• Title/Summary/Keyword: Co/NPC

Search Result 15, Processing Time 0.031 seconds

Simulation of 3-Level NPC Inverter using Co-simulation of LabVIEW and Multisim (LabVIEW와 Multisim의 Co-simulation을 이용한 3-Level NPC Inverter의 시뮬레이션)

  • Kim, Sun-Tae;Ji, Jun-Keun
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.546-547
    • /
    • 2014
  • 본 논문에서는 LabVIEW와 Multisim을 이용한 Co-simultion 기능으로 얻은 시뮬레이션 결과와 그 과정을 기술한다. 3-Level NPC Inverter를 제어하였으며 동일한 조건에서 PSIM으로 시뮬레이션한 결과와 비교하여 보았다.

  • PDF

Embedding Cobalt Into ZIF-67 to Obtain Cobalt-Nanoporous Carbon Composites as Electrode Materials for Lithium ion Battery

  • Zheng, Guoxu;Yin, Jinghua;Guo, Ziqiang;Tian, Shiyi;Yang, Xu
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.458-464
    • /
    • 2021
  • Lithium ion batteries (LIBs) is a kind of rechargeable secondary battery, developed from lithium battery, lithium ions move between the positive and negative electrodes to realize the charging and discharging of external circuits. Zeolitic imidazolate frameworks (ZIFs) are porous crystalline materials in which organic imidazole esters are cross-linked to transition metals to form a framework structure. In this article, ZIF-67 is used as a sacrificial template to prepare nano porous carbon (NPC) coated cobalt nanoparticles. The final product Co/NPC composites with complete structure, regular morphology and uniform size were obtained by this method. The conductive network of cobalt and nitrogen doped carbon can shorten the lithium ion transport path and present high conductivity. In addition, amorphous carbon has more pores that can be fully in contact with the electrolyte during charging and discharging. At the same time, it also reduces the volume expansion during the cycle and slows down the rate of capacity attenuation caused by structure collapse. Co/NPC composites first discharge specific capacity up to 3115 mA h/g, under the current density of 200 mA/g, circular 200 reversible capacity as high as 751.1 mA h/g, and the excellent rate and resistance performance. The experimental results show that the Co/NPC composite material improves the electrical conductivity and electrochemical properties of the electrode. The cobalt based ZIF-67 as the precursor has opened the way for the design of highly performance electrodes for energy storage and electrochemical catalysis.

Simple Compensation Method of Unclamped Switch Voltages in a Three-Level NPC Inverter (3-레벨 NPC 인버터에서 클램핑되지 않는 스위치 전압의 간단한 보상기법)

  • Ji, Kyun-Seon;Jou, Sung-Tak;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.257-265
    • /
    • 2014
  • This paper proposes a simple compensation method for switches of the unclamped voltage in the three-level NPC inverter. Voltages of inner-switches can be unclamped in the three-level NPC (neutral point clamped) inverter. It can cause the problem of the switch fault accident. By adding a capacitor, switches of the unclamped voltage can be clamped. Through the analysis of the circuit, the reason behind switches being unclamped was verified which leads to the solution method that designs a compensation capacitor. The proposed method was validated through the simulation and experimental results.

A Method to Compensate the Distorted Space Vectors in the Unbalanced Neutral Point Voltage of 3-level NPC PWM Inverters

  • Hyun, Seung-Wook;Hong, Seok-Jin;Lee, Jung-Hyo;Lee, Chun-Bok;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.455-463
    • /
    • 2016
  • This paper proposes a compensation method to improve the distorted space vectors when a 3-level Neutral Point Clamped (NPC) inverter has an unbalanced neutral point voltage. Since both the neutral point voltage of the DC link and the space vector of a 3-level NPC inverter are closely related depending on the output load connecting state, a distorted space vector can occur when the neutral point voltage of a 3-level NPC inverter is unbalanced. The proposed method can improve the distorted space vectors by adjusting the injection time of the small and medium vectors and by modulating the amplitude of the carrier waveforms. In this paper, the proposed method is verified by both simulation and experimental results based on a 3-level NPC inverter.

Transcriptional regulation of Niemann-Pick C1-like 1 gene by liver receptor homolog-1

  • Lee, Eui Sup;Seo, Hyun Jung;BacK, Su Sun;Han, Seung Ho;Jeong, Yeon Ji;Lee, Jin Wook;Choi, Soo Young;Han, Kyuhyung
    • BMB Reports
    • /
    • v.48 no.9
    • /
    • pp.513-518
    • /
    • 2015
  • Factors that modulate cholesterol levels have major impacts on cardiovascular disease. Niemann-Pick C1-like 1 (NPC1L1) functions as a sterol transporter mediating intestinal cholesterol absorption and counter-balancing hepatobiliary cholesterol excretion. The liver receptor homolog 1 (LRH-1) had been shown to regulate genes involved in hepatic lipid metabolism and reverse cholesterol transport. To study whether human NPC1L1 gene is regulated transcriptionally by LRH-1, we have analyzed evolutionary conserved regions (ECRs) in HepG2 cells. One ECR was found to be responsive to the LRH-1. Through deletion studies, LRH-1 response element was identified and the binding of LRH-1 was demonstrated by EMSA and ChIP assays. When SREBP2, one of several transcription factors which had been shown to regulate NPC1L1 gene, was co-expressed with LRH-1, synergistic transcriptional activation resulted. In conclusion, we have identified LRH-1 response elements in NPC1L1 gene and propose that LRH-1 and SREBP may play important roles in regulating NPC1L1 gene. [BMB Reports 2015; 48(9): 513-518]

A Study on Development of Indoor Object Tracking System Using N-to-N Broadcasting System (N-to-N 브로드캐스팅 시스템을 활용한 실내 객체 위치추적 시스템 개발에 관한 연구)

  • Song, In seo;Choi, Min seok;Han, Hyun jeong;Jeong, Hyeon gi;Park, Tae hyeon;Joeng, Sang won;Kwon, Jang woo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.192-207
    • /
    • 2020
  • In industrial fields like big factories, efficient management of resources is critical in terms of time and expense. So, inefficient management of resources leads to additional costs. Nevertheless, in many cases, there is no proper system to manage resources. This study proposes a system to manage and track large-scale resources efficiently. We attached Bluetooth 5.0-based beacons to our target resources to track them in real time, and by saving their transportation data we can understand flows of resources. Also, we applied a diagonal survey method to estimate the location of beacons so we are able to build an efficient and accurate system. As a result, We achieve 47% more accurate results than traditional trilateration method.

Gamma Knife Radiosurgery Using Co-Registration with PET-CT and MRI for Recurrent Nasopharyngeal Carcinoma with Previous Radiotherapy : A Single Center 14-Year Experience

  • Lee, Chaejin;Park, Seong-Hyun;Yoon, Sang-Youl;Park, Ki-Su;Hwang, Jeong-Hyun;Hwang, Sung-Kyoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.397-405
    • /
    • 2020
  • Objective : We retrospectively evaluated the efficacy of Gamma Knife radiosurgery (GKS) for recurrent nasopharyngeal carcinoma (NPC) in patients who previously underwent radiotherapy, and analyzed the treatment outcomes over 14 years. Methods : Ten patients with recurrent NPC who had previously received radiotherapy underwent stereotactic radiosurgery using a Gamma Knife® (Elekta Inc, Atlanta, GA, USA) between 2005 and 2018. The median target volume was 8.2 ㎤ (range, 1.7-17.8), and the median radiation dose to the target was 18 Gy (range, 12-30). The median follow-up period was 18 months (range, 6-76 months). Overall and local failure-free survival rates were determined using the Kaplan-Meier method. Results : The NPCs recurred at the primary cancer site in seven patients (70%), as distant brain metastasis in two (20%), and as an extension into brain in one (10%). The recurrent tumors in seven of the 10 patients (70%) were found on the routine follow-up imaging studies. Two patients presented with headache and one with facial pain. Local failure after GKS occurred in five patients (50%) : two of whom died eight and 6 months after GKS, respectively. No adverse radiation effects were noted after GKS. The 1- and 3-year overall survival rates after GKS were 90% and 77%, respectively. The local failure-free survival rates at 6 months, 1 year, and 3 years after GKS were 80%, 48%, and 32%, respectively. The median interval from GKS to local failure was 8 months (range, 6-12). Univariate analysis revealed that using co-registration with positron emission tomography-computed tomography (PET-CT) and magnetic resonance imaging (MRI) was associated with a lower local failure rate of recurrent NPC (p=0.027). Conclusion : GKS is an acceptable salvage treatment option for patients with recurrent NPC who previously received radiation therapy. PET-CT and MRI co-registration for dose planning can help achieve local control of recurrent NPC.

SVPWM Overmodulation Scheme of Three-Level Inverters for Vector Controlled Induction Motor Drives

  • Kwon, Kyoung-Min;Lee, Jae-Moon;Lee, Jin-Mok;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.481-490
    • /
    • 2009
  • This paper describes a SVPWM overmodulation scheme of NPC type three-level inverter for traction drives which extends the modulation index from MI=0.907 to unity. SVPWM strategy is organized by two operation modes of under-modulation and over-modulation. The switching states under the under-modulation modes are determined by dividing them with two linear regions and one hybrid region the same as the conventional three-level inverter. On the other hand, under the over-modulation mode, they are generated by doing it with two over-modulation regions the same as the conventional over-modulation strategy of a two level inverter. Following the description of over-modulation scheme of a three-level inverter, the system description of a vector controlled induction motor for traction drives has been discussed. Finally, the validity of the proposed modulation algorithm has been verified through simulation and experimental results.

The Development of High Power 3 Level Inverter based on FPGA

  • Peng, Xiao-Lin;Bayasgalan, D;Ryu, Ji-Su;Lee, Sang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.315-316
    • /
    • 2012
  • Three-level neutral point clamping (NPC) converter has been widely applied in high power drive system. And in this paper, a novel method is proposed to realize this algorithm based on FPGA, And the system is consist of two parts, the DSP part and FPGA part, the DSP part includes the control algorithms and the FPGA part works to generate and putout 12 PWM pulses. And the system is tested and verified using both simulation and experimentation.

  • PDF

THE THERAPEUTIC EFFECT OF SILVER NANOCRYSTALLINE OINTMENT ON TMJ CAPSULITIS (은 나노 연고가 측두하악관절낭염의 환자의 치료에 미치는 영향에 관한 연구)

  • Chae, Chang-Hoon;Kim, Jwa-Young;Kim, Mi-Ja;Chung, Hoon;Kim, Seung-Ho;Oh, Hyun-Woo;Kim, Young-Nam;Kim, Young-Il;Yang, Byung-Ho;Kim, Seong-Gon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.262-266
    • /
    • 2006
  • The silver nanocrystalline is widely used for biological field because of its biocompatibility and anti-microbial effect. The objective of this study was to evaluate the therapeutic efficacy of the silver nanocrystalline ointment on the temporomandibular joint (TMJ) capsulitis. Total 39 patients were included in this study and all patients were received single topical application of the silver nanocrystalline ointment (group A, n=30) or placebo ointment (group B, n=19). Measured variables were maximum mouth opening (MMO), visual analog scale (VAS) for pain, and VAS for function. In results, we could not assess any therapeutic efficacy of single application in the chronic TMJ capsulitis (p>0.05). However, the single application of silver nanocrystalline ointment showed significant improvement in MMO and VAS for pain compared to placebo effect in the acute TMJ capsulitis (p<0.05). We could not find any complications related to ointment application in both groups. In conclusion, the single application of silver nanocrystalline ointment was effective in improving patient's symptom in acute TMJ capsulitis without any noticing complications.