Browse > Article
http://dx.doi.org/10.14347/kadt.2010.32.3.195

The study on Comparison Evaluation of Shear Bond Strength of Co-Cr Based Alloy using for Porcelain Fused Metal  

Kim, Hee-Jin (Department of Dental Laboratory Science, Graduate School of Life Sciences, Catholic University of Pusan)
Kim, Bu-Sob (Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan)
Publication Information
Journal of Technologic Dentistry / v.32, no.3, 2010 , pp. 195-207 More about this Journal
Abstract
Purpose: The purpose of this study was to observe the microstructural changes of surface in the specimens, performing the shear bond strength testing. The currently most used non-precious alloys are nickel-chromium based alloys with or without beryllium. However, their biocompatibility has been questioned concerning possible damages to the health of the patient and professionals involved in the fabrication of prosthesis caused by long exposure to Ni and Be. An option to nickel-chromium alloys is the cobalt-chromium alloy, an alternative that does not sacrifice the physical properties of the metal porcelain systems. Studies in the animals substantially show that the cobalt-chromium alloys are relatively well tolerated, being therefore more biocompatible than the nickel-chromium alloys. Methods: Non-addition Be to nickel-chromium based alloy(Bellabond plus) and cobalt-chromium alloy which has been widely used(Wirobond C) fused with ZEO light porcelain classified control group and cobalt-chromium alloy which is developing alloy of Alphadent company in Korea(Alphadent alloy) fused with ZEO light porcelain classified experimental group. The specimens of $4mm{\times}4mm{\times}0.5mm$ were prepared as-cast and as-opaque to cast body to analyze the mechanical characteristic change, the microstructure of alloy surface. The phase change was used to observe through XRD analysis and OM/SEM was used to observe the surface of specimens as-cast and as-opaque to cast body. Chemical formation of their elements was measured with EDS. Then hardness was measured with Micro Vicker's hardness tester. Shear bond strength test thirty specimens of $10mm{\times}10mm{\times}2mm$ was prepared, veneered, 3mm high and 3mm in diameter, over the alloy specimens. The shear bond strength test was performed in a universal testing machine(UTM) with a cross head speed of 0.5mm/min. Ultimate shear bond strength data were analyzed with one-way ANOVA and the Scheffe's test (P<0.05). Within the limits of this study, the following conclusions were drawn: The X-ray diffraction analysis results for the as-cast and as-opaque specimens showed that the major relative intensity of Bellabond plus alloy were changed smaller than Wirobond C and Alphadent Co-Cr based alloys. Results: Microstructural analysis results for the opaque specimens showed all the alloys increased carbides and precipitation(PPT). Alphadent Co-Cr based alloy showed the carbides of lamellar type. The Vickers hardness results for the opaque specimens showed Wirobond C and Alphadent Co-Cr based alloys were increaser than before ascast, but Bellabond plus alloy relatively decreased. The mean shear bond strengths (MPa) were: 33.11 for Wirobond C/ZEO light; 25.00 for Alphadent Co-Cr alloy/ZEO light; 18.02 for Bellabond plus/ZEO light. Conclusion: The mean shear bond strengths for Co-Cr and Ni-Cr based alloy were significantly different. But the all groups showed metal-metal oxide modes in shear bond strengths test at the interface.
Keywords
Cobalt-chromium alloy; X-ray diffraction analysis; SEM; EDS; Micorstructure; Vicker's hardness; Shear bond strength;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 O'connor RP, Mackert JR, Myers ML, Parry EE. Castability, opaque masquing, and porcelain bonding of 17 porcelains fused to metal alloys. J Prosthet Dent, 75, 367-374, 1996.   DOI   ScienceOn
2 Kenneth J. Anusavice. Phillips'Science of Dental materials, Eleventh Edition. Philadelphia Saunders: 89-90, 562-620, 2006.
3 Mariana P, Edson H, Marco AB, Rander PA. Evaluation of Shear bond strength of the union between two Co-Cr alloys and a dental ceramic. J Appl oral Sci, 12(4), 280-4, 2004.   DOI
4 Papazoglou E, Brantley WA. Porcelain adherence vs force to failure for palladium-gallium alloys: a critique of metal-ceramic bond testing. Dent Mater, 14(2), 112-119, 1998.   DOI   ScienceOn
5 Renata Marques de Mole, Alessandro Caldas Travassos, Maximiliano Piero Neisser. Shear bond strengths of a ceramic system to alternative metal alloys. J Prosthet Dent, 93, 64-9, 2005.   DOI   ScienceOn
6 Renato Morales Joias. Shear bond strength of a ceramic to Co-Cr alloys. J Prosthet Dent, 99, 54-59, 2008.   DOI   ScienceOn
7 Stephane V, Francis D, Guillaume M, Grigitte G. Combination fixed and removable prostheses using a Co-Cr alloy: A clinical report. J Prosthet Dent, 96, 100-3, 2006.   DOI   ScienceOn
8 Turan K. Comparative evaluation of bond strength of various metal-ceramic restorations. Materials and Design, 30, 445-451, 2009.   DOI   ScienceOn
9 김기원. 도재용착용 Co-Cr 합금과 Ni-Cr 합금의 도재전단결합강도 비교. 부산가톨릭대학교 생명과학대학원 석사학위 논문, 2009.
10 김치영. 치과 도재 용착 주조관용 Ni-Cr 합금의 Nb 첨가에 따른 계면 특성 변화 연구. 인제대학교대학원 박사학위 논문, 2004.
11 김치영, 최성민. 금속소부도재관용 Ni-Cr 합금에 첨가된 Nb이 계면특성에 미치는 영향. 대한치과기공학회지, 27, 1, 97-104, 2005.   과학기술학회마을
12 안종철. 도재소부용 Ni-Cr-Mo계 치과용 합금의 미세조직 및 기계적 성질. 전남대학교 대학원 석사학위논문, 2006.
13 이해형. 금속-세라믹 수복 시스템을 위한 3점 및 4점 굽힘 결합시험의 평가. 단국대학교 대학원 석사 학위논문, 2005.
14 최범웅. 치과용 니켈-크롬 합금의 베릴륨 유무에 따른 성분차이가 주조성에 미치는 영향. 경희대학교 대학원 치의학과 석사학위 논문, 2008.
15 Alf E, Carl-FA, Anders J. A Clinical Evaluation of Co-Cr Metal-Ceramic Fixed Partial Denture and Crwon: A three-to Seven-year Retrospective Study. J ProsthetDent, 98, 6-16, 2007.
16 Bezzon OL, de Mattos MG, Ribeiro RF, Rollo JM. Effect of beryllium on the castability and resistance of ceramometal bonds in nichkelchromium alloy. J Prosthet Dent, 80(5), 570-4, 1998.   DOI   ScienceOn
17 James C. Amir BM, Lucy DS, Ivar A, Mairn HF. The safety of nikel containing dental alloys. Dental materials, 22, 1163-1168, 2006.   DOI   ScienceOn
18 Bezzon OL, Ribeiro RF, Rollo JM, Crosara S. Castability and resistance of ceramometal bonding in Ni-Cr and Ni-Cr-Be alloys. J Prosthet Dent Mar, 85(3), 299-304, 2001.   DOI   ScienceOn
19 Craig RG. Restorative dental materials ed.10. Mosby-Year Book Inc: 409-412,493, 1997.
20 Hammad IA, Talic YF. Designs of bond strength tests for metal-cearmic complexes: review of the literature. J Prosthet Dent 75(6), 602-608, 1996.   DOI   ScienceOn