• Title/Summary/Keyword: Buffer Function

Search Result 345, Processing Time 0.024 seconds

Performance Analysis of Request Handling Schemes for Intelligent Peripherals (IP용 서비스 요청 처리방식의 성능 분석)

  • 최고봉;윤종호;권기호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.7
    • /
    • pp.1321-1334
    • /
    • 1994
  • This paper presents the service handling schemes of an intelligent peripheral(IP) which provides the service function as a physical entity in the intelligent network. Four service request handling scheme are compared for and IP which can handle both ordinary requests and prioritized requests on the blocked-call-delayed basis. Delayed requests are assumed to be stored in a finite storage buffer. Scheme-I exclusively allows prioritized requests be stored and to use a fixed number of reserved servers. The other three schemes without reserved servers(Scheme-II.III,and IV) allow both types of requests to be stored and prioritized requests pushout ordinary requests if the buffer is full. For these four schemes, the blocking probabilities and delay distributions of both types of requests are numerically obtained. From the numericall results, the schemes without reserved servers reduce the blocking probability of ordinary requists without a severe penalty on proritized requests. For three schemes without reserved servers, it is noted that prioritized requests should br served on the first-in, first-out basis, and ordinary requests should be served on the last-in, first-out basis.

  • PDF

Effect of Reperfusate Solution with Latamoxef Sodium for Functional Recovery after Ischemic Cardiac Arrest in Sprague-dawley`s Isolated Heart (재관류액에 Latamoxef Sodium 첨가가 허혈성 심정지후 흰쥐 적출심장의 기능회복에 미치는 영향)

  • Ahn, B.H.;Hur, S.
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.331-337
    • /
    • 1991
  • Recent experimental work indicates latamoxef sodium used as a broadspectrum antibiotics generates oxygen-free radicals. The present study represents an attempt to investigate whether reperfusate containing Shiomarin[85% latamoxef sodium+15% mannitol] might decrease the post-ischemic recovery of cardiac function. In the investigation, twelve isolated rat hearts were subjected to 270 minutes of cold total global ischemia. After the cold total global ischemia, six hearts[KHB group] were reperfused with Krebs-Henseleit buffer solution and the other six hearts[LMS group] with Krebs-Henseleit buffer solution containing latamoxef sodium[200ug /L]. Postischemic recovery rate of heart rate, aortic systolic pressure, aortic flow, coronary flow and cardiac output at 20 minutes reperfusion was 100.66$\pm$10.38, 85.25$\pm$7.61, 78.95$\pm$6. 02, 78.85$\pm$8.86 and 79.11$\pm$6.54 percent respectively in the KHB group and 97.96$\pm$4.19, 87. 72$\pm$4.37, 81.74$\pm$6.80, 82.69$\pm$10.01 and 81.90$\pm$6.67 percent respectively in the LMS group. The hemodynamic data revealed no significant difference in the post-ischemic recovery rate of the two groups. This finding suggests that reperfusate containing Shiomarin[latamoxef sodium, 200ug /L] does not affect the cardiac functional recovery after cold total global ischemia.

  • PDF

The Design of Multi-channel Synchronous and Asynchronous Communication IC for the Smart Grid (스마트그리드를 위한 다채널 동기 및 비동기 통신용 IC 설계)

  • Ock, Seung-Kyu;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.4
    • /
    • pp.7-13
    • /
    • 2011
  • In this paper, the IC(Integrated Circuit) for multi-channel synchronous communication was designed by using FPGA and VHDL language. The existing chips for synchronous communication that has been used commercially are composed for one to two channels. Therefore, when communication system with three channels or more is made, the cost becomes high and it becomes complicated for communication system to be realized and also has very little buffer, load that is placed into Microprocessor increases heavily in case of high speed communication or transmission of high-capacity data. The designed IC was improved the function and performance of communication system and reduced costs by designing 8 synchronous communication channels with only one IC, and it has the size of transmitter/receiver buffer with 1024 bytes respectively and consequently high speed communication became possible. It was designed with a communication signal of a form various encoding. To detect errors of communications, the CRC-ITU-T logic and channel MUX logic was designed with hardware logics so that the malfunction can be prevented and errors can be detected more easily and input/output port regarding each communication channel can be used flexibly and consequently the reliability of system was improved. In order to show the performance of designed IC, the test was conducted successfully in Quartus simulation and experiment and the excellence was compared with the 85C3016VSC of ZILOG company that are used widely as chips for synchronous communication.

The Design of Multi-channel Synchronous Communication IC Using FPGA (FPGA를 이용한 다채널 동기 통신용 IC 설계)

  • Yang, Oh;Ock, Seung-Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2011
  • In this paper, the IC(Integrated Circuit) for multi-channel synchronous communication was designed by using FPGA and VHDL language. The existing chips for synchronous communication that has been used commercially are composed for one to two channels. Therefore, when communication system with three channels or more is made, the cost becomes high and it becomes complicated for communication system to be realized and also has very little buffer, load that is placed into Microprocessor increases heavily in case of high speed communication or transmission of high-capacity data. The designed IC was improved the function and performance of communication system and reduced costs by designing 8 synchronous communication channels with only one IC, and it has the size of transmitter/receiver buffer with 1024 bytes respectively and consequently high speed communication became possible. It was designed with a communication signal of a form various encoding. To detect errors of communications, the CRC-ITU-T logic and channel MUX logic was designed with hardware logics so that the malfunction can be prevented and errors can be detected more easily and input/output port regarding each communication channel can be used flexibly and consequently the reliability of system was improved. In order to show the performance of designed IC, the test was conducted successfully in Quartus simulation and experiment and the excellence was compared with the 85C3016VSC of ZILOG company that are used widely as chips for synchronous communication.

A Change of Awareness on the Ondol System and Architectural Seeking for Increasing Heating Efficiency since the 18th Century Joseon Society (18세기 이후 조선사회의 온돌에 대한 인식변화와 난방효율 증대를 위한 건축적 모색)

  • Chung, Jung-Nam
    • Journal of architectural history
    • /
    • v.27 no.3
    • /
    • pp.15-26
    • /
    • 2018
  • As a result of reviewing various documents and existing researches, since the late Goryeo period, the most active period in the Ondol(溫突, Korean floor heating system) facilities is the 17th century. The phenomenological reason was recovering the buildings destroyed by the Japanese Invasion of Korea in 1592(壬辰倭亂) & the Manchu War of 1636(丙子胡亂), but the underlying cause was an abnormal climate in which a pair of summer and winter cold continued. In the 17th century, as the Ondol facilities grew rapidly without distinction between regions and classes, the supply and demand of fuel caused economic and natural environmental problems. And a negative and positive view on Ondol was suggested. Since the middle of the 18th century, when the demand and supply of Ondol reached its peak, which could no longer increase, a new awareness of Ondol began to grow. The room was called the Panbang(板房) and the Ondol, depending on the material that made up the floor. It was considered natural to have the Ondol from this time on. The Incan(因間) and Jo(竈) that were made to burn were started to be recorded as a kitchen, regardless of size and function. Changes in social awareness of Ondol have led to concerns about heating efficiency. A variety of architectural explorations were conducted. Such a search was later realized in concrete architectural form. There is a double Ondoll structure, and the column spacing is reduced compared to the previous one. The heat buffer space is formed around the Ondol room, and the double window can control the light and the air going in and out.

Cell-interleavd VC merging scheme for multipoint-to-multipoint communication in ATM network (ATM 망에서의 다자간 통신을 위한 cell-interleaved VC merging 기법)

  • 신상헌
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.9A
    • /
    • pp.1431-1440
    • /
    • 2000
  • In order to support efficiently the multimedia applications, such as virtual classroom, video conferencing and tele-medical, the efficient multipoint-to-multipoint(MP-to-MP) connection management function is essential. Shared tree is reported as the most useful method for this purpose. In this paper we propose a new MP-to-MP connection setup & management scheme, called CIMA(Cell Interleaved Multiplexing on ATM) scheme,which is a VC merging method for MP-to-MP communication using shared tree. In the CIMA scheme,MRM cell delivers the cell merging information to the next node. The receiving node can identfy cells which arrived through a channel using the same VPI/VCI by the merging information in the MRM cell. Therefore the CIMA scheme can solve easily the Cell Interleaving Problem(CIP) that happens in VC merging. We analyzed the overhead of the proposed CIMA by mathematical analysis,and simulated the buffer usage of CIMA with OPNET. As the result of analysis,we found that the CIMA scheme has acceptable merging overhead and doesn't cause the buffer scare problem.

  • PDF

EFFECT OF PH AND STORAGE TIME ON THE ELUTION OF RESIDUAL MONOMERS FROM POLYMERIZED COMPOSITE RESINS (산도변화와 침지시간이 광중합 복합레진의 잔류단량체 유출에 미치는 영향)

  • Jeon, Cheol-Min;Yoo, Hyun-Mi;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.249-266
    • /
    • 2004
  • The purpose of this study was to determine whether pH and time has any influence on the degradation behavior of composite restoration by analyzing the leached monomers of dental composites qualitatively and quantitatively after storage in acetate buffer solution as a function of time using high performance liquid chromatography (HPLC) / mass spectrometer. Materials and Methods:Three commercial composite restorative resin materials (Z-250, Heliomolar and Aeliteflo) with different matrix structure and filler composition were studied. Thirty specimens (7mm $diameter{\times}2mm$ thick) of each material were prepared. The cured materials were stored in acetate buffer solution at different pH (4, 7) for 1, 7 and 45days. As a reference, samples of unpolymerized composite materials of each product were treated with methanol (10mg/ml). Identification of the various compounds was achieved by comparison of their mass spectra with those of reference compound, with literature data. and by their fragmentation patterns. Data were analysed statistically using ANOVA and Duncan's test. Results:1. Amounts of leached TEGDMA in Aeliteflo were significantly larger than those of UDMA in Z-250 and Heliomolar at experimental conditions of different storage time and pH variation (p<0.001). 2. As to comparison of the amounts of leached monomers per sorage time, amounts of leached TEGDMA in Aeliteflo and UDMA in Z-250 and Heliomolar were increased in the pH 4 solution more significantly than in the pH 7 solution after 1day, 7days and 45days, respectively (p<0.001). 3. In total amounts of all the leached monomers with storage times, the overall amounts of pH 4 extracts were larger than those of pH 7 extracts for all resin groups, but there was no significant difference (p>0.05).

Limitations and Future Work Suggetion on Safe Interaction Model between Rust and C/C++ (Rust와 C/C++간 안전한 상호작용에 관한 연구의 맹점과 개선 모델 연구)

  • Taehyun Noh;Hojoon Lee
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.345-351
    • /
    • 2023
  • As software development progresses and programs become increasingly complex, the cost of reducing and managing software vulnerabilities has also increased. To address this issue, the Rust programming language, which guarantees Memory Safety, has been suggested as an alternative for more error-prone languages such as traditional C/C++. However, Rust also supports the use of libraries written in C/C++ to enhance compatibility with older languages and avoid redundant development, compromising its original guarantees. For example, memory corruption happened in C/C++ can lead to exploits such as buffer overflow, Use-After-Free and null-pointer dereferecing. To tackle this problem, recent studies have been conducted to secure interactino between Rust and C/C++ by isolation. This paper uncovers areas that have not been fully explored in previous studies, following limitation analysis on each. Finally, this paper suggests the future direction of research on safe interaction between Rust and C/C++.

An Experimental Study on the Sorption of Uranium(VI) onto a Bentonite Colloid (벤토나이트 콜로이드로의 우라늄(VI) 수착에 대한 실험적 연구)

  • Baik Min-Hoon;Cho Won-Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.3
    • /
    • pp.235-243
    • /
    • 2006
  • In this study, an experimental study on the sorption properties of uranium(VI) onto a bentonite colloid generated from Gyeongju bentonite which is a potential buffer material in a high-level radioactive waste repository was performed as a function of the pH and the ionic strength. The bentonite colloid prepared by separating a colloidal fraction was mainly composed of montmorillonite. The concentration and the size fraction of the prepared bentonite colloid measured using a gravitational filtration method was about 5100 ppm and 200-450 nm in diameter, respectively. The amount of uranium removed by the sorption reaction bottle walls, by precipitation, and by ultrafiltration was analyzed by carrying out some blank tests. The removed amount of uranium was found not to be significant except the case of ultrafiltration at 0.001 M $NaClO_4$. The ultrafiltration was significant in the lower ionic strength of 0.001 M $NaClO_4$ due to the cationic sorption onto the ultrafilter by a surface charge reversion. The distribution coefficient $K_d$ (or pseudo-colloid formation constant) of uranium(VI) for the bentonite colloid was about $10^4{\sim}10^7mL/g$ depending upon pH and ionic strength of $NaClO_4$ and the $K_d$ was highest in the neutral pH around 6.5. It is noted that the sorption of uranium(VI) onto the bentonite colloid is closely related with aqueous species of uranium depending upon geochemical parameters such as pH, ionic strength, and carbonate concentration. As a consequence, the bentonite colloids generated from a bentonite buffer can mobilize the uranium(VI) as a colloidal form through geological media due to their high sorption capacity.

  • PDF

The Design of Multi-channel Asynchronous Communication IC Using FPGA (FPGA를 이용한 다채널 비동기 통신용 IC 설계)

  • Ock, Seung-Kyu;Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.28-37
    • /
    • 2010
  • In this paper, the IC (Integrated Circuit) for multi-channel asynchronous communication was designed by using FPGA and VHDL language. The existing chips for asynchronous communication that has been used commercially are composed of one to two channels. Therefore, when communication system with two channels or more is made, the cost becomes high and it becomes complicated for communication system to be realized and also has very little buffer, load that is placed into Microprocessor increases heavily in case of high speed communication or transmission of high-capacity data. The designed IC was improved the function and performance of communication system and reduced costs by designing 8 asynchronous communication channels with only one IC, and it has the size of transmitter/receiver buffer with 256 bytes respectively and consequently high speed communication became possible. To detect errors between communications, it was designed with digital filter and check-sum logic and channel MUX logic so that the malfunction can be prevented and errors can be detected more easily and input/output port regarding each communication channel can be used flexibly and consequently the reliability of system was improved. It was composed and simulated logic of VHDL described by using Cyclone II Series EP2C35F672C8 and QuartusII V8.1 of ALTERA company. In order to show the performance of designed IC, the test was conducted successfully in QuartusII simulation and experiment and the excellency was compared with TL16C550A of TI (Texas Instrument) company and ATmegal28 general-purpose micro controller of ATMEL company that are used widely as chips for asynchronous communication.