• Title/Summary/Keyword: Composite

Search Result 22,080, Processing Time 0.049 seconds

Evaluation of friction of ceramic brackets in various bracket-wire combinations (브라켓 각도 변화에 따른 세라믹 브라켓의 마찰력 측정)

  • Cha, Jung-Yul;Kim, Kyung-Suk;Kim, Dong-Choon;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.36 no.2 s.115
    • /
    • pp.125-135
    • /
    • 2006
  • The purpose of this study was to measure and compare the level of frictional resistance generated from three currently used ceramic brackets; 1, Crystaline $V^{(R)}$, Tomy International Inc., Tokyo, Japan; 2, $Clarity^{(R)}$, 3M Unitek, Monrovia, CA, USA; 3, $Inspire^{(R)}$, Ormco, Orange, CA, USA; with composite resin brackets, Spirit, Ormco, Orange, CA, USA; and conventional stainless steel brackets, Kosaka, Tomy International Inc., Tokyo, Japan used as controls. In this experiment, the resistance to sliding was studied as a function of four angulations $(0^{\circ},\;5^{\circ},\;10^{\circ}\;and\;15^{\circ})$ using 2 different orthodontic wire alloys: stainless steel (stainless steel, SDS Ormco, Orange, CA, USA), and beta-titanium (TMA, SDS Ormco, Orange, CA, USA). After mounting the 22 mil brackets to the fixture and $.019{\times}.025$ wires ligated with elastic ligatures, the arch wires were slid through the brackets at 5mm/min in the dry state at $34^{\circ}C$. Silica-insert ceramic brackets generated a significantly lower frictional force than did other ceramic brackets, similar to that of stainless steel brackets. Beta-titanium archwires had higher frictional resistance than did stainless steel, and all the brackets showed higher static and kinetic frictional force as the angulation increased. When the angulation exceeded $5^{\circ}$, the active configuration emerged and frictional force quickly increased by 2.5 to 4.5-fold. The order of frictional force of the different wire-bracket couples transposed as the angle increased. The silica-insert ceramic bracket is a valuable alternative to conventional stainless steel brackets for patients with esthetic demands.

Effect of Heat-Moisture Treatment of Domestic Rice Flours Containing Different Amylose Contents on Rice Noodle Quality (아밀로오스 함량이 다른 국내산 쌀가루의 수분-열처리가 쌀국수 품질에 미치는 영향)

  • Seo, Hye-In;Ryu, Bog-Mi;Kim, Chang-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.11
    • /
    • pp.1597-1603
    • /
    • 2011
  • The influence of heat-moisture treatment (HMT) and substitution of rice flour containing different amylose contents on the quality characteristics of rice noodles was investigated. HMT was applied to rice flours with 21% moisture content at 100 and 105$^{\circ}C$ for 30 min. Three rice cultivars were used, including high amylose of Goami (GM) and intermediate amylose of Choochung (CC) as domestic rice flours and imported rice of Taeguk (TG) as a control. HMT and substitution of rice flour with different amylose contents affected the cooking and texture quality of rice noodles. When rice noodles were made of intermediate amylose rice flour with HMT, cooking properties improved with decreased cooking loss and cooking water turbidity and thus were closer to those of control. Especially, the hardness, adhesiveness, tensile strength, and darkness of rice noodles notably increased when HMT rice flour was used. Based on the results of quantitative descriptive analysis for selected rice noodles, the noodles made of HMT CC at 105$^{\circ}C$ (CC105) had high scores for resilience and adhesiveness and low scores for hardness compared with imported commercial rice noodles and other experimental noodles such as TG, HMT GM100, TG+CC, and TG+CC105. In conclusion, rice noodles were made of composite flours containing high amylose and intermediate amylose contents or HMT intermediate amylose content rice flour.

Optimization of Microwave Extraction Conditions for Antioxidant Phenolic Compounds from Ligustrum lucidum Aiton Using Response Surface Methodology (반응표면분석법을 이용한 여정자의 페놀계 항산화 성분에 대한 마이크로웨이브 추출조건 최적화)

  • Yun, Sat-Byul;Lee, Yuri;Lee, Nam Keun;Jeong, Eung-Jeong;Jeong, Yong-Seob
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.4
    • /
    • pp.570-576
    • /
    • 2014
  • Response surface methodology (RSM) was applied to optimize the microwave-assisted extraction (MAE) conditions for electron-donating ability, total phenol content, and total flavonoid content of Ligustrum lucidum Aiton. Ligustrum lucidum Aiton from different regions was tested, and Ligustrum lucidum Aiton from Haenam was chosen due to its higher total phenolic content, total flavonoid content, DPPH radical scavenging activity and ABTS radical scavenging activity compared to the other samples. Central composite design was used to optimize extraction of Ligustrum lucidum Aiton from Haenam as well as determine the effects of extraction temperature ($X_1$) and extraction time ($X_2$) on dependent variables ($Y_n$). Determination coefficients ($R^2$) of the regression equations for dependent variables ranged from 0.8858 to 0.9517. The optimum points were $131.68^{\circ}C$ for extraction temperature and 5.49 min for extraction time. Predicted values of the optimized conditions were acceptable when compared to experimental values.

ESR-Spin Trapping Detection of Radical Center Formed on the Reaction of Metmyoglobin with Hydrogen Peroxide

  • Jeong, Sang-Hyeon;Hong, Sun-Joo
    • BMB Reports
    • /
    • v.28 no.4
    • /
    • pp.293-300
    • /
    • 1995
  • The radical centers detected in the reaction of metmyoglobin (MetMb) with hydrogen peroxide ($H_2O_2$) have been studied by using a spin trapping technique. A broad 5-line asymmetric electron spin resonance (ESR) spectrum, with $2A_{max}=4.07\;mT$ and $2A_{min}=2.97\;mT$, obtained after incubation of MetMb with $H_2O_2$ in the presence of a spin trap, 5,5-dimethyl pyrroline-N-oxide (DMPO) was gradually weakened with time and disappeared completely by 6 min after addition of guanidine-HCl (14 M). When a higher concentration (6 M) of the agent was added, the signal disappeared within 40 see and the DMPO/OH signal appeared immediately. Then, a new 8-line signal with similar intensities grew gradually and was fixed by 45 min, coexisting with the DMPO/OH signal. This new signal was found to be composite, consisting of two different radical species. One of the 6-line signals, with $a_N$ 1.49 mT and $a_H$ 0.988 mT, was assigned to the DMPO/phenoxyl radical adduct. The second 6-line signal with $a_N$ 1.55 mT and $a_H$ 2.22 mT was assigned to carbon-centered radical adduct. When 3,3,5,5-tetramethylpyrrolin-N-oxide (TMPO), was employed in the place of DMPO, another broad asymmetric 5-line signal was detected with $2A_{max}=3.99\;mT$ and $2A_{min}=3.04\;mT$, which is virtually identical to that obtained from the DMPO system The shape of the spectrum of the TMPO adduct changed drastically, with lapse of time resulting in a broad singlet after 40 min. The broad singlet was assigned to the porphyrin radical adduct. Incubation of globin with Fenton reagent in the presence of DMPO initially gave a DMPO/OH signal. Then, a new 12-line signal began to grow after one minute and fixed after 15 min. coexisting with the DMPO/OH signal, This 12-line signal was assigned to DMPO/phenoxyl with $a_N$ 1.47 mT, $a_{{\beta}H}$ 0.99 mT and $a_{{\gamma}H}$ 0.13 mT. A minor concentration of carbon-centered radical adduct was also detected. This radical composition is identical to that of guanidine HCl treated MetMb/DMPO/$H_2O_2$ system, indicating that the radical producing conditions are somehow common in both systems. Heme iron can be released by excess $H_2O_2$ in the MetMb/$H_2O_2$ system, providing for Fenton reagent. When MetMb was pretreated with tyrosine blocking agent, $KI_3$ the broad 5.line MetMb-derived signal was not detected in the MetMb/DMPO/$H_2O_2$ system, whereas no such effect was detected on such system of Hb in which the radical center was assigned to cysteine residue not tyrosine, indicating that tyrosine residue is a main radical center produced in the MetMb/$H_2O_2$ system Thus, the present data strongly support the previous indication that the apomyoglobin-derived radical center formed in the reaction of MetMb with $H_2O_2$ is a tyrosine residue.

  • PDF

Effects of Several Soil Composites and Fertilizers to Plant Growing on the Artificial Planting Ground (인공식재지반의 토양배합 및 비료종류에 따른 초본식물의 생육효과)

  • Lee, Eun-Yeob;Moon, Seok-Ki
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.2 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • To find pertinent soil type and maintenance method for artificial planting ground, the effects of soil compositions{sandy loam(S), vermiculite(V), sandy loam+vermiculite+sand(SVS), sandy loam+ carbonized rice husk+sand(SCS), sandy loam+humus sawdust+sand(SHS)}, and fertilizers (organic, chemical) on plant(kentuckyblue grass) growth were measured and compared from the field experiment. The results are summarized as follows 1. the highest germination rate is found from "vermiculite(V)" and the lowest from "sandy loam(S)" among tested 5 soil compositions. 2. "sandy loam+vermiculite+sand(SVS)" composition shows the highest plant height growth effect (5cm growth during tested 3 months) comparing to other 4 compositions. 3. "sandy loam+vermiculite+sand(SYS)" composition shows the highest ground covering rate after first two months, but it concede its order to "sandy loam+humus sawdust+sand(SHS)" composition after next one month growing. 4. the effects of fertilizers are follows 1) Among the blocks where no fertilizer was tried, the predominant height growth was obvious in "sandy loam+carbonized rice husk+sand(SCS)" and "sandy loam+humus sawdust+sand(SHS)" composition. 2) Among the blocks where chemical fertilizer was tried, relatively positive results were found from "vermiculite(V)" and "sandy loam+vermiculite+sand(SYS)" blocks on germination and growth rate. But on the ground coverage ratio, the effect of "sandy loam+carbonized rice husk+sand(SCS)" composite precede that of those 2 composites. 3) Among the blocks where organic fertilizer was tried, "sandy loam+humus sawdust+sand(SHS)" and "vermiculite(V)" blocks show relatively high ground coverage rate, growth rate than others. 4) When compositional differences were not considered, the block where organic fertilizer was tried shows most positive effects on all 3 measurements-germination ratio, height growth and ground covering.

  • PDF

Composition Ratio Analysis of Transesterification Products of Olive Oil by Using Thin Layer Chromatography and Their Applicability to Cosmetics (올리브 오일의 에스터 교환반응 생성물의 TLC를 이용한 조성비 분석 및 화장품에의 응용가능성 평가)

  • Park, So Hyun;Shin, Hyuk Soo;Kim, A Rang;Jeong, Hyo Jin;Xuan, Song Hua;Hong, In Kee;Lee, Dae Bong;Park, Soo Nam
    • Applied Chemistry for Engineering
    • /
    • v.29 no.3
    • /
    • pp.342-349
    • /
    • 2018
  • In this study, the physicochemical properties, emulsifying capacity, moisture content and cytotoxicity of the composite material produced by transesterification reactions of the olive oil (olive oil esters) were investigated for cosmetic applications. Olive oil esters with short (S) and long (L) reaction times were studied. From the TLC-image analysis, composition ratios of the olive oil esters S were found to be 5.2, 24.1, 46.4, and 21.9% for mono-, di-, tri-glyceride, and fatty acid ethyl ester, respectively. Those of the olive oil esters L were 4.1, 24.7, 40.6, and 28.8% for mono-, di-, tri-glyceride, and fatty acid ethyl ester, respectively. The iodine value, acid value, saponification value, unsaponified matter, refractive index, and specific gravity were determined and purity tests were also carried out and normalized to establish standards and testing methods for using olive oil esters in cosmetics. To evaluate their emulsifying capacities, the O/W emulsion was prepared without surfactants and the formation of the emulsified particles were confirmed. After 5 days of applying the olive oil esters to human skin, the skin moisture retention was improved by 13.1% from the initial state. For the evaluation of toxicity on human skin cells, the olive oil esters showed 90% or more of the cell viability at $0.2-200{\mu}g/mL$. These results suggested that olive oil esters can be applied as natural/non-toxic ingredients to cosmetics industries.

Hypoglycemic and Hypolipidemic Effects of Jerusalem artichoke Composites in Streptozotocin induced Diabetic Rats (명월초, 여주 및 울금을 포함하는 돼지감자 복합물의 streptozotocin 유발 당뇨쥐에서 혈당강하 및 체내 지질개선에 미치는 영향)

  • Hu, Wen-Si;Lee, Soo-Jung;Pyo, Jae-Ho;Kim, Sung-Hee;Sung, Nak-Ju
    • Journal of Life Science
    • /
    • v.28 no.6
    • /
    • pp.671-680
    • /
    • 2018
  • Hypoglycemic and hypolipidemic effects of Jerusalem artichoke composites (JAP) with extracts of G. procumbens (12.5%), M. charantia (12.5%), and C. longa (12.5%) to H. tuberosus concentrate (JA, 50%) were evaluated in streptozotocin (STZ) induced diabetic rats. Rats were divided into seven groups: normal (Normal), diabetic control (Diabetic), group fed G. procumbens extract (0.5 g/kg bw, D-GPE), group fed JAP (0.5 g/kg bw, D-JAP1; 1.5 g/kg bw, D-JAP2), group fed JA (0.5 g/kg bw, D-JA), and group fed Metformin (0.2 g/kg bw, D-MET) as a positive control. The blood glucose levels over 4 weeks were significantly decreased in the D-JAP2 and D-MET groups compared to the other groups after 3 weeks. The serum insulin level was not significant among the groups fed an experimental diet, but the HOMA-IR value was significantly decreased compared to the diabetic control group. AST and ALT activities in the serum were lowest in D-JAP1. Total lipid and triglyceride contents in the serum decreased in the groups fed an experimental diet, and the HDL-C contents of D-GPE, D-JAP1, and D-JAP2 were significantly increased compared to the diabetic control group. Triglyceride contents in the liver tissue were significantly lower in the D-GPE, D-JAP1, and D-JAP2 groups, and hepatic TBARS content was significantly decreased in the D-JAP1 and D-JAP2 groups compared to the diabetic control group. Hepatic antioxidative enzyme levels, such as SOD, catalase, and GSH-Px, were significantly elevated in groups fed an experimental diet compared to the diabetic control group. Therefore, JAP may be more effective than JA in the human body due to its hypoglycemic and hypolipidemic activities.

Relationships between Nailfold Plexus Visibility, and Clinical Variables and Neuropsychological Functions in Schizophrenic Patients (정신분열병 환자에서 손톱 주름 총 시도(叢 視度) (Nailfold Plexus Visibility)와 임상양상, 신경심리 기능과의 관계)

  • Kang, Dae-Yeob;Jang, Hye-Ryeon
    • Korean Journal of Biological Psychiatry
    • /
    • v.9 no.1
    • /
    • pp.50-61
    • /
    • 2002
  • Objectives:High nailfold plexus visibility can reflect central nervous system defects as an etiologic factor of schizophrenia indirectly. Previous studies suggest that this visibility is particularly related to the negative symptoms of schizophrenia and frontal lobe deficiency. In this study, we examined the relationships between nailfold plexus visibility, and various clinical variables and neuropsychological functions in schizo-phrenic patients. Methods:Forty patients(21males, 19 females) satisfying the DSM-IV criteria for schizophrenia and thirty eight normal controls(20 males, 18 females) were measured for Plexus Visualization Score(PVS) by using the capillary microscopic examination. For the assessment of psychopathology, process-reactivity, premorbid adjustment, and neuropsychological functions, we used Positive and Negative Syndrome Scale(PANSS), Ullmann-Giovannoni Process-Reactive Questionnaire(PRQ), Phillips Premorbid Adjustment Scale(PAS), Korean Wechsler Adult Intelligence Scale(KWIS), Continuous Performance Test(CPT), Wisconsin Card Sort Test (WCST), and Word Fluency Test. We also collected data about clinical variables. Results:PVS was correlated with PANSS positive symptom score and composite score negatively. There were no correlations between PVS and PRQ score, PAS score and neuropsychological variables respectively. Conclusions:This study showed that nailfold plexus visibility was a characteristic feature in some schizophrenic patients, and that higher plexus visibility was associated with the negative symptoms of schizophrenia. There was no association between plexus visibility and neuropsychological functions.

  • PDF

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF

Evaluation of Effective and Organ Dose Using PCXMC Program in DUKE Phantom and Added Filter for Computed Radiography System (CR 환경에서의 흉부촬영 시 Duke Phantom과 부가여과를 이용한 유효선량 및 장기선량 평가)

  • Kang, Byung-Sam;Park, Min-Joo;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • By using a Chest Phantom(DUKE Phantom) focusing on dose reduction of diagnostic radiation field with the most use of artificial radiation, and attempt to reduce radiation dose studies technical radiation. Publisher of the main user of the X-ray Radiological technologists, Examine the effect of reducing the radiation dose to apply additional filtering of the X-ray generator. In order to understand the organ dose and effective dose by using the PC-Based Monte Carlo Program(PCXMC) Program, the patient receives, was carried out this research. In this experiment, by applying a complex filter using a copper and Al(aluminum,13) and filtered single of using only aluminum with the condition set, and measures the number of the disk of copper indicated by DUKE Phantom. The combination of the composite filtration and filtration of a single number of the disk of the copper is the same, with the PCXMC 2.0. Program looking combination of additional filtration fewest absorbed dose was calculated effective dose and organ dose. Although depends on the use mAs, The 80 kVp AP projection conditions, it is possible to reduce the effective amount of about 84 % from about 30 % to a maximum at least. The 120 kVp PA projection conditions, it is possible to reduce the effective amount of about 71 % from about 41 % to a maximum of at least. The organ dose, dose reduction rate was different in each organ, but it showed a decrease of dose rate of 30 % to up 100 % at least. Additional filtration was used on the imaging conditions throughout the study. There was no change in terms of video quality at low doses. It was found that using the DUKE Phantom and PCXMC 2.0 Program were suitable to calculate the effect of reducing the effective dose and organ dose.