• Title/Summary/Keyword: Capacitive type sensor

Search Result 104, Processing Time 0.02 seconds

A Study on the Analysis of 5-DOF Axis of Rotation Error in Low Speed Rotary Stage (저속 회전 스테이지의 5자유도 회전축 오차 분석에 관한 연구)

  • Han, Chang-Soo;Kim, Jin-Ho;Shin, Dong-Ik;Yun, Deok-Won;Lee, Yung-Gi;Lee, Sang-Moo;Nam, Gyung-Tai
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.23-27
    • /
    • 2007
  • Rotary stages in semiconductor, display industry and many other fields require challenging accuracy to perform their functions properly. Especially, Axis of rotation error on rotary system is significant; such as the spindle error motion of the aligner, wire bonder and inspector machine which result in the poor quality products. To evaluate and improve the performance of such precision rotary stage, undesired movements on the other 5 degrees of freedom of the rotary stage must be measured and analyzed. In this paper, we have measured the three translations and two tilt motions of the worm gear type spindle with high precision capacitive sensors. To obtain the radial error motion, we have used Donaldson's reversal technique. And the axial components of the spindle tilt error motion can be obtained accurately from the axial direction outputs of sensors by Estler face motion reversal technique. Further more we have designed and developed the sensor mounting jig with standard cylinder for reversal method.

  • PDF

Fabrication and Characteristics of FET-type Pressure Sensor Using Piezoelectric PZT Thin Film (압전체 PZT 박막을 이용한 FET형 압력 센서의 제작과 그 특성)

  • Kim, Young-Jin;Lee, Young-Chul;Kwon, Dae-Hyuk;Sohn, Byung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.173-179
    • /
    • 2001
  • The currently used semiconductor pressure sensors are piezoresistive and capacitive type. Especially, semiconductor micro pressure sensors have a great deal of attention because of their small size. However, its fabrication processes are difficult, so that its yield is poor. For the purpose of resolving the drawbacks of the existing silicon pressure sensors, we demonstrate a new type of pressure sensor using PSFET(pressure sensitive field effect transistor) and investigate its operational characteristics. We used PZT(Pb(Zr,Ti)$O_3$) as a pressure sensing material. PZT thin films were deposited on a gate oxide of MOSFET by an rf-magnetron sputtering method. To abtain the stable phase, perovskite structure, furnace annealing technique have been employed in PbO ambient. The sensitivity of the PSFET was 0.38 mV/mmHg.

  • PDF

Development of Humidity Sensor Based on Ceramic/Metal Halide Composite Films for Non-Contact Biological Signal Monitoring Applications (비접촉 생체신호 모니터링 응용을 위한 세라믹/메탈 할라이드 복합막 기반 습도센서 개발)

  • Park, Tae-Ung;Kim, Ik-Soo;Kim, Min-Ji;Park, Chulhwan;Seo, Eui-kyoung;Oh, Jong-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.4
    • /
    • pp.412-417
    • /
    • 2022
  • Capacitive-type humidity sensors with a high sensitivity and fast response/recovery times have attracted a great attention in non-contact respiration biological signal monitoring applications. However, complicated fabrication processes involving high-temperature heat treatment for the hygroscopic film is essential in the conventional ceramic-based humidity sensors. In this study, a non-toxic ceramic/metal halide (BaTiO3(BT)/NaCl) humidity sensor was prepared at room temperature using a solvent-free aerosol deposition process (AD) without any additional process. Currently prepared BT/NaCl humidity sensor shows an excellent sensitivity (245 pF/RH%) and superior response/recovery times (3s/4s) due to the NaCl ionization effect resulting in an immense interfacial polarization. Furthermore, the non-contact respiration signal variation using the BT/NaCl sensor was determined to be over 700% by maintaining the distance of 20 cm between the individual and the sensor. Through the AD-fabricated sensor in this study, we expect to develop a non-contact biological signal monitoring system that can be applied to various fields such as respiratory disease detection and management, infant respiratory signal observation, and touchless skin moisture sensing button.

A Study on the ECU for Controlling One Cylinder Motorcycle Engine (단기통 모터사이클 엔진 제어용 ECU에 관한 연구)

  • Jung, Tae-Gyun;Chae, Jae-Ou
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.13-20
    • /
    • 2005
  • The most typical fuel control devices of motorcycle engines have carburetors, they are simple in structure and reliable in work. Most of the motorcycle engines have used carburetors in the fuel system, but the fuel economy and the emissions of those engines are bad when we compared with automobile engines. According to stricter emission regulations and higher requirements for fuel economy, the application of the carburetor on the motorcycle engines would be limited. In this paper, we studied about the ECU of motorcycle engine controled by indirect method. A new engine system was designed and experiments were carried out. The experimental results for both carburetor type and ECU type were compared. Maximum torque of $1.053kg{\cdot}m$ at 6500rpm was measured. The engine torque controled using ECU was increased by $10\%$ compared with the carburetor type.

Study of Output Characteristics of Pressure T/D using Piezo Capacitor Type (Piezo-Capacitor방식 입력 Transducer와 출력특성 고찰)

  • Lee, Seong-Jae;Yoo, Byung-Ki
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.245-246
    • /
    • 2009
  • 정전용량형 후막 스트레인 게이지(piezocapacitive thick film strain gage)는 세라믹 ($Al_2O_3$)을 주 원료로 하는 지지대(약 5mm)와 다이어프램(약 $300{\mu}m$) 그리고 가드 링으로 구성된다. 전극 판은 도전성 페이스트를 이용하여 지지대와 다이어프램에 형성되었으며 극판 사이에는 유전체 메이스트를 사용하여 스크린 인쇄로 후막을 형성하였다. 극판 사이의 가드 링 두께는 약 $30{\mu}m$정도로 다이어프램의 변위 최대값을 유지시키는 데 필요한 간격이다. 따라서 정전용랑형 후막 스트레인 게이지는 지지대를 중심으로 다이어프램에 압력 (0.5~1.0bar)이 인가될 때 변위를 발생시키면서 커패시터 값이 압력의 크기에 따라 비례 특성을 가지고 변화하는 것을 이용한 것이다. 압력이 없을때 초기값은 35pF~40pF 정도이고 정격압력의 최대치를 인가시켰을 때 약 55pF~55p를 나타내었다.

  • PDF

High frequency partial discharge measurement by metal foil electrode (박전극을 이용한 고주파 부분방전 측정 연구)

  • Kim, C.S.;Shin, D.S.;Lee, C.Y.;Kim, J.N.;Baek, J.H.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1081-1083
    • /
    • 1999
  • The capacitive coupling technique has been used as conventional method for PD detection on the power cable line. Recently, however PD measurement using by high frequency is known to have an excellent sensitivity comparison with low frequency on-site. In this paper, the high frequency characteristic of two type of metal foil sensor was studied and the technique was proved to be more effective diagnostic method than conventional method for qualification of EHV cable and accessories.

  • PDF

Multiphase Homodyne Laser Interferometer with Four Bucket (Four-bucket 알고리즘을 이용한 레이저 간섭계)

  • Park, Yoon-Chang;Jeong, Kyung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.10
    • /
    • pp.203-208
    • /
    • 1999
  • By tilting the reference mirror of Twynman-Green interferometer having a reference mirror and a moving mirror, firinge pattern composed of bright and dark parallel lines can be obtained and the fringe pattern is shifted according to the displacement of the mowing mirror. Several studies are executed for displacement measurement by detecting the intensity of the fringe with photo-diodes having small detecting area. In this study, to improve the sensitivity and robustness, the intensity of fringe is detected by using a large-area quadratic photo-diode masked with a grating panel having four kinds of binary grating having phase-difference of 0, {\pi}$/4, {\pi}$/2, 3 {\pi}$/4. The phase of the fringe is calculated with a simple 4-buckets algorithm. A experimental result shows that standard deviation of 5.653 nm is obtained comparing with a capacitive type gap sensor having nearly 1 nm accuracy.

  • PDF

A Study on Touchless Panel based Interactive Contents Service using IrDA Matrix

  • Lee, Minwoo;Lee, Dongwoo;Kim, Daehyeon;Ann, Myungsuk;Lee, Junghoon;Lee, Seungyoun;Cho, Juphil;Shin, Jaekwon;Cha, Jaesang
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.73-78
    • /
    • 2015
  • Touch panel is mainly applied to pressure type touch panel but it occur a low recognition rate and error during long-term use. So, it is partly applied to capacitive touch panel to compensate for these problems but it also can occur a same problems via pollutions. Touch technology has developed a various method but it is not used because of high costs and difficult installation process. So, in this paper, we proposed an input method of touchless panel using IrDA matrix. This method is conducted using an IrDA Matrix composed of depth sensor. It is possible to offer a various contents for multi user. The proposed technology need a development of a high sensitivity sensing method and high-speed processing method of position information for Seamless operation control. And, it is required high-precision drive technology. Also, we proposed a Seamless user recognition for interactive contents service through a touchless panel using IrDA matrix.

The Micro Pirani Gauge with Low Noise CDS-CTIA for In-Situ Vacuum Monitoring

  • Kim, Gyungtae;Seok, Changho;Kim, Taehyun;Park, Jae Hong;Kim, Heeyeoun;Ko, Hyoungho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.6
    • /
    • pp.733-740
    • /
    • 2014
  • A resistive micro Pirani gauge using amorphous silicon (a-Si) thin membrane is proposed. The proposed Pirani gauge can be easily integrated with the other process-compatible membrane-type sensors, and can be applicable for in-situ vacuum monitoring inside the vacuum package without an additional process. The vacuum level is measured by the resistance changes of the membrane using the low noise correlated double sampling (CDS) capacitive trans-impedance amplifier (CTIA). The measured vacuum range of the Pirani gauge is 0.1 to 10 Torr. The sensitivity and non-linearity are measured to be 78 mV / Torr and 0.5% in the pressure range of 0.1 to 10 Torr. The output noise level is measured to be $268{\mu}V_{rms}$ in 0.5 Hz to 50 Hz, which is 41.2% smaller than conventional CTIA.

Nano and micro structures for label-free detection of biomolecules

  • Eom, Kil-Ho;Kwon, Tae-Yun;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.403-420
    • /
    • 2010
  • Nano and micro structure-based biosensors are promising tool for label-free detection of biomolecular interactions with great accuracy. This review gives a brief survey on nano and micro platforms to sense a variety of analytes such as DNA, proteins and viruses. Among incredible nano and micro structure for bio-analytical applications, the scope of this paper will be limited to micro and nano resonators and nanowire field-effect transistors. Nanomechanical motion of the resonators transducers biological information to readable signals. They are commonly combined with an optical, capacitive or piezo-resistive detection systems. Binding of target molecule to the modified surface of nanowire modulates the current of the nanowire through electrical field-effect. Both detection methods have advantages of label-free, real-time and high sensitive detection. These structures can be extended to fabricate array-type sensors for multiplexed detection and high-throughput analysis. The biosensors based on these structures will be applied to lab-on-a-chip platforms and point-of-care diagnostics. Basic concepts including detection mechanisms and trends in their fields will be covered in this review.