• Title/Summary/Keyword: Ca-test

Search Result 1,333, Processing Time 0.024 seconds

Nutritional Evaluation of Some Tropical Crop Residues: In Vitro Organic Matter, Neutral Detergent Fibre, True Dry Matter Digestibility and Metabolizable Energy Using the Hohenheim Gas Test

  • Aregheore, E.M.;Ikhatua, U.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.5
    • /
    • pp.747-751
    • /
    • 1999
  • The Hohenheim in vitro gas test was used to assess the nutritional value of some crop residues of known in vivo digestibility. The crop residues are groundnut shells (GNS) corn cobs (CC); cassava peels (CaP); unripe and ripe plantain peels (UPP, RPP) and citrus pulp/peels (CPP). Compared to other crop residues, crude protein (CP) content of CC was low. Except for CaP and CPP that had low neutral detergent fibre (NDF) and acid detergent fibre (ADF), other residues contained a high amount of cell wall constituents. Net gas production was significantly different among the crop residues (p<0.05). Gas production was highest in CPP followed by CaP. CC, UPP and RPP have the same volume of net gas production, while the least net gas production was in GNS. True dry matter (TDM) digestibility was significantly different (p<0.05) among the residues. GNS was the least in TDM digestibility. CaP, UPP and RPP had similar TDM digestibility values, while the highest TDM digestibility was obtained in CPP. OM digestibility was different among the residues (p<0.05). CaP and CPP had the same ME value while CC, UPP and RPP had close ME values and GNS the least in ME (p<0.05). The potential extent (b) and rate (c) of gas production were statistical different among the residues (p<0.05). The Hohenheim gas test gave high in vitro organic matter (OM) digestibility for CC, CaP, UPP and RPP and CPP. Fermentable carbohydrates and probably available nitrogen in the crop residues influenced net gas production. The results showed that crop residues besides, providing bulk are also a source of energy and fermentable products which could be used in ruminant livestock production in the tropics.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

The Examination of Mortar Durability by Microbial Biomineralization (미생물의 생체광물형성작용에 따른 모르타르 내구성 검토)

  • Kim, Sung-Tae;Chun, Woo-Young;Kim, Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.525-526
    • /
    • 2009
  • On this paper we induce calcite($CaCO_3$) precipitation using microbial biomineralization of the Sporosarcina pasteurii and evaluate required performance evaluation by adjusting it to mortar. As a result carbonation normal mortar test piece(C3S-W) and mortar test piece(C3S-S.p) mixed with Sporosarcina pasteurii, reaction of C3S-S.p was late than C3S-W. Also, in the case of carbonation experiment of C3S-S.p curing in the Urea-CaCl2 aqueous solution(Medium) during 28days and durability of the C3S-W, durability of the mortar test piece(C3S-S.p) mixed with Sporosarcina pasteurii become higher than normal mortar test piece(C3S-W).

  • PDF

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Effects of Korean Computer-Based Cognitive Rehabilitation Program(CoTras) on Frontal-Executive Functions in Patients with Traumatic Brain Injury (한국형 전산화 인지재활프로그램(CoTras)이 외상성 뇌손상 환자의 전두엽-집행기능에 미치는 영향)

  • Han, Seung-Hyup;Jo, Eun-Ju;Noh, Dong-hee;Kam, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3344-3352
    • /
    • 2015
  • The purpose of this study is to investigate the effects of Korean computer-based cognitive rehabilitation program (CoTras) on frontal-executive functions in patients with traumatic brain injury (TBI). This study was performed at C hospital in Changwon, Gyeongsangnam-do, Korea from August 2013 to March 2014. Ten patients with TBI were randomly divided into two groups. The experimental group had been given CoTras once a day, five times a week for four weeks, whereas the control group had performed self-cognitive training under the same conditions. To verify the effect of intervention, the following executive function measures were used: Korean Montreal Cognitive Assessment (K-MoCA), Executive Clock Drawing Test (ECDT), Trail Making Test (TMT), Rey-Complex Figure Test (RCFT). Intervention group showed significant increase in K-MoCA, TMT, RCFT-delayed recall (p<.05). However, control group showed no significant change in any test. There was significant difference of changed scores (post test-pre test) between two groups in K-MoCA, TMT and RCFT-delayed recall (p<.05). This study showed that CoTras is effective to improve frontal-executive functions in patients with traumatic brain injury.

A Case Study en the Effect of Ca Intake on Depression and Anxiety (칼슘섭취가 60세 전후 성인의 우울 및 불안 성향에 미치는 영향에 관한 사례연구)

  • 박귀선;이경애
    • Journal of Nutrition and Health
    • /
    • v.35 no.1
    • /
    • pp.45-52
    • /
    • 2002
  • This study was to investigate 1) the correlation of serum Ca, with depression and anxiety ; and 2) the effect of Ca intake on those symptoms. The subjects were three females and two males who were 53-66 years old with the severe subjective symptoms of depression and anxiety. They have taken more than twice Ca of RDA(recommended dietary allowances for Koreans) daily for 6 months(dietary treatment). The prestudy Ca intake of the subjects was low: 60% of RDA for Koreans. Their serum Ca concentration was also low: 6.67 $\pm$ 0.15mg/d1 before the dietary treatment. They expressed severs depression and anxiety, with high self scores in a psychological test. Their serum Ca concentration increased to 8.32 $\pm$ 0.17mg/dl after six months of dietary treatment, while the symptoms of depression and anxiety decreased significantly after two months and nearly disappeared after six months. This result seemed to be an effect of the dietary high Ca intake. Serum Ca and the psychological states of depression and anxiety correlated negatively, and the coefficients of determination were high in the results of linear regression analysis of depression and anxiety by serum Ca. Therefore the serum Ca concentration could be a good marker to predict depression or anxiety relatively well. The continuous high Ca intake could decrease the probability of developing depression or anxiety and mitigate their symptoms because serum Ca concentration increased, while the state of depression and anxiety decreased with the increased Ca intake.

Clinical Significance of Combined Detection of Serum Tumor Markers in Diagnosis of Patients with Ovarian Cancer

  • Bian, Jing;Li, Bo;Kou, Xian-Juan;Liu, Tian-Zhou;Ming, Liang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6241-6243
    • /
    • 2013
  • Objective: To explore the predictive value of tumor markers, including cancer antigen 72-4 (CA72-4), cancer antigen 15-3 (CA15-3) and cancer antigen 125 (CA125), in single or combined detection, for the diagnosis of ovarian cancer. Methods: 120 patients diagnosed with ovarian cancer from August 2011 to March 2013 and 80 patients diagnosed with benign ovarian tumors were enrolled in this test, along with 50 health examination women randomly selected from the database as controls. Serum levels of CA72-4, CA15-3 and CA125 in this study were determined by electrochemiluminescence (ECL). Results: Serum levels of CA72-4, CA15-3 and CA125 in ovarian cancer were higher than those in healthy group and benign group (P<0.01).The sensitivity of combined detection of those three tumor markers for diagnosis of ovarian cancer was obviously higher than with single detection with each marker (P<0.01). Conclusions: CA72-4, CA15-3 and CA125 could be a good combination in the diagnosis of ovarian cancer. Patients whose tumor markers continue to increase should be highly suspected of malignancy.

Effects of Alloying Elements on the Corrosion Layer Formation of Pb-Grid/Active Materials Interface (Pb 기판/활물질 계면의 부식층형성에 미치는 합금원소영향)

  • Oh, Se-Woong;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.5
    • /
    • pp.225-233
    • /
    • 2007
  • Effects of alloying elements on the corrosion layer formation of Pb-grid/active materials interface has been researched for improvement of corrosion resistance of Pb-Ca alloy. For this research, various amounts of alloying elements such as Sn, Ag and Ba were added to the Pb-Ca alloys and investigated their corrosion behaviors. Batteries fabricated by using these alloys as cathode grids were subjected to life cycle test. Overcharge life cycle test was carried out at $75^{\circ}C$, 4.5 A, for 110 hrs. with KS standard (KSC 8504). And then, after keeping the battery with open circuit state for 48 hr, discharge was carried out at 300A for 30 sec. Corrosion morphology and interface between Pb-grid and active materials were investigated by using ICP, SEM, WDX, and LPM. Corrosion layer of Pb-Ca alloy got thicken with increasing Ca content. For Pb-Ca-Sn alloy, thickness of corrosion layer decreased as Sn and Ag content increased gradually. In case of Pb-Ca-Sn-Ba alloy, thickness of corrosion layer decreased up to 0.02 wt% Ba addition, whereas, it was not changed in case of above 0.02 wt% Ba addition.

Genetic association tests when a nuisance parameter is not identifiable under no association

  • Kim, Wonkuk;Kim, Yeong-Hwa
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.6
    • /
    • pp.663-671
    • /
    • 2017
  • Some genetic association tests include an unidentifiable nuisance parameter under the null hypothesis of no association. When the mode of inheritance (MOI) is not specified in a case-control design, the Cochran-Armitage (CA) trend test contains an unidentifiable nuisance parameter. The transmission disequilibrium test (TDT) in a family-based association study that includes the unaffected also contains an unidentifiable nuisance parameter. The hypothesis tests that include an unidentifiable nuisance parameter are typically performed by taking a supremum of the CA tests or TDT over reasonable values of the parameter. The p-values of the supremum test statistics cannot be obtained by a normal or chi-square distribution. A common method is to use a Davies's upper bound of the p-value instead of an exact asymptotic p-value. In this paper, we provide a unified sine-cosine process expression of the CA trend test that does not specify the MOI and the TDT that includes the unaffected. We also present a closed form expression of the exact asymptotic formulas to calculate the p-values of the supremum tests when the score function can be written as a linear form in an unidentifiable parameter. We illustrate how to use the derived formulas using a pharmacogenetics case-control dataset and an attention deficit hyperactivity disorder family-based example.

Synthesis of Symmetric 1-D 5-neighborhood CA using Krylov Matrix (Krylov 행렬을 이용한 대칭 1차원 5-이웃 CA의 합성)

  • Cho, Sung-Jin;Kim, Han-Doo;Choi, Un-Sook;Kang, Sung-Won
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.6
    • /
    • pp.1105-1112
    • /
    • 2020
  • One-dimensional 3-neighborhood Cellular Automata (CA)-based pseudo-random number generators are widely applied in generating test patterns to evaluate system performance and generating key sequence generators in cryptographic systems. In this paper, in order to design a CA-based key sequence generator that can generate more complex and confusing sequences, we study a one-dimensional symmetric 5-neighborhood CA that expands to five neighbors affecting the state transition of each cell. In particular, we propose an n-cell one-dimensional symmetric 5-neighborhood CA synthesis algorithm using the algebraic method that uses the Krylov matrix and the one-dimensional 90/150 CA synthesis algorithm proposed by Cho et al. [6].