• 제목/요약/키워드: Chemical Sensor

검색결과 1,027건 처리시간 0.034초

Quasi-Solid-State Hybrid Electrolytes for Electrochemical Hydrogen Gas Sensor

  • Kim, Sang-Hyung;Han, Dong-Kwan;Hong, SeungBo;Jeong, Bo Ra;Park, Bok-Seong;Han, Sang-Do;Kim, Dong-Won
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권3호
    • /
    • pp.294-301
    • /
    • 2019
  • The quasi-solid-state hybrid electrolytes were synthesized by chemical cross-linking reaction of methacrylate-functionalized $SiO_2$ ($MA-SiO_2$) and tetra (ethylene glycol) diacrylate in aqueous electrolyte. A quasi-solid-state electrolyte synthesized by 6 wt.% $MA-SiO_2$ exhibited a high ionic conductivity of $177mS\;cm^{-1}$ at room temperature. The electrochemical $H_2$ sensor assembled with quasi-solid-state electrolyte showed relatively fast response and high sensitivity for hydrogen gas at ambient temperature, and exhibited better durability and stability than the liquid electrolyte-based sensor. The simple construction of the sensor and its sensing characteristics make the quasi-solid-state hydrogen sensor promising for practical application.

소형전극 어레이로 구성한 흐름계형 전자혀 (Electronic Tongue Composed of Mini-Electrode Array in Flow Cell)

  • 심준호;심재훈;서성석;오현준;한종호;남학현;차근식
    • 분석과학
    • /
    • 제17권3호
    • /
    • pp.217-224
    • /
    • 2004
  • 소형의 이온선택성 전극을 흐름계 어레이로 구성하여 전자혀 시스템을 제작하였다. 제작된 전자혀 시스템에 음용수 및 알코올성 음료를 저 농도의 완충용액 (0.005 M Tris-$H_2SO_4$ pH 7.2)에 묽힌 후 9개의 전극이 장착된 흐름계에 흘려 보내어 전위차를 측정하였다. 얻어진 자료는 주성분 분석 (principal component analysis; PCA)을 통하여 식음료의 맛을 평가할 수 있도록 2차원 및 3차원 좌표계에 표시하였다. 본 연구에서 제작한 전자혀 시스템은 식품의 생산공정관리의 목적으로 또는 시중에서 구할 수 있는 식음료 맛의 변화 추이를 구분해 내는 목적으로 유용하게 사용될 수 있다.

An off-on Fluorescent Sensor for Detecting a Wide Range of Water Content in Organic Solvents

  • Kim, Kang-Hyeon;Lee, Wan-Jin;Kim, Jae Nyoung;Kim, Hyung Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권8호
    • /
    • pp.2261-2266
    • /
    • 2013
  • This paper describes the synthesis and water sensing properties of a fluorescent photoinduced electron transfer (PET) sensor (5) with an extended operating sensing range. The 1,8-naphthalimide derivative (5) attached with a piperazine group and a carboxylic group was synthesized and applied as a fluorescent water sensor in water-miscible organic solvents. The fluorescence intensity of the dye 5 increased with increasing water content up to 80% (v/v) and the fluorescence intensities were enhanced 45-, 67- and 122-fold in aqueous EtOH, DMF and DMSO solutions, respectively. In aqueous acetone solution, the enhancement of the fluorescence intensities was somewhat lower (30-fold) but the response range was wider (0-90%, v/v).

화학 센서 기술 (Chemical sensors technology)

  • 이덕동
    • 센서학회지
    • /
    • 제18권1호
    • /
    • pp.1-21
    • /
    • 2009
  • There have been continued effects to develop various types of chemical sensors according to the demands in many application fields such as safety, pollution, environment, medical engineering and food industries etc. In this review, the author intended to cover the general aspects of chemical sensors, including the history of the development, the classification, the sensing properties, and the types and application examples. And the future outlook of the chemical sensor technology, focusing on the advanced materials, high technology fusion, miniaturized intelligent system and ubiquitous sensor networks etc., has been described.

다중벽 탄소나노튜브를 이용한 철근 부식 검출 센서 제작 연구 (A study on the Corrosion Detection Sensor using Multi-Wall Carbon Nanotube)

  • 박수빈;김성연;이수정;최문정;홍영준;권성준;유봉영;윤상화
    • 한국표면공학회지
    • /
    • 제54권4호
    • /
    • pp.194-199
    • /
    • 2021
  • In this study, rebar corrosion detection sensor was fabricated using multi-walled carbon nanotubes (MWCNTs). MWCNTs were pre-treated in the acid electrolytes to attach the carboxylic acid to the surface of MWCNTs. The fabricated sensor was attached on the surface of rebar and it detected the corrosion of steel using LCR meter with variation of capacitance. The surface morphology and electrical properties were characterized using scanning electron microscope (SEM) and electrical test equipment, respectively. To verify the corrosion detection characteristics, comparison experiment using plastic bar was performed. Moreover, mechanism of corrosion detection sensor was discussed.

단일 조성 실온 경화형 실리콘러버를 지지체로 사용한 고체상 탄산이온선택성 전극의 개발 (One-component Room Temperature Vulcanizing-Type Silicone Rubber-Based Solid-State Carbonate Ion Selective Electrode)

  • 김미경;윤인준;조성호;신혜라;한종호;하정한;남학현;차근식
    • 대한화학회지
    • /
    • 제48권3호
    • /
    • pp.266-272
    • /
    • 2004
  • 소형 고체상 전극에 단일 조성 실온 경화형(one-component room temperature vulcanizing type) 실리콘러버 730(730 RTV)을 지지체로 도입하여 가소제가 필요 없는 탄산이온선택성 전극막을 개발하였다. 본 연구에서 최적화된 탄산이온선택성 전극막의 조성은 85.75 wt%의 730 RTV, 11.08 wt%의 trifluoroacetyl-p-decylbenzene(TFADB), 3.17 wt%의 tridodecyl-methylammonium chloride(TDMACl)로 제조 되었고, 우수한 전기화학적 특성(감응기울기 (26.3 mV/dec.), 선택성($logKT^{pot}_{CO_{2},Cl^-}$= -4.00, $logKT^{pot}_{TCO_{2},Sal^-}$=1.69), 검출한계(4.0${\times}10^{-4}M$))을 보였으며, 이와 같은 조성의 막을 도입한 평면형 고체상 센서는 60일 이상 초기특성을 유지하였다.

Sensor Applications of Thin-Film Transistors - Photosensor, Magnetic Sensor, Temperature Sensor and Chemical Sensor -

  • Kimura, Mutsumi;Miura, Yuta;Ogura, Takeshi;Hachida, Tomohisa;Nishizaki, Yoshitaka;Yamashita, Takehiko;Shima, Takehiro;Hashimoto, Hayami;Yamaguchi, Yohei;Hirako, Masaaki;Yamaoka, Toshifumi;Tani, Satoshi;Imuro, Yoshiki;Bundo, Kosuke;Sagawa, Yuki;Setsu, Koushi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.957-960
    • /
    • 2009
  • Sensor applications of thin-film transistors (TFTs), such as photosensor, magnetic sensor, temperature sensor and chemical sensor, are introduced. Active-matrix circuits and amplifying circuits using poly-Si TFTs are integrated with these sensors to improve sensor performances and generate additional functions. These sensors may be promising applications after flat-panel displays (FPDs) in giant-micro electronics.

  • PDF

Soft Lithographic Patterning Method for Flexible Graphene-based Chemical Sensors with Heaters

  • Kang, Min-a;Jung, Min Wook;Myung, Sung;Song, Wooseok;Lee, Sun Suk;Lim, Jongsun;Park, Chong-Yun;An, Ki-Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.176.2-176.2
    • /
    • 2014
  • In this work, we demonstrated that the fabrication of flexible graphene-based chemical sensor with heaters by soft lithographic patterning method [1]. First, monolayer and multilayer graphene were prepared by thermal chemical vapor deposition transferred onto SiO2 / Si substrate in order to fabrication of patterned-sensor and -heater. Second, patterned-monolayer and multilayer graphene were detached through soft lithography process, which was transferred on top and bottom sides of PET film. Third, Au / Ti (Thickness : 100/30 nm) electrodes were deposited end of the patterned-graphene line by sputtering system. Finally, we measured sensor properties through injection of NO2 and CO2 gas on different temperature with voltage change of graphene heater.

  • PDF

내부 최적화를 이용한 화학 센서의 단기 드리프트 분석 및 보정 (Short Term Sensor's Drift Analysis and Compensation Using Internal Normalization)

  • 전진영;백종현;변형기
    • 센서학회지
    • /
    • 제24권4호
    • /
    • pp.270-273
    • /
    • 2015
  • One of the main problems when working the chemical sensor is the lack of repeatability and reproducibility of the sensor response. If the problem is not properly taken into consideration, the stability and reliability of the system using chemical sensors would be decreased. In this paper we analyzed the sensor's drift of short term and proposed a compensation method for reducing the effects of the drift in order to improve the stability and the reliability of the chemical sensor. The sensor drift was analyzed by a trend line graph and CV(coefficient of variation) was used to quantify. And we compensated for the drift by using the internal normalization. As a result it was found that the value of CV was decreased after compensation.