• Title/Summary/Keyword: Closed technique

Search Result 755, Processing Time 0.029 seconds

Initial Frequency Preset Technique for Fast Locking Fractional-N PLL Synthesizers

  • Sohn, Jihoon;Shin, Hyunchol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.4
    • /
    • pp.534-542
    • /
    • 2017
  • This paper presents a fast locking technique for a fractional-N PLL frequency synthesizer. The technique directly measures $K_{VCO}$ on a chip, computes the VCO's target tuning voltage for a given target frequency, and directly sets the loop filter voltage to the target voltage before the PLL begins the normal closed-loop locking process. The closed-loop lock time is significantly minimized because the initial frequency of the VCO are put very close to the desired final target value. The proposed technique is realized and designed for a 4.3-5.3 GHz fractional-N synthesizer in 65 nm CMOS and successfully verified through extensive simulations. The lock time is less than $12.8{\mu}s$ over the entire tuning range. Simulation verifications demonstrate that the proposed method is very effective in reducing the synthesizer lock time.

TUNNEL TRACTION OF IMPACTED MAXILLARY CANINES (매복된 견치의 Tunnel을 통한 교정적 견인)

  • Jeon, Jeong-Hoon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2005
  • The impacted maxillary canine is a common problem of which all dental practitioners should be aware. The surgical orthodontic treatment of impacted canines is replaced correction position in dental arch without periodontal damage. Many treatment possibilities have been considered for this goal; window procedure, apically positioned flap, closed eruption technique and tunnel traction. Prognosis for these treatment may be very uncertain in many case(infraosseous impacted tooth). Other steps are required to achieve a satisfactory periodontal outcome. Satisfactory results could be expected if the physiologic eruption pattern is restored by tunnel traction, because permanent tooth erupts through the gingiva near the crest of the ridge so that periodontal damage is reduced. This article report that the surgical orthodontic treatment using tunnel traction is obtained proper position and reduced periodontal damage in facially impacted maxillary canines.

  • PDF

Fabrication of complete denture using Centric tray and closed mouth technique for edentulous patient (과도한 치조제 흡수를 보이는 무치악 환자에서 Centric tray와 폐구법 인상을 이용한 총의치 수복 증례)

  • Jung, Sua;Ma, Boyoung;Yang, Hongso;Park, Sangwon;Lim, Hyun-Pil;Yun, Kwidug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.120-125
    • /
    • 2018
  • Conventional denture impression techniques have limitations for edentulous patients with severe alveolar bone resorption and can cause problems from excessive border extension. Especially when a patient has movable tissue it is difficult to make accurate impression, thus might interrupt stable seating of complete denture. Fabrication of complete denture using closed mouth technique for edentulous patient with severe ridge resorption is thought to provide better stability and retention. In this case, an 86-year-old patient had both edentulous jaws with epulis fissuratum on maxillary anterior ridge and severe mandibular ridge resorption. Thus, tentative vertical dimension was determined by using Centric trayand individual tray attached with gothic arch tracer was fabricated. Complete denture was fabricated using closed mouth technique and the patient was satisfied with better stability and retention of the complete denture.

Complete denture rehabilitation of edentulous patient with severe alveolar bone resorption using mandibular suction denture with closed mouth technique: a clinical report (치조골 흡수가 심한 완전 무치악 환자에서 폐구인상법을 이용한 총의치 수복 증례)

  • Ko, Chang Woo;Min, Byungkwee;Yang, Hong-so;Lim, Hyun-Pil;Yun, Kwidug;Shin, Jin-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • When it comes to treat patient with loss of vestibule, conventional denture impression have limitation which can cause problems of excessive border extension. Suction denture with closed mouth technique which was introduced to solve this problem, forms negative pressure being sealed denture flanges by mobile mucosa when the patient swallows and chews. Also, it can decrease patient's visiting time by taking impression and gothic arch tracing at once. In this case, considering patient's chief complain which is a loose fit of present lower denture, suction dentures with closed mouth technique was planned.

A comparative study on the accuracy of impression body according to the types of impression tray (임플란트 인상 채득 시 트레이 종류에 따른 인상체의 정확도에 관한 비교 연구)

  • Yi, Hyun-Jung;Lim, Jong-Hwa;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.48-54
    • /
    • 2010
  • Purpose: The objective of this study was to evaluate and compare the accuracy of impression body taking by the closed and the open tray impression technique with 3 types of impression tray. Individual tray, metal stock tray and polycarbonate tray were used. Materials and methods: Nine closed tray impressions were taken by individual tray, metal stock tray and polycarbonate stock tray, respectively with polyether impression material. 9 open tray impressions were also acquired by same manner. Precision analysis on the master models was performed by attaching the reference frameworks with alternate single screws and measuring the vertical fit discrepancy of respective analogues in working cast with a stereo microscope. Data were analyzed by 1 way ANOVA and independent t-test. Results: The average fit accuracy of impression bodies was calculated. With the closed tray impression technique, there were significant statistical differences in vertical fit discrepancy according to the types of tray. The individual tray group showed the lowest value and the polycarbonate stock tray group represented the highest. With the open tray impression technique, there was no significant difference in vertical fit discrepancy. Significant statistical difference in vertical fit discrepancy was found between the open and the closed impression technique with the polycarbonate stock tray. Conclusion: From the results above, more precise impressions could be acquired by the rigid individual tray compared with the polycarbonate stock tray. It was hard to get consistent accuracy impressions by the closed tray impression technique with polycarbonate stock trays.

Dynamic Analysis of Flexible Mechanical System (폐쇄계를 포함하는 탄성 기계시스템의 동역학적 해석)

  • 안덕환;이병훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.1
    • /
    • pp.271-276
    • /
    • 1995
  • This paper presents a systematic method for the dynamic analysis of flexible mechanical systems containing closed kinematic loops. Kinematics between pairs of contiguous flexible bodies is described with the joint coordinates and the deformation modal coordinates. The cut-joint constraint equations associated with the closed kinematic loops are derived, simply using the geometric conditions. The equations of motions are initially written in terms of the joint and modal coordinates using the velocity transformation technique. Lagrange multipliers associated with the cut-joint constraints for closed-loop systems are then eliminated systematically using the generalized coordinate partitioning method, resulting to a minimal set of equations of motion.

Surgical Treatment of Mitral Valvular Disease (승모판막질환의 수술)

  • 이인성
    • Journal of Chest Surgery
    • /
    • v.12 no.2
    • /
    • pp.127-134
    • /
    • 1979
  • During the 4 years period to be reported, 34 operations were performed on the mitral valve in the department of Thoracic and cardiovascular surgery, Korea University hospital, from Aug. 1975 to April 1979. At the first 1-year period, the closed technique was used in 12 patients. After that, open-heart surgery was used routinely; 8 patients had open mitral commissurotomy and 14 patients had valve replacement. There were 18 men and 16 women with sex ratio of 1.1: 1. The age of the patients varied widely from 18 years of the youngest to 46 years of the oldest-average aged of 32.5 years. All had symptoms and the mean duration of symptoms was 6 years and 1 month. Preoperative atrial fibrillation was 47% and embolizations were in 3 of 34 patients. The operative mortality was none for the closed and 14% for the open technique combined rate of 9 per cent which were valve thrombosis, brain embolism and left pulmonary vein rupture in deauriculization. But surviving patients undergoing open heart surgery enjoyed symptomatic benefits comparable to these of the patients of closed.

  • PDF

Closed-Die Forging Analysis of Clutch Teeth Using An Upper Bound Elemental Technique (상계요소법에 의한 클러치 치형의 밀폐단조해석)

  • 양정호;이상태;김용조
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.134-138
    • /
    • 1996
  • A simple kinematically admissible velocity field for closed-die forging of clutch teeth is analysed which takes account of the profiled teeth chosen kinematically by approximating these as straight taper teeth. The upper bound load and the deformed configurations are predicted by the velocity field at varying punch movements considering differing frictional factors. Experiments were carried out using a model material of plasticine at room temperature where talcum powder was used as a lubricant. The theoretical predictions of the forging load and the relative pressures are found to be in reasonably good agreement with the experimental results.

  • PDF

Closed-Die Forging Analysis of Spling-LikeComponents (스플라인 기어류의 폐쇄단조 해석)

  • Lee, Seung-Dong;Kim, Won-Il;Kim, Yohng-Jo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.187-194
    • /
    • 1999
  • Closed-die forging of spline was analysed using the upper bound elemental technique, Two different forging methods, denoted here as side extrusion-forging and upset forging, were proposed, The kinematically admissible velocity fields for each of the forging methods, which could express trapezoidal, rectangular and serration tooth forms, were presented. Upper bounds to forging loads and deformed configurations were predicted using the velocity fields. Theoretical results were compared with experimental ones. Experiments with lead were carried out at room temperature where grease was used as a lubricant. The present investigation revealed that analytical forging loads were reduced by using the side extrusion-forging but the upset forging could improve configuration of the final forged splines.

  • PDF

Accuracy of a proposed implant impression technique using abutments and metal framework

  • Lee, Hyeok-Jae;Lim, Young-Jun;Kim, Chang-Whe;Choi, Jung-Han;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • PURPOSE. This study compared the accuracy of an abutment-framework (A-F) taken with open tray impression technique combining cement-on crown abutments, a metal framework and resin cement to closed tray and resin-splinted open tray impression techniques for the 3-implant definitive casts. The effect of angulation on the accuracy of these 3 techniques was also evaluated. MATERIAL AND METHODS. Three definitive casts, each with 3 linearly positioned implant analogs at relative angulations 0, 30, and 40 degrees, were fabricated with passively fitted corresponding reference frameworks. Ten impressions were made and poured, using each of the 3 techniques on each of the 3 definitive casts. To record the vertical gap between reference frameworks and analogs in duplicate casts, a light microscope with image processing was used. Data were analyzed by two-way analysis of variance and the Tukey test. RESULTS. The open tray techniques showed significantly smaller vertical gaps compare to closed tray technique (P < .05). The closed tray and the resin-splinted open tray technique showed significantly different vertical gaps according to the angulation of implant (P < .05), but the A-F impression technique did not (P > .05). CONCLUSION. The accuracy of the A-F impression technique was superior to that of conventional techniques, and was not affected by the angulation of the implants.