• Title/Summary/Keyword: C-SCAN

Search Result 784, Processing Time 0.032 seconds

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Delay Fault Test for Interconnection on Boards and SoCs (칩 및 코아간 연결선의 지연 고장 테스트)

  • Yi, Hyun-Bean;Kim, Doo-Young;Han, Ju-Hee;Park, Sung-Ju
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.2
    • /
    • pp.84-92
    • /
    • 2007
  • This paper proposes an interconnect delay fault test (IDFT) solution on boards and SoCs based on IEEE 1149.1 and IEEE P1500. A new IDFT system clock rising edge generator which forces output boundary scan cells to update test data at the rising edge of system clock and input boundary scan cells to capture the test data at the next rising edge of the system clock is introduced. Using this proposed circuit, IDFT for interconnects synchronized to different system clocks in frequency can be achieved efficiently. Moreover, the proposed IDFT technique does not require any modification of the boundary scan cells or the standard TAP controller and simplifies the test procedure and reduces the area overhead.

MnO2 Nanowires Electrodeposited in a Porous Network of Agarose Gel as a Pseudocapacitor Electrode

  • Jin, Sohyun;Ryu, Ilhwan;Lim, Geo;Yim, Sanggyu
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.406-410
    • /
    • 2020
  • Despite a simple preparation of manganese oxide (MnO2) nanowires by electrodeposition, the improvement in specific capacitance (Csp) and voltammetric response of the MnO2 nanowire-based electrodes has been quite limited. This is attributed to the poor electrical conductivity of MnO2 and its dense bulk morphology due to the aggregation of the nanowires. This study investigated the capacitive performance of MnO2 nanowires electrodeposited on agarose thin films. The good ionic conductivity and porous network of the agarose film provided favorable growth conditions for the MnO2 nanowires with suppressed aggregation. A maximum Csp value of 686 F/g measured at a scan rate of 10 mV/s was obtained, which was significantly larger than that of 314 F/g for the agarose-free MnO2 electrode at the same scan rate. The rate capability was also improved. The Csp measured at a high scan rate of 100 mV/s retained 74.0% of the value measured at 10 mV/s, superior to the retention of 71.1% for the agarose-free MnO2 electrode.

A Secure Communication Framework for the Detection System of Network Vulnerability Scan Attacks (네트워크 취약점 검색공격 탐지 시스템을 위한 안전한 통신 프레임워크 설계)

  • You, Il-Sun;Kim, Jong-Eun;Cho, Kyung-San
    • The KIPS Transactions:PartC
    • /
    • v.10C no.1
    • /
    • pp.1-10
    • /
    • 2003
  • In this paper, we propose a secure communication framework for interaction and information sharing between a server and agents in DS-NVSA(Detection System of Network Vulnerability Scan Attacks) proposed in〔1〕. For the scalability and interoperability with other detection systems, we design the proposed IDMEF and IAP that have been drafted by IDWG. We adapt IDMEF and IAP to the proposed framework and provide SKTLS(Symmetric Key based Transport Layer Security Protocol) for the network environment that cannot afford to support public-key infrastructure. Our framework provides the reusability of heterogeneous intrusion detection systems and enables the scope of intrusion detection to be extended. Also it can be used as a framework for ESM(Enterprise Security Management) system.

$^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant (개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔)

  • Zeon, S.K.;Ryu, J.G.;Park, C.K.;Yoo, Y.S.;Jung, D.S.;Lee, J.K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

Analysis of Diffusion Bonded Parts Using Immersed UT Method (수침초음파를 이용한 확산접합부평가)

  • Park, J.C.;Oh, C.S.;Kim, Y.S.;Kim, J.G.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.12 no.3
    • /
    • pp.33-39
    • /
    • 1992
  • This paper presents a summary of the immersion ultrasonic test to analyze the quality of diffusion bonding parts. The most important property of diffusion bonding parts is bonding strength, and that can be obtained by shear test. By comparing among data obtained by ultrasonic test(C-Scan) and those by shear test (bonding strength), these data are shown to be in good relation. Therefore ultrasonic C-Scan test result can be used successfully in quantitative quality control for diffusion bonded parts.

  • PDF

Partial Scan Performance Evaluation of Iterative Method of Testability Measurement(ITEM) (시험성 분석 기법(ITEM)의 부분 스캔 성능 평가)

  • 김형국;이재훈;민형복
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.35C no.11
    • /
    • pp.11-20
    • /
    • 1998
  • Testability analysis computes controllabilities and observabilities of all lines of a circuit and then evaluates fault coverage. The values of controllability and observability as well as fault coverage produced by testability analysis are used for applications of testability analysis. ITEM was evaluated as a fault coverage tool. But the values of controllability and observability at all lines of circuits must be estimated as a performance measure of testability tools for another application such as partial scan. In this paper, partial scan method based on sensitivity analysis which estimates relative improvement of detectability of circuits after scanning a flip-flop is used for performance evaluation of ITEM. Performance of ITEM, with respect to testability values on each net, has been measured by comparing ITEM and STAFAN. Partial scan performance achieved by ITEM is very similar to that of STAFAN, but ITEM takes less CPU time. Therefore ITEM is very efficient for partial scan application because ITEM runs faster for very large circuits in which execution time is critical.

  • PDF

Binary Connected-component Labeling with Block-based Labels and a Pixel-based Scan Mask (블록기반 라벨과 화소기반 스캔마스크를 이용한 이진 연결요소 라벨링)

  • Kim, Kyoil
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.287-294
    • /
    • 2013
  • Binary connected-component labeling is widely used in the fields of the image processing and the computer vision. Many kinds of labeling techniques have been developed, and two-scan is known as the fastest method among them. Traditionally pixel-based scan masks have been used for the first stage of the two-scan. Recently, block-based labeling techniques were introduced by C. Grana et. al. and L. He et. al. They are faster than pixel-based labeling methods. In this paper, we propose a new binary connected-component labeling technique with block-based labels and a pixel-based scan mask. The experimental results with various images show that the proposed method is faster than the He's which is known as the fastest method currently. The amount of performance enhancement is averagely from 3.9% to 22.4% according to the sort of the images.

The Significance of $^{99m}Technetium$ Dimercaptosuccinic Acid(DMSA) Scan as a Substitute for Voiding Cystourethrography(VCUG) in Evaluating Children with first Febrile Urinary Tract Infection (생애 첫 발열성 요로 감염 환아에 대한 평가에서 배뇨성 방광 요도 조영술을 대체하기 위한 검사로서 $^{99m}technetium$ dimercaptosuccinic acid(DMSA) scan의 의의)

  • Han, Seung-Beom;Ko, Yong-Min;Lee, Sue-Young;Jeong, Dae-Chul;Kang, Jin-Han;Lee, Kyung-Yeon;Uhm, Mee-Ryung;Kim, Woong-Heum;Kim, Jung-Sue
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.220-228
    • /
    • 2007
  • Purpose : We studied the value of clinical signs, laboratory findings and $^{99m}technetium$ dime-rcaptosuccinic acid(DMSA) scan in predicting the presence of vesicoureteral reflux(VUR) in children with first febrile urinary tract infection(UTI). Methods : A retrospective analysis of 84 hospitalized children with first febrile UTI was performed. They underwent DMSA scan and voiding cystourethrography(VCUG) during the acute phase, and were divided into three groups according to the results of the VCUG: absence of VUR, mild(grade I-II) and severe VUR(grade III-V). We studied the relation of VUR to age, gender, fever duration, causative organism, white blood cell count, serum C-reactive protein and result of DMSA scan. Results : Among 84 patients, 6 had mild and 17 had severe VUR. Thirty-eight had abnormal DMSA scan. results Patients with VUR were older than those without VUR(P<0.01). There was a lower probability of infection with Escherichia coli in patients with severe VUR than in those with mild and absent VUR(P<0.01). An abnormal DMSA scan correlated with the presence and severity of VUR(P<0.05). Severe VUR was present in 10.9% of patients with normal DMSA scan. The sensitivity, specificity, positive and negative predictive values of the DMSA scan in predicting the presence of VUR were 69.6%, 63.9%, 42.1%, and 84.8%, respectively. Conclusion : An abnormal DMSA scan correlated to the presence and severity of VUR, but the sensitivity, specificity and positive predictive value of the DMSA scan were low. There-fore, patient with an abnormal DMSA scan requires a VCUG. In order to prevent missing the 10.9% of patients with severe VUR but normal DMSA scans, a VCUG should be performed in patient with normal DMSA scan.

  • PDF