• Title/Summary/Keyword: Co-cr alloy

검색결과 293건 처리시간 0.025초

고밀도화 공정에 의한 Fe-Co 계 밸브시트 합금의 조직변화와 열적 특성 (Thermal Properties and Microstructural Changes of Fe-Co System Valve Seat Alloy by High Densification Process)

  • 안인섭;박동규;안광복;신승목
    • 한국분말재료학회지
    • /
    • 제26권2호
    • /
    • pp.112-118
    • /
    • 2019
  • Infiltration is a popular technique used to produce valve seat rings and guides to create dense parts. In order to develop valve seat material with a good thermal conductivity and thermal expansion coefficient, Cu-infiltrated properties of sintered Fe-Co-M(M=Mo,Cr) alloy systems are studied. It is shown that the copper network that forms inside the steel alloy skeleton during infiltration enhances the thermal conductivity and thermal expansion coefficient of the steel alloy composite. The hard phase of the CoMoCr and the network precipitated FeCrC phase are distributed homogeneously as the infiltrated Cu phase increases. The increase in hardness of the alloy composite due to the increase of the Co, Ni, Cr, and Cu contents in Fe matrix by the infiltrated Cu amount increases. Using infiltration, the thermal conductivity and thermal expansion coefficient were increased to 29.5 W/mK and $15.9um/m^{\circ}C$, respectively, for tempered alloy composite.

Ni-MH 2차 전지용 Zr계 수소저장합금전극의 특성에 미치는 치환원소(Co, Cr, Fe)의 영향 (The effect of substitution elements(Co, Cr, Fe) on the properties of Zr-based hydrogen storage alloy electrode for Ni-MH secondary battery)

  • 최승준;정소이;서찬열;최전;박충년
    • 한국수소및신에너지학회논문집
    • /
    • 제10권3호
    • /
    • pp.185-189
    • /
    • 1999
  • Effects of alloy modification with the $Zr_{0.6}Ti_{0.4}V_{0.4}Ni_{1.2}Mn_{0.4}$ alloy for an electrode use have been investigated. For the alloy composition, a part of Mn was substituted by Co, Cr and Fe. The experimental results showed that Co accelerated activation of alloy, and Fe and Cr improved the discharge capacity. These results agree with P-C-T curves of each alloy. But substituting Fe for Mn showed the decrease of the discharge capacity when discharged at high rate (60mA, about 1C rate). Considering both the discharge capacity and the high rate discharge property, $Zr_{0.6}Ti_{0.4}V_{0.4}Ni_{1.2}Mn_{0.3}Cr_{0.1}$ alloy was found to be the best alloy among the alloys subjected to the test.

  • PDF

Sn 및 Cu를 첨가한 치과 주조용 Co-Cr-Mo계 합금제조 및 용해과정 분석 (Manufactures of dental casting Co-Cr-Mo based alloys in addition to Sn, Cu and analysis of infrared thermal image for melting process of its alloys)

  • 강후원;박영식;황인;이창호;허용;원용관
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.141-147
    • /
    • 2014
  • Purpose: Dental casting #Gr I (Co-25Cr-5Mo-3Sn-1Mn-1Si), #Gr II (Co-25Cr-5Mo-5Cu-1Mn -1Si) and #Gr III (Co-25Cr-5Mo-3Sn-5Cu-1Mn-1Si) master alloys of granule type were manufactured the same as manufacturing processes for dental casting Ni-Cr and Co-Cr-Mo based alloys of ingot type. These alloys were analyzed melting processes with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer. Methods: These alloys were manufactured such as; alloy design, the first master alloy manufatured using vacuum arc casting machine, melting metal setting in crucible, melting in VIM, pouring in the mold of bar type, cutting the gate and runner bar and polishing. These alloys were put about 30g/charge in the ceramic crucible of high frequency induction centrifugal casting machine and heat, Infrared thermal image analyzer indicated alloys in the crucible were set and operated. Results: The melting temperatures of these alloys measuring infrared thermal image analyzer were decreased in comparison with remanium$^{(R)}$ GM 800+, vera PDI$^{TM}$, Biosil$^{(R)}$ f, WISIL$^{(R)}$ M type V, Ticonium 2000 alloys of ingot type and vera PDS$^{TM}$(Aabadent, USA), Regalloy alloys of shot type. Conclusion: Co-Cr-Mo based alloy in addition to Sn(#Gr I alloy) were decreased the melting temperature with heating time of high frequency induction centrifugal casting machine using infrared thermal image analyzer.

$CO_2$ 레이저빔을 이용한 예민화된 Alloy 600의 급속응고 미세구조 연구 (Study on microstructure of sensitized Alloy 600 rapidly solidified by a $CO_2$ laser beam)

  • 임연수;서정훈;국일현;김정수
    • 한국레이저가공학회지
    • /
    • 제1권1호
    • /
    • pp.18-23
    • /
    • 1998
  • A Study on microstructural changes of sensitized Alloy 600 which was rapidly solidified by a $CO_2$ laser beam was conducted using microscopic equipments such as SEM and TEM. Dissolution of Cr-rich carbides and resultant Cr recovery on the grain boundaries occurred in the heat affected zone (HZA). The microstructure of the laser melted zone (LMZ) having epitaxially solidified from the HAZ was mainly celluar-dendritic with the 〈100〉 crystallographic direction of growth. The Cr concentration was observed to increase along the cell bondaries, and tiny particles were distributed along the cell walls with tangled dislocations around them. Cr-rich carbides had been completely melted by the high density of a laser beam, and were not re-precipitated during the matrix solidification due to a fast cooling rate in the LMZ.

  • PDF

가공방법에 따른 치과용 합금의 기계적 특성 및 생물학적 안정성 평가 (Evaluation of Mechanical Characteristic and Biological Stability of Dental Alloys by the Manufacture Method)

  • 김치영;정인성
    • 한국콘텐츠학회논문지
    • /
    • 제11권3호
    • /
    • pp.293-301
    • /
    • 2011
  • 치과보철물의 소재는 생물 화학적, 물리적 안정성을 위하여 우수한 생체친화성이 요구된다. 그래서 본 연구에서는 새로운 기술인 레이저 선택용융 가공법으로 제작된 Co-Cr합금(SC시편), Ti합금(ST시편)을 일반적으로 사용되는 주조법으로 제작된 Co-Cr합금(CC시편), Ni-Cr합금(CN시편)과 비교분석하여 기계적 특성과 생물학적 안정성 평가를 실시하였다. 기계적 특성 평가를 위하여 인장시험을 통한 탄성계수를 측정하였다. 그리고 생물학적 안정성 평가를 위하여 유사체액(lactic acid-NaCl solution)을 이용한 용출물질 분석과 용출배지를 이용한 세포독성을 관찰하였다. 그 결과 레이저 선택용융 가공법으로 제작한 Co-Cr 합금이 주조법으로 제작한 Co-Cr합금보다 탄성계수가 높게 나타났다. 그리고 용출물질 분석과 세포독성 평가에서 레이저 선택용융 가공법으로 제작한 Co-Cr합금의 생물학적 안정성이 양호한 것으로 평가되었다. 결과에 의하여 레이저 선택용융 가공법으로 제작한 합금이 치과보철물 제작을 위한 합금으로 적용할 수 있는 것으로 판단된다.

이종금속간의 결합방법에 따른 결합강도에 관한 비교 연구 (Comparative analysis on mechanical properties of gold and Co-Cr dental alloys due to joining methods)

  • 박성규;최부병;권긍록
    • 구강회복응용과학지
    • /
    • 제19권2호
    • /
    • pp.75-86
    • /
    • 2003
  • The purpose of this study was to evaluate their mechanical properties after laser-welding or soldering of precious and non-precious dental alloys. For this study, 30 Co-Cr alloy specimens, 15 gold alloy specimens, 15 palladium alloy specimens were casted and seperated on the middle area. 15 sperated Co-Cr specimens and 15 seperated gold alloy specimens were laser welded (GW Group). 15 sperated Co-Cr specimens and 15 sperated gold alloy specimens were soldered by coventional soldering method (GS Group). 15 sperated Co-Cr specimens and 15 seperated palladium alloy specimens were laser welded (PW Group). 15 sperated Co-Cr specimens and 15 sperated palladium alloy specimens were soldered by coventional soldering method (PS Group). Tensile strength, 0.2% yield strength, % elongation were recorded in nine specimens of each group. Bending strength were record in six specimens of each group. These data for four groups were subjected to a two-way analysis of variance(ANOVA). The fracture locations, fractured surfaces were examined by SEM(scanning electron microscope). The results were as following: 1) In the same alloy combination, the tensile strength and 0.2% yield strength and of the laser welded group with same metal combination were significantly less than soldered groups(p<0.05). 2) In the combination of Co-Cr/Palladium, the bending strength of laser welded group were significantly less than that of soldered groups(p<0.05). In the combination of Co-Cr/Gold, the bending strength of laser welded group were significantly higher than that of soldered groups(p<0.05). 3) In the same method of joint, the tensile strength and 0.2% yield strength and bending strength of the Co-Cr/gold were significantly higher than Co-Cr/palladium(p<0.05). 4) There was no significantly statistical difference between each group in the % elongation(p>0.05). 5) The fracture of the laser welded specimens occured in the welding area and a large void was observed at the center of the fracture surface. 6) The fracture of the soldered specimens occured also inthe soldered area and many porpsities were showed at the fracture sites.

$CoCr_{16.2}Pt_{10.8}Ta_4$ 합금박막의 Ti 우선증착에 따른 자기적 특성과 자구형상변화 (Magnetic properties and the shapes of magnetic domain for $CoCr_{16.2}Pt_{10.8}Ta_4$ alloy films with the prior deposition of Ti layer)

  • 이인선;김동원
    • 한국결정성장학회지
    • /
    • 제10권1호
    • /
    • pp.17-22
    • /
    • 2000
  • 수직보자력이 크고 CoCrPt에 비하여 noise 저감 효과가 큰 것으로 알려진 CoCrPtTa계 합금박막의 수직이방성을 더욱 개선하기 위해 Ti를 우선 증착하였다. 본 연구에서는 Ti 두께 변화에 따른 비교적 높은 수직보자력치를 보였던 $CoCr_{16.2}Pt_{10.8}Ta_4$Ti/glass 시편에서 자기적 특성과 자구형상의 변화를 살펴보았다. 또한 VSM(Vibrating Sample Magnetometer)을 이용하여 M-H loop를 측정하였으며 자구형상은 MFM(Magnetic Force Microscopy)로 관찰하였다. 육방정 Ti가 하지층으로서 우선증착되면 bare glass 직접 증착되는 경우보다 CoCrPtTa 자성층의 수직이방성에 현저한 향상을 가져왔으며 Ti의 두께가 두꺼울수록 c-축 배향성도 개선되었다. MFM 결과에 의하면 Ti두레가 20 nm에서 90 nm로 증가함에 따라 자구형상이 연속적인 stripe type에서 mass type으로 분절된 형태로 변하였다. 이는 Ti의 증착이 비자성 Cr 편석 거동에 영향을 미쳐 자화반전시 인접 columnar grain의 자화벡터들간의 상호교환작용을 억제하는 자기적 분리 효과에 기여했음을 의미한다. 아울러 이와 같은 거동은 Ti가 CoCr계 자성층의 수직이방성을 개선하는데 있어서 형상자기이방성적인 측면에서의 기여가 현저함을 의미하기도 한다.

  • PDF

도재용착주조관용 Co-Cr계 비귀금속 합금의 전단결합강도 비교평가에 관한 연구 (The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal)

  • 김희진;김부섭
    • 대한치과기공학회지
    • /
    • 제32권3호
    • /
    • pp.195-207
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.

Pt 함량에 따른 CoCrPt 합금박막의 국소보자력 분포 변화 (Variation of Local Coercivity Distribution in CoCrPt Alloy Films with Pt Composition)

  • 임미영;최석봉;신성철
    • 한국자기학회지
    • /
    • 제12권1호
    • /
    • pp.20-23
    • /
    • 2002
  • CoCrPt 합금박막의 국소보자력 분포를 400nm공간분해능으로 8000개의 국소영역을 동시에 측정할 수 있는 광자기 현미경 자력계로 관찰하였다. 시료들은 dc 마그네트론 스퍼터링 방식으로 Pt 함량을 6 at.%에서 28 at.%로 변화시키며 제작되었다. Pt 함량이 증가함에 따라 ,국소보자력 분포가 정규분포에서 비정규분포로 변화하며 국소보자력 분포폭이 증가함을 발견하였다. 투과전자현미경으로 관찰한 미세구조를 분석한 결과는 국소보자력 분포 변화가 결정립의 크기 분포 및 평균크기 변화와 깊이 연관되어 있음을 나타내었다.