing to patients. It allows the tumor's movement was minimize. Meanwhile, Abdominal compression device is limited the breath compressing abdomen on patients. In this paper we will quantitative analysis the movement of tumor on only ABCHES versus ABCHES with Abdomal compression device and Analysis tumor dose and normal tissue's dose by Dose Volume Histogram on two parts. The result of Comparision ABCHES and ABCHES with Abdominal compression device, SI(Superior-Inferior) direction, AP(Anterior-Posterior) direction and LR(Left-Right) direction was limited 1.0 mm, 0.2 mm, 0.2 mm(average). and also reduction rate of voluume in HPTV was $16{\pm}2%$, and LPTV was $15.8{\pm}0.8%$ under only using ABCHES and ABCHES with compression. The analysis dose volume histogram was more radiation dose in ABCHES and abdominal compression device than only using ABCHES, and less normal tissue-ipsilateral lung, whole lung, kidney-dose in ABCHES and abdominal compression device than only using ABCHES. The overall analysis was ABCHES with abdominal compression better than only using ABCHES method. In hereafter it will be studies that limitation of ABCHES and abdomonal compression device. In other words, patient's discomfort on compression intensity, method of application on patient with inaccurate respiration cycle.
Keywords
4DRT; Liver cancer; ABCHES;
Citations & Related Records
연도 인용수 순위
  • Reference
1 ICRU, International Commission on Radiation Units and Measurements. Report 62: Prescribing, Recording and Reporting Photon Beam Therapy (Supplement to ICRU Report 50).1999
2 Jin JY, Ajlouni M, Chen Q, et al. Quantification of incidental dose to potential clinical target volume (CTV) under different stereotactic body radiation therapy (SBRT) techniques for non-small cell lung cancer-tumor motion and using internal target volume (ITV) could improve dose distribution in CTV. Radiother Oncol, Vol. 85, pp.267-276, 2007   DOI   ScienceOn
3 Van der Geld YG, van Triest B, Verbakel WF, et al. Evaluation of four-dimensional compute d tomography-based intensity-modulated and respiratory-gated radiotherapy techniques for pancreatic carcinoma. Int J Radiat Oncol Biol Phys, Vol. 72, No. 4, pp.1215-1220, 2008   DOI   ScienceOn
4 AAPM REPORT No.91 -The Management of Respiratory Motion in Radiation Oncology Report of AAPM Task Group76.
5 Ogata K, Hizawa K, Yoshida M, Kitamuro T, Akogi G, Kagawa K, et al. Hepatic Injury Following Irradiation- A Morphologic Study. Tokushima J Exp Med, Vol. 43, pp.240-251, 1963
6 이익재, 성진실, 심수정 등, 간세포암종의 방사선치료 시 발생하는 간독성에 대한 위험인자의 재고찰, 대한간학회, Vol. 12, No. 3, pp 420-428, 2006
7 Marks L. Dosimetric predictors of radiation-induced lung injury. Int J Radiat Oncol Biol Phys, Vol. 54, pp.313-316, 2002
8 International Commission on Radiation Units and Measurements(ICRU), "Prescribing, recording and reporting photon beam therapy," Report No. 50 (ICRU, Bethesda, MD, 1993).
9 조윤진, 전미진, 임정호 등, 호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdominal and Chest Motion Control Device의 유용성 평가, 대한방사선치료학회, 춘계학술대회 논문지, pp.15-16, 2012
10 Wouter W, Alejandar M, Willy K, et al.: Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial marker implanted in liver. Int. J.Radiat Oncol Biol Phys, Vol. 71, pp.907-915, 2008   DOI   ScienceOn
11 V. Y. Wong, S. Y. Tung, A. W. Ng, F. A. Li, and J.O.Leung,"Real-timemonitoring and control on deep inspiration breath-hold for lungcancer radiotherapy combination of ABC and external marker tracking," Med.Phys. pp.4673-4683, 2010
12 8. Vedam SS, Keall PJ, Kini VR, et al.: Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol, Vol. 48, pp.45-62, 2003   DOI   ScienceOn
13 Onimaru R, Shirato H, Fujino M, et al. The effect of tumor location and respiratory fuction on tumor movement estimated by real-time tracking radiotherapy (RTRT) system. Int J Radiat Oncol Biol Phys, Vol. 63, pp.164-169, 2005   DOI   ScienceOn
14 임상욱, 안승도, 박성호 등, 열전쌍마스크를 이용한 호흡모사팬톰 연구, 대한 방사선종양학회지, Vol 23, No 4, pp.217-222, 2005
15 이 석, 이상훈, 신동호 등, 동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선 치료 기술 개발, 대한방사선종양학회지, Vol. 22, No. 4, pp.316-324, 2004
16 한국중앙암등록본부: 국가암등록사업 연례보고서(2009년 암발생 현황). 보건복지부, pp.1-114, 2009
17 T Tarohda, M Ishiguro, K Hasegawa, et al.: The management of tumor motion in the stereotatic irradiation to lung cancer under the use of abches to control active breathing. Am Assoc Phys Med, Vol. 38, 2011
18 Lawrence TS, Robertson JM, Anscher MS, Jirtle RL, Ensminger WD, Fajardo LF. Hepatic toxicity resulting from cancer treatment. Int J Radiat Oncol Biol Phys, Vol. 31, pp.1237-1248, 1995   DOI   ScienceOn