• Title/Summary/Keyword: Charge

Search Result 10,847, Processing Time 0.037 seconds

Reliability Analysis by Lateral Charge Migration in Charge Trapping Layer of SONOS NAND Flash Memory Devices (SONOS NAND 플래시 메모리 소자에서의 Lateral Charge Migration에 의한 소자 안정성 연구)

  • Sung, Jae Young;Jeong, Jun Kyo;Lee, Ga Won
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.138-142
    • /
    • 2019
  • As the NAND flash memory goes to 3D vertical Silicon-Oxide-Nitride-Oxide-Silicon (SONOS) structure, the lateral charge migration can be critical in the reliability performance. Even more, with miniaturization of flash memory cell device, just a little movement of trapped charge can cause reliability problems. In this paper, we propose a method of predicting the trapped charge profile in the retention mode. Charge diffusivity in the charge trapping layer (Si3N4) was extracted experimentally, and the effect on the trapped charge profile was demonstrated by the simulation and experiment.

An Integration Study of the Firing Test Stage at the Acceptance Test for the Propelling Charge (추진장약 수락시험의 시험단계 통합 연구)

  • Kim, Jaekab;Kim, Jaehoon;Na, Taeheum;Kim, Bokyun;Park, Noseok
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 2016
  • In this paper, the integration of the firing test stages at the acceptance test of the propelling charge has been studied using statistical analysis on the basis of the test data of K676 and K677 propelling charge for K9 self propelled howitzer. Acceptance test of K676 / K677 propelling charge consists of 3 stages and each stage is charge assessment test, charge uniformity test and charge proving ground test. Many of rounds are fired and much money is spent to prove the charge performance at each stage. The result of t-test shows that there is no difference between charge uniformity and charge proving ground test stage of K676 and K677 propelling charge.

High-Efficiency Charge Pump for CMOS Image Sensor (CMOS 이미지 센서를 위한 고효율 Charge Pump)

  • Kim, Ju-Ha;Jun, Young-Hyun;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.50-57
    • /
    • 2008
  • In this paper, a high-efficiency charge pump for use in CMOS image sensor(CIS) is proposed. The proposed charge pump pursues high pumping efficiency by minimizing the switching and reversion losses by taking advantage of operation characteristics of CIS. That is, the proposed charge pump minimizes the switching loss by dynamically controlling the size of clock driver, pumping capacitor, and charge transfer switch based on the operation phase of CIS pixel sensor. The charge pump also minimizes the reversion loss by guaranteeing a sufficient non-overlapping period of local clocks using a tri-state local clock driver adapting the schmitt trigger. Comparison results using a 0.13-um CMOS process technology indicate that the proposed charge pump achieves up to 49.1% reduction on power consumption under no loading current condition as compared to conventional charge pump. They also indicate that the charge pump provides 19.0% reduction on power consumption under the maximum loading current condition.

Measurement of In-plane Piezoelectric Charge Constant of Electro-Active Paper (Electro-Active Paper의 면내압전상수 측정)

  • Li, Yuanxie;Yun, Gyu-Young;Kim, Heung-Soo;Kim, Jae-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.943-946
    • /
    • 2007
  • In-plane piezoelectric charge constant of Electro-Active paper (EAPap) was investigated based on direct and converse piezoelectric effects. EAPap samples were made with cellulose film with very thin gold electrode coated on both sides of the film. To characterize direct piezoelectricity of EAPap, induced charge was measured when mechanical stress was applied to EAPap. In-plane piezoelectric charge constant was extracted from the relation between induced charge and applied in-plane normal stress. To investigate converse piezoelectricity, induced in-plane strain was measured when electric field was applied to EAPap. Piezoelectric charge constant was also extracted from the relation of induced in-plane strain and applied electric field. Piezoelectric charge constants obtained from direct and converse piezoelectricity are 31 pC/N and 178 x 10-12m/V for 45 degree sample, respectively. Measured piezoelectric charge constants of EAPap provide promising potential as a piezoelectric material.

  • PDF

Exact analysis for overload of a charge-pump phase-locked loop (Charge-pump 위상 동기 회로의 과부하에 대한 정확한 해석)

  • 최은창;이범철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3069-3085
    • /
    • 1996
  • This paper shows an accurate charge-pump PLL model which considers the wave-form distortion in high speed operation of charge-pump PLL, the leakage current in loop filter, and a physical limit in charge-pump. With proposed model of charge-pump PLL, overload and stability are derived theoretically and the results are compared to the conventional model. Unlike the ideal charge-pump PLL that simplifies calculations, it is possible to analyze the transient-state and the steady-state at the same time with proposed accurate model. Thus, charge-pump over load, in the transient-state and the stead-state of charge-pump, is accuragely analyzed and the results are confirmed with simulation.

  • PDF

A Study on A Spiral Charge for 3 Dimensional Charge Simulation Method (3차원 전하 중첩법용 나선 전하의 특성에 관한 연구)

  • 민석원;박은서;송기현
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.31-36
    • /
    • 2001
  • This paper investigates characteristics of spiral charge for 3 dimensional charge simulation method to calculate electric fields of special conductor bundles with spiral rods in 765kV transmission line. We finds the simulating spiral charge as constant charge density give less potential calculation error than sinusoidal charge falsity. When a spiral rod is simulated as spiral charge, we also knows two spiral charge can simulate spiral rod best.

  • PDF

A Study on ESS Optimal Operation Strategy Using Two Stage Hybrid Optimization (Two Stage Hybrid Optimization을 사용한 ESS 최적 운전 전략에 대한 연구)

  • Gong, Eun-Kyoung;Sohn, Jin-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.833-839
    • /
    • 2018
  • This paper presents an analysis and the methodology of optimal operation strategy of the ESS(Energy Storage System) for reduce electricity charges. Electricity charges consist of a basic charge based on the contract capacity and energy charge according to the power usage. In order to use electrical energy at minimal charge, these two factors are required to be reduced at the same time. QP(Quadratic Programming) is appropriate for minimization of the basic charge and LP(Linear Programmin) is adequate to minimize the energy charge. However, the integer variable have to be introduced for modelling of different charge and discharge efficiency of ESS PCS(Power Conversion System), where MILP(Mixed Integer Linear Programming) can be used. In this case, the extent to which the peak load savings is accomplished should be assumed before the energy charge is minimized. So, to minimize the electricity charge exactly, optimization is sequentially performed in this paper, so-called the Two Stage Hybird optimization, where the extent to which the peak load savings is firstly accomplished through optimization of basic charge and then the optimization of energy charge is performed with different charge and discharge efficiency of ESS PCS. Finally, the proposed method is analyzed quantitatively with other optimization methods.

New Charge Pump for Reducing the Current Mismatch (전류 부정합을 줄인 새로운 전하 펌프)

  • Lee, Jae-Hwan;Jeong, Hang-Geun
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.469-471
    • /
    • 2008
  • The charge pump affects the performance of PLL. In designing the charge pump, we need to consider various issues such as current mismatch, charge sharing, feedthrough, charge injection, and leakage current. This paper propose the new charge pump circuit which is improved in terms of the current match over the existing high-speed charge pump. The simple method used for reducing current mismatch is the technique that uses a cascode in order to increase the output resistance of the charge pump. However the method limits the output voltage range of the charge pump. So the method is hard to apply as the supply voltage is lowered. Thus this paper proposes a new charge pump circuit using an op amp instead of the cascode. And the new charge pump circuit has an excellent current matching characteristics over a wide output range.

  • PDF

Influence of Low Stage Refrigerant Charge Amount on the Performance of Cascade Heat Pump (캐스케이드 열펌프의 저단 사이클 충전량 변화에 따른 성능 특성)

  • Park, Seung Byung;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • In this study, the optimization and performance characteristics of a cascade heat pump system was analyzed with the variation of low stage refrigerant charge amount. The cascade heat pump was designed and constructed with R134a and R410A as the refrigerant for high stage and low stage cycle, respectively. Experiments were conducted by varying the low stage charge amount and the performance characteristics of the cascade heat pump were studied. The refrigerant charge amount of the low stage cycle was varied between the ranges of -15% and +10% of the optimum charge amount. The performance variation experienced in the cascade heat pump due to the variation of refrigerant charge amount shows greater effect in the undercharge regions than the overcharge regions. COP reduction in the undercharge region is larger than the decrease in the overcharge region. Some cycle variation such as power consumption and cycle pressure according to low stage refrigerant charge amount showed different trends comparing with those according to high stage refrrgerant charge amount. Therefore, the optimum charge amount of the cascade heat pump should be determined based on the experimental data obtained by the variation of high and low stage refrigerant charge amount.

The design of a charge pump for the high speed operation of PLL circuits (High speed에 필요한 PLL charge pump 회로 설계 및 세부적인 성능 평가)

  • 신용석;윤재석;허창우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.2
    • /
    • pp.267-273
    • /
    • 1998
  • In this paper, we designed a charge pump with a differential current switching structure and it was made of a MESFET with high speed switching Property compared with CMOSFETs. The charge pump with a differential current switching structure is analyzed about operating property of circuit in high frequency band. Also we propose a method on it's characteristics estimation. The designed circuit is simulated by HSPICE simulator, and in view of the results we think that the charge pump of this study can be used in circuits of 1 GHZ frequency band grade.

  • PDF