• Title/Summary/Keyword: Burn-In Test

Search Result 203, Processing Time 0.028 seconds

A Study on the Status of Injuries Experience and Prevention in Dental Office (진료실 안전사고에 의한 치과위생사의 외상 경험 실태 및 예방 실천에 관한 연구)

  • Choi, Mi-Hyun;Bae, Hyun-Sook
    • Journal of dental hygiene science
    • /
    • v.15 no.6
    • /
    • pp.845-850
    • /
    • 2015
  • The purpose of this study was to examine the actual state of injuries experience and safety accident prevention in dental hygienists. This study surveyed the actual state of injuries experience caused by apparatus and materials through a self-administered survey of 366 dental hygienists. Statistical analysis was performed using PASW Statistics 18.0. Frequency, chi-square test, t-test, one-way ANOVA were applied in this analysis. The results were as follows: Out of the 307 subjects (83.9%) experienced injuries in the last 6 months, and 294 subjects (80.3%) chose the stab as the most frequent type of injuries experience and it was followed by incised wound, scratch and burn. In relation to the differences in injuries experience depending on general characteristics, there were significant differences depending on the age, career, position, dental treatment (p<0.001) and the education (p<0.01). In relation to the differences in the level of safety accident prevention practice depending on general characteristics, there were significant differences depending on the injuries experience, age (p<0.05) and the types of dental clinics (p<0.01). Therefore, We suggest to establish a systematic process for safety accident prevention in dental clinics and emphasize the importance of prevention through continued safety education be needed.

Relationship between Types of Sociometric Status and KSD Reaction of High Grade Elementary School Students (초등학교 고학년 학생의 사회성측정 지위 유형과 동적학교생활그림검사(KSD)의 관계)

  • Ahn, Ie-Hwan
    • The Korean Journal of Elementary Counseling
    • /
    • v.9 no.1
    • /
    • pp.1-20
    • /
    • 2010
  • This research was carried out to see that to what extent KSD reaction can be related to types of sociometric status, and it was carried out on the basis of an hypothesis that KSD reactions of elementary school students in high grades(4th, 5th, 6th grades) would vary according to gender and 5 types of sociometric status, For that purpose, sociometry which were developed by Ahn Iehwan(2007) and KSD, were implemented with students of 20 classes (5 classes of 4th grade, 5 classes of 5th grade and 10 classes of 6th grade) at an elementary school in A city. Number of students surveyed was 366 and it was not exactly the stratified cluster sampling method. To verify 3 hypotheses, independent samples t-test, one way ANOVA, discriminant analysis were made. As a result, there was statistically significant difference in action factor and characteristics factor among 3 factors of KSD reaction by gender, but there was not statistically significant difference in dynamics factor. The result of one way ANOVA showed there was statistically significant difference in characteristics factor and dynamics factor among female students, but there was not statistically significant difference in action factor. Therefore, it was understood that characteristics factor of KSD reaction was closely related to gender difference and types of sociometric status. From the result of this research, it was considered necessary to review KSD scoring system suggested by 田中志帆(2009). And lastly, it was observed that KSD reaction was not effective in evaluating sociometry, and a new approach to the projective drawing test was suggested as a supplementary method for sociometry.

  • PDF

A Review of Combination Effects and Adverse Effects of Yerba Mate (Ilex paraguariensis) on the Treatment of Obesity (비만치료를 목적으로 마테(Yerba Mate, Ilex paraguariensis)를 함유한 복합투여물의 효과 및 부작용에 대한 고찰)

  • Ahn, Jae Hyun;Lee, Min Ho;Lee, Seung Hoon;Choi, Do Young;Lee, Jae Dong
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.135-150
    • /
    • 2016
  • Objectives : The aim of this study is to review the combination effects and adverse effects of Yerba Mate (Ilex paraguariensis) on the treatment of obesity. Methods : Four databases were searched, including Pubmed, National assembly library, RISS4u, and NDSL, for studies published before March 31, 2016 using the keywords 'yerba mate', 'Ilex paraguariensis', and those related to 'obesity'. Clinical trials, and both in vivo and in vitro studies were classified according to the following categories: publication year, nationality, types and composition of test compounds, combination effects, adverse effects, and safety. Results : A total of 16 articles (14 clinical trials, one in vivo, one in vitro) were included in the analysis. Combination effects were reported from six YGD (Yerba Mate, Guarana, Damiana, Zotrim), five Meltdown, one Shred-matrix, one DBX (DymaBurn Xtreme), one XSIII research study, and adverse effects were reported from two YGD (Zotrim), four Meltdown, one Shred-matrix and one MetEF research study. YGD and Shred-matrix increased satiety while YGD and MetEF had adverse gastrointestinal effects potentially due to guarana. Meltdown and Shred-matrix increased energy expenditure and fat oxidation and had the adverse effects of increased heart rate and blood pressure due to the thermogenic effect of caffeine and yohimbine. DBX increased resting energy expenditure but no difference was observed in respiratory exchange ratio. XSIII reduced body weight gain and food intake more than each of the extracts did on their own. Conclusion : Taken together, the combination effects and adverse effects differed according to the composition of test compounds and the ratio of ingredients. Multicomponent approaches should be used for treating multifactorial diseases such as obesity. As a general conclusion, there is a place for a combination of herbal components including yerba mate, based on the principle of Kun-Shin-Choa-Sa for the treatment of obesity.

Study of the Density of Smoke and Harmful Gases of Adhesive Indirect Moxibustion (접착식 간접구의 연기 밀도 및 유해가스 발생 확인 연구)

  • Kim, Eun-Jung;Kim, Yu-Jong;Hwang, Ji-Hoo;Cho, Hyun-Seok;Kim, Kyung-Ho;Lee, Seung-Deok;Kim, Kap-Sung
    • The Journal of Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: We measured the density of smoke and harmful gases emitted from burning adhesive indirect moxa. Through the test we aimed to find out if there was an excessive amount of smoke emitted and if it included harmful gases. Methods: 9 types of adhesive indirect moxa were chosen. The buffer layers which do not burn during treatment were removed and 10g of each moxa were made into powder and put into a holder. A smoke density chamber (Smoke Density Chamber FTT. U.K) and Fourier transform infrared spectroscopy (FT-IR I 4001. MIDAC U.S.A.) were used to measure the density of smoke and harmful gases emitted from burning moxa by ISO 5659-2 test. Results: The result of measuring maximum smoke density showed that the regular indirect adhesive moxa (A-F) emitted high density smoke of 172.1-291.4Ds. The smokeless moxas, Seoam moxas, emitted the least amount of 3.4-5.5Ds. Concentrations of 7 typical harmful gases (CO, HCl, HCN, HBr, HF, SO2, NOx) were measured and all of the moxas emitted CO due to incomplete combustion. 4 types of moxa emitted NOx and all smokless moxas emitted NOx. HBr, HCN, HCl, HF, SO2 were not found in any of the moxas. Conclusions: The amount of harmful gases emitted from burning moxa was much lower than short-term exposure standards of chemical and physical factors (Ministry of Labor 2010-44). Further experiments measuring gases from moxa combustion should be done in larger environments similar to normal medical clinics.

Effect of Light Receiving rate on Growth and Quality of Ginseng Cultivated in Plastic House

  • Sang Young Seo;Jong hyeon Cho;Chang Su Kim;Hyo Jin Kim;Min Sil An;Du Hyeon Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2020.12a
    • /
    • pp.62-62
    • /
    • 2020
  • Ginseng is a shade-plant cultivated using shading facilities. However, at too low light levels, root growth is poor, and at high light levels, the destruction of chlorophyll reduces the photosynthesis efficiency due to leaf burn and early fall leaves. The ginseng has a lightsaturation point of 12,000~15,000 lux when grown at 15 to 20℃ and 9,500 lux at 25℃. This study was conducted to select the optimal light intensity of 3-year-old ginseng grown in blue-white film plastic house. The seeds were planted in the blue-white film plastic house with different light receiving rate (March 17, 2020). Between April and September, the average air temperature in the house was 20.4-20.7℃. Average soil temperature was 18.3℃-18.5℃. The chemical properties of the test soil was as follows. The pH level was 7.0-7.4, EC was 0.5-0.6 dS/m, OM was at the levels of 33.6-37.7 g/kg, P2O5 was 513.0-590.8 mg/kg, slightly higher than the allowable 400 mg/kg. The amount of light intensity, illuminance, and solar radiation in the blue-white film house was increased as the light-receiving rate increased and the amount of light intensity was found to be 9-14% compared to the open field, 8-13% illuminance and 9-14% solar irradiation respectively. The photosynthesis rate was the lowest at 3.1 µmolCO2/m2/s in the 9% light blue-white plastic house and 4.2 and 4.0 µmolCO2/m2/s in the 12% and 14% light blue-white plastic house, respectively. These results generally indicate that the photosynthesis of plants increases with the amount of light, but the ginseng has a lower light saturation point at high temperatures, and the higher the amount of light, the lower the photosynthetic efficiency. The SPAD (chlorophyll content) value decreased as the increase of light-receiving rate, and was the highest at 32.7 in 9% light blue-white plastic house. Ginseng germination started on April 11 and took 13-15 days to germinate. The overall germination rate was 82.9-85.8%. The plant height and length of stem were long in the 9% light-receiving plastic house. The diameter of stem was thick in the 12-14% light-receiving plastic house. In the 12% and 14% light-receiving plastic house, the length and diameter of taproot was long and thick, so the fresh weight of root per plant was 20 g or more, which was heavier than 16.9 g of the 9% light-receiving plastic house. The disease incidence (Alternaria blight, Gray mold and Damping-off etc.) rate were 0.9-2.7%. The incidence of Sclerotinia rot disease was 7.5-8.4%, and root rot was 0-20.0%. The incidence ratio of rusty root ginseng was 34.4-38.7% level, which was an increase from the previous year's 15% level.

  • PDF

The actual type of domestic safety accident of children and the safety knowledge according to variables of parents (가정내 유아의 안전사고 유형과 부모의 변인에 따른 안전지식)

  • Kim, Ji-Young;Kim, Na-Rim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.454-461
    • /
    • 2017
  • The purpose of this study is to investigate the types of domestic safety accidents involving children and to verify the difference of safety knowledge according to variables of parents. Subjects include 226 parents who have 3-5 year old infants enrolled in kindergartens and day care centers in I-city, Jeollabuk-do. The study tools are modified and complemented questionnaire for the study purpose referred to the preceding research data and the literature. For the processing of collected data, frequency analysis, descriptive statistics, one-way ANOVA, and the Duncan post-test were utilized using the SPSS program. The results of this study are as follows: First, safety accidents occurred at the majority of homes which have infant children. On average, the occurrence frequency was 1.78 times per six months. The accidents involving infants occurred in the order of drop or slip, crash or impact, stricture or jamming, fall, stab or cut, burn, swallow or inhalation. Second, both parents had an average level of safety knowledge. There was a distinction in the areas of 'fall' and 'first aid' according the mother's age. In addition, stay-at-home mothers had the higher level of safety knowledge compared with working mothers in the areas of 'general safety knowledge' and 'fire'. There was a distinction in the area of 'fire' according to the father's age. Given these findings, safety training programs for parents to improve safety knowledge needs to be developed.

A Study on Rehabilitation Treatment Using Radiofrequency Treatment (고주파 통증치료기를 이용한 재활 치료에 대한 연구)

  • Jo, Jae-Hyun;Lee, Sang-Yong;Lee, Geun-Yong;Yoon, Se-Jin;Cheong, Ha-Young;Lee, Sang-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.3
    • /
    • pp.212-218
    • /
    • 2020
  • When Radiofrequency energy is applied to the human body, the vibration width is very short. Therefore, the electrolyte burn generated when using the direct current does not occur. Ion molecules, polarized molecules, etc., vibrate more than 40,000 times per second, converting them into frictional heat to generate deep heat. The blood flow of capillaries increases 4-5 times more than at rest, increasing the supply of oxygen, nutrients, antibodies, and white blood cells. In addition, the electrochemical reaction does not occur because the vibration width and the pulsation period are very short. It is a physical factor treatment method that does not stimulate the sensory nerves and motor nerves. In this study, an isotonic exercise is performed in a young normal adult using a Radiofrequency pain treatment device. The purpose of this study is to integrate rehabilitation therapy by measuring electromyography data during isotonic exercise and confirming the effect on changes in motor neuron response. The EMG data generated when isotonic exercise of the forearm biceps muscle and the EMG data measured after the use of a Radiofrequency pain treatment device after exercise were RMS, respectively, and verified through t-test. It was confirmed that there was a significant difference in both men and women because the t-value was smaller than the significance level p (<.05).

Effect of Physiochemical Properties of Seokganju on Functionality and Light Fastness (석간주의 이화학적 특성이 기능성 및 내광성에 미치는 영향 연구)

  • Park, Ju Hyun;Jeong, Hye Yeong;Mun, Seong Woo;Woo, In Suk
    • Journal of Conservation Science
    • /
    • v.33 no.6
    • /
    • pp.485-495
    • /
    • 2017
  • The purpose of this study is to evaluate the functionality and lightfastness of the natural pigments according to the type of Seokganju used as Dancheong. The commercially available red iron-oxide-based natural pigments that are called Seokganju and Daija manufactured by traditional methods in Korea and Japan were selected. The analysis of the constituent minerals and constituents of 8 kinds of collected Seokganju showed that most of them contained hematite. There are two types of Seokganju according to the $Fe_2O_3$ contents. The type of Seokganju can be characterized not only using the main component but also from the burn-out processing. The chromaticity results for Seokganju with a high $Fe_2O_3$ concentration indicate dark red or grayish brown, while those for Seokganju with a low $Fe_2O_3$ concentration indicate yellowish red or yellowish brown. Samples were prepared by mixing with a glue solution and functional properties were evaluated based on the opacity and spreadability. Coated samples were used in the lightfastness test. The spreadability and opacity of the pigments were measured differently depending on the main component. Most Seokganju samples a showed slight color change until $9,000kJ/m^2$ but rapid color changes were detected after $18,000kJ/m^2$. In particular, burnt Seokganju showed superior lightfastness.

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Scintigraphic Evaluation of Inhalation Injury in Fire Victims (화재사고시 흡입에 의한 기도손상의 핵의학적 평가)

  • Chun, Kyung-Ah;Cho, Ihn-Ho;Won, Gyu-Jang;Lee, Hyung-Woo;Shin, Kyung-Chul;Jeong, Jin-Hong;Lee, Gwan-Ho
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.28-32
    • /
    • 2006
  • Purpose: Conventional chest X-ray and pulmonary function test cannot sensitively detect inhalation injury. Bronchoscopy is known to be the gold standard but it is invasive method. We evaluated whether lung inhalation/perfusion scans can sensitively detect inhalation injury of fire victims. Materials and Methods: Nineteen patients (male 9, female 10, mean age 31.6 yr) of fire victims were enrolled in this study. Inhalation lung scan was performed 2 days later after inhalation injury with $^{99m}Tc$-technegas. Perfusion lung scan was performed 4 days later with $^{99m}Tc$- MAA (macroaggregated albumin). Follow up lung scans were performed 16 and 18 days later for each. Chest X-ray was performed in all patients and bronchoscopy was performed in 17 of 19 patients at the same period. Pulmonary function test was performed in 9 patients. Results: Four of 19 patients showed inhalation and perfusion defects and one showed inhalation defect but, normal perfusion scan findings. These five patients with abnormal scan findings showed abnormal bronchoscopic findings and severe respiratory symptoms. On chest X-ray, 2 of them had pulmonary tuberculosis and one of them showed pulmonary congestion. FEV1 /FVC was abnormal in 3 patients. On the follow up scan, all patients with abnormal initial scan findings showed improved findings and they had improved clinical state. Conclusion: Inhalation/perfusion lung scans can detect inhalation burn injury noninvasively in early stage and may be useful in therapeutic decision making and follow up of patients.