• 제목/요약/키워드: Cable bridge

검색결과 750건 처리시간 0.033초

강합성 단면을 가진 사장교의 와류진동 발생 예측 (Prediction of Vortex-induced Vibration of the Cable-Stayed Bridge with Steel Composite Deck)

  • 조재영;조영래;이학은
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2007년도 정기총회 및 학술발표대회
    • /
    • pp.449-453
    • /
    • 2007
  • After over a century of effort by researchers and engineers, the problem of bluff body flow, in particular vortex shedding frequency, remains almost entirely in the empirical, descriptive realm of knowledge. Computational methods have been systematically applied for vortex-induced vibrations of the cable-stayed bridge with steel composite deck by unsteady wind loadings due to vortex-shedding. The focus of this paper is to predict the vortex-induced vibration of the cable-stayed bridge with steel composite deck based computational fluid dynamics(CFD).

  • PDF

지중송전계통에서 XLPE케이블의 교량첨가시 모델수립 및 뇌과전압 해석 (Lightning Overvoltage Analysis and Model Establishment of XLPE Cable Underneath a Bridge on Underground Power Cable Systems)

  • 김철호;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2243-2244
    • /
    • 2008
  • In this paper, XLPE cable underneath a bridge is modelled using EMTP/ATPDraw. Bridge section is also modelled by mutually coupled parallel conductor with XLPE cable. This paper is analysed the overvoltge by structure change of bridge section when the lightning occurs on the system.

  • PDF

Construction stage analysis of three-dimensional cable-stayed bridges

  • Atmaca, Barbaros;Ates, Sevket
    • Steel and Composite Structures
    • /
    • 제12권5호
    • /
    • pp.413-426
    • /
    • 2012
  • In this paper, nonlinear static analysis of three-dimensional cable stayed bridges is performed for the time dependent materials properties such as creep, shrinkage and aging of concrete and relaxation of cable. Manavgat Cable-Stayed Bridge is selected as an application. The bridge located in Antalya, Turkey, was constructed with balanced cantilever construction method. Total length of the bridge is 202 m. The bridge consists of one $\ddot{e}$ shape steel tower. The tower is at the middle of the bridge span. The construction stages and 3D finite element model of bridge are modeled with SAP2000. Large displacement occurs in these types of bridges so geometric nonlinearity is taken into consideration in the analysis by using P-Delta plus large displacement criterion. The time dependent material strength and geometric variations are included in the analysis. Two different finite element analyses carried out which are evaluated with and without construction stages and results are compared with each other. As a result of these analyses, variation of internal forces such as bending moment, axial forces and shear forces for bridge tower and displacement and bending moment for bridge deck are given with detailed. It is seen that construction stage analysis has a remarkable effect on the structural behavior of the bridge.

Using cable finite elements to analyze parametric vibrations of stay cables in cable-stayed bridges

  • Wu, Qingxiong;Takahashi, Kazuo;Chen, Baochun
    • Structural Engineering and Mechanics
    • /
    • 제23권6호
    • /
    • pp.691-711
    • /
    • 2006
  • This paper uses the finite element method to simultaneously consider the coupled cable-deck vibrations and the parametric vibrations of stay cables in dynamic analysis of a cable-stayed bridge. The stay cables are represented by some cable finite elements, which can consider the parametric vibration of the cables. In addition to modeling stay cables using multiple link cable elements, a procedure for removing the self-weight term of cable element is proposed. A eigenvalue analysis process using dynamic condensation method for sorting out the natural modes of the girder-tower vibrations and the Rayleigh damping considering element damping for damping matrix are also proposed for dynamic analyses of cable-stayed bridges. The possibilities of using cable elements and of using global and local vibrations to evaluate the parametric vibrations of stay cables in a cable-stayed bridge are confirmed, respectively.

사장교 케이블 손상 사나리오에 따른 구조 안전 수준 평가 (Structural Safety Evaluation of Cable Stayed Bridge based on Cable Damage Scenarios)

  • 김가영;서동우
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.105-111
    • /
    • 2018
  • 본 연구는 케이블 시스템의 손상으로 인한 케이블지지 교량의 안전 수준을 평가하여 재난 관리의 활용을 목적으로 한다. 국내에 다양한 형태의 케이블지지 교량(현수교 및 사장교)이 건설되었다. 이러한 교량은 복잡한 구조 요소와 시스템을 가지고 있기 때문에 효율적인 유지 관리가 필요하다. 케이블지지 교량은 종종 인적 또는 자연 재난에 따른 위험을 직면하기도 한다. 2015년 국내 공용중인 사장교에서 번개에 의한 케이블 화재 사고가 발생하였다. 이 사건으로 인해 케이블이 파단이 발생하였고, 교량 붕괴의 위험까지도 고려되었다. 또한 이 사고로 인해 엄청난 사회적 경제적 비용이 요구되었다. 이 사건 이후로 이러한 대형 인프라 시설물에 대한 리스크 기반의 유지관리가 요구되고 있다. 본 연구는 잠재적 인 케이블 피해로 인한 교량의 안전 수준을 평가하기 위하여 수행되었고, 국내의 사장교 1개소를 선정하여 효율적이고 신속한 관리를 위한 의사결정 지원을 목표로 케이블 시스템의 손상 시나리오에 따른 교량 안전 수준을 평가하였다. 사장교의 케이블 손상 시나리오에 따른 안전 수준은 FEM 해석을 통하여 분석되었다.

해상 사장교의 Pipe형 케이블 정착구에 관한 구조해석 (Structural Analysis of a Cable Anchor System for a Cable-Stayed Bridge over the Sea)

  • 공병승;홍남식
    • 한국해양공학회지
    • /
    • 제19권5호
    • /
    • pp.34-42
    • /
    • 2005
  • The cable connection zone of the cable-stayed bridge transfers deal-load, live-load, and second-load to the cables on the structural joint zone of the cables and the main girders are the most critical parts in which big cable tensile forces are generated by those loads. Therefore, it is necessary to thoroughly check the main girder, structurally to secure the required stability. Because of the heavy tensile force of cables linked in the connection zone of the cable-stayed bridge, locally concentrated stress, as well as the dispersion of stress, occurs in the structurally contacted point of cable and main girder thus, we need to make a thorough investigation through a detailed structural analysis. Directly delivering the tensile force to the connection zone of the cable, the consequently big effect in the tensile force fluctuation caused by the live-load will make it necessary to review the fatigue strength. As the connection zone of the cable is designed to resist the tensile force of the cable, which is applied to a connecting section as a concentrated force, thick plates are used. These plates are frequently made of welded structure, thus, the investigation of the welding workability is inevitable.

An evaluation system for determining the stress redistribution of a steel cable-stayed bridge due to cable stress relaxation at various temperatures

  • Tien-Thang Hong;Duc-Kien Thai;Seung-Eock Kim
    • Steel and Composite Structures
    • /
    • 제46권6호
    • /
    • pp.805-821
    • /
    • 2023
  • This study developed an evaluation system to explore the effect of the environmental temperature on the stress redistribution produced by cable stress relaxation of structural members in a steel cable-stayed bridge. The generalized Maxwell model is used to estimate stress relaxation at different temperatures. The environmental temperature is represented using the thermal coefficients and temperature loads. The fmincon optimization function is used to determine the set of stress relaxation parameters at different temperatures for all cables. The ABAQUS software is employed to investigate the stress redistribution of the steel cable-stayed bridge caused by the cable stress relaxation and the environmental temperature. All of these steps are set up as an evaluation system to save time and ensure the accuracy of the study results. The developed evaluation system is then employed to investigate the effect of environmental temperature and cable type on stress redistribution. These studies' findings show that as environmental temperatures increased up to 40 ℃, the redistribution rate increased by up to 34.9% in some girders. The results also show that the cable type with low relaxation rates should be used in high environmental temperature areas to minimize the effect of cable stress relaxation.

Passive control system for seismic protection of a multi-tower cable-stayed bridge

  • Geng, Fangfang;Ding, Youliang;Song, Jianyong;Li, Wanheng;Li, Aiqun
    • Earthquakes and Structures
    • /
    • 제6권5호
    • /
    • pp.495-514
    • /
    • 2014
  • The performance of passive control system for the seismic protection of a multi-tower cable-stayed bridge with the application of partially longitudinal constraint system is investigated. The seismic responses of the Jiashao Bridge, a six-tower cable-stayed bridge using the partially longitudinal constraint system are studied under real earthquake ground motions. The effects of the passive control devices including the viscous fluid dampers and elastic cables on the seismic responses of the bridge are examined by taking different values of parameters of the devices. Further, the optimization design principle of passive control system using viscous fluid dampers is presented to determine the optimized parameters of the viscous fluid dampers. The results of the investigations show that the control objective of the multi-tower cable-stayed bridge with the partially longitudinal constraint system is to reduce the base shears and moments of bridge towers longitudinally restricted with the bridge deck. The viscous fluid dampers are found to be more effective than elastic cables in controlling the seismic responses. The optimized parameters for the viscous fluid dampers are determined following the principle that the peak displacement at the end of bridge deck reaches to the maximum value, which can yield maximum reductions in the base shears and moments of bridge towers longitudinally restricted with the bridge deck, with slight increases in the base shears and moments of bridge towers longitudinally unrestricted with the bridge deck.

진동법을 이용한 사장교의 시공 중 장력 평가 (Evaluation of Cable Tension Forces Using Vibration Method for a Cable-stayed Bridge under Construction)

  • 조수진;윤정방;심성한
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.38-44
    • /
    • 2014
  • When a cable-stayed bridge is under construction, the cable tension that changes according to the construction phase is the index indicating the proper construction management. In this study, the vibration method using the least-square estimation has been implemented to monitor changing tensions of two multi-strand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea with a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions of two cables are measured before and after the tensioning and 5 days later (i.e., after finishing the tensioning of all cables). The accuracy of the estimated tensions by the vibration method has been improved by employing proper effective lengths of the cables. The measured tensions are compared with the result of the lift-off tests and design tensions. The vibration method shows very good performance in monitoring the changing tensions according to the construction phase with minimal error.

마찰복원형 지진격리장치가 설치된 케이블교량의 성능 기반 내진설계법 개선(II-내진설계 절차 제안) (Improvement of the Performance Based Seismic Design Method of Cable Supported Bridges with Resilient-Friction Base Isolation Systems (II-Proposal for the Seismic Design Procedure))

  • 길흥배;박선규;한경봉;윤완석
    • 한국지진공학회논문집
    • /
    • 제24권4호
    • /
    • pp.169-178
    • /
    • 2020
  • In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the "Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges" is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.