Browse > Article
http://dx.doi.org/10.5392/JKCA.2011.11.3.293

Evaluation of Mechanical Characteristic and Biological Stability of Dental Alloys by the Manufacture Method  

Kim, Chi-Young (부산가톨릭대학교 보건과학대학 치기공학과)
Chung, In-Sung (부산가톨릭대학교 보건과학대학 치기공학과)
Publication Information
Abstract
The material of the dental prosthesis was required bio-compatibility for biological, chemical, and physical stabilities. This study was conducted the stability evaluation of mechanical, biological characteristics through comparing Co-Cr alloy(SC group), Ti alloy(ST group) made by the selective laser melting method with Co-Cr alloy(CC group), Ni-Cr alloy(CN group) made by the casting method. Modulus of elasticity for mechanical characteristic evaluation was measured by the tensile test. And we conducted the release material analysis using lactic acid-NaCl solution for the evaluation of biological stability and were observed cytotoxicity through the content of this release medium. Taking these results into account, the Co-Cr alloy made by the selective laser melting method was observed modulus of elasticity higher than he Co-Cr alloy made by the casting method. And the Co-Cr alloy made by the selective laser melting method had more superior biological stability than the other groups as the result of cytotoxicity evaluation through the release material analysis. By this results, we think that alloys made by the selective laser melting method can be applied as materials for making the dental prosthesis.
Keywords
Bio-compatiblilty; Modulus of Elasticity; Cell Survival Rate; Release Material; Selective Laser Melting;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 A. Waltimo and M. Kononen, "Maximal Bite Force and its Association with Signs and Symptoms of Cranio Mandibular Disorders in Young Finnish non-Patients", Acta Odontol Scand, Vol.53, No.4, pp.254-258, 1995.   DOI
2 L. Probster, "Compressive Strength of Two Modern All-Ceramic Crowns," Int J Prosthodont, Vol.5, No.5, pp.409-414, 1992.
3 D. A. Puleo, D. D. Huh, "Acute toxicity of metal ions in culture of osteogenic cells derived from bone marrow stromal cells," J. of Applied Biomaterials, Vol.6, No.2, pp.109-116, 1995.   DOI   ScienceOn
4 류정현, 오소택, 강경화, 김상철, "교정장치로 부터의 니켈과 크롬의 유리에 관한 연구", 대한치과교정학회지, Vol.33, No.5, pp.351-358, 2003.
5 김성준, 조광헌, 이규복, "수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교", 대한치과보철학회지, Vol.47, No.2, pp.148-155, 2009.   과학기술학회마을   DOI   ScienceOn
6 송용억, "레이저를 이용한 금속 시제품의 쾌속조형 기술현황" 대한용접접합학회, Vol.17, No.3, pp.8-12, 1999.   과학기술학회마을
7 민동준, "재료열역학", 홍릉과학출판사, 2009.
8 김철생, 박진수, 허억, 강곤, "초내식성 스테인리스강의 금속이온용출 특성 및 세포적합성", 의공학회지, Vol.17, No.1, pp.11-18, 1996.
9 권오성, 유재선, 박형호, 이오연, 이민호, 송기홍, "표면처리된 타이타늄과 타이타늄 합금의 표면특성 및 세포독성 평가", 대한금속재료학회지, Vol.43, No.7, pp.481-487, 2005.   과학기술학회마을
10 최득철, 방몽숙, 윤택림, "Ti-Ta-Nb계 합금의 세포독성과 생체적합성의 평가", 대한치과보철학회지, Vol.44, No.2, pp.250-263, 2006.   과학기술학회마을
11 이계형, 조진형, 이기헌, 황현식, "전기도금한 교정용 스테인레스 스틸 선재의 세포독성에 관한 연구" 대한치과교정학회지, Vol.35, No.2, pp.127-136, 2005.
12 정규철, "산업중독편람", 신광출판사, 1995.
13 한창수, 천재식, "치과 주조용 금합금에서 정상인 치은섬유모세포의 세포 독성 연구", 대한구강악안면병리학회지, Vol.29, No.4, pp.271-282, 2005.
14 Joon B. Park, Roberic S. Lakes, "Biomaterials an introduction," Division of Plenum Publishing Co., 1992.
15 최영진, 육정인, 정문규, "구강점막 상피세포에 대한 치과주조용 비귀금속합금의 세포독성", 대한치과보철학회지, Vol.37, No.6, pp.717-729, 1999.
16 A. Naji and M. F. Harmand, "Study of the effect of the surlace state on the cyctocompatability of a Co-Cr alloy using human osteoblasts and fibroblasts," J Biomed. Mater. Res., Vol.24, No.7, pp.861-871, 1990.   DOI
17 M. Yoshinari, T. Derand, "Fracture Strength of All-Ceramic Crowns", Int J Prosthodont, Vol.7, No.4, pp.329-338, 1994.