• Title/Summary/Keyword: Broad-band time signal

Search Result 14, Processing Time 0.027 seconds

Measurement of Blood Oxygen Saturation System and LavVIEW Program Using Broad-band Light Source (광대역 광원을 이용한 혈중 산소포화도의 측정 시스템 및 랩뷰 프로그램)

  • Cui, Jin Shi;Shin, Dong Ho;Song, Chul Gyu
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.2
    • /
    • pp.128-137
    • /
    • 2015
  • Blood oxygen saturation ($SpO_2$) is so important to be called bio-signal of the fifth. The measurement of blood oxygen saturation based on broad-ban light source has advantages of simple testing facility and easy understanding. This paper proposes a LabVIEW program which measures blood oxygen saturation based on broad-band light source. It combines LabVIEW and MATLAB, utilizing different light absorptions of oxyhemoglobin and deoxyhemoglobin in the visual wavelength range of 450nm-750nm to determine blood oxygen saturation. In order to improve accuracy through reducing the impact of hand shaking, the probe is fixed to the motor stage and then move a constant distance between the probe and the sample to be measured. Experimental results show that the proposed method noticeably increases the accuracy and saves time compared with the conventional methods.

Optical IIR lattice fiber filter design for optimum of optical signal energy (광신호 에너지 최적화를 위한 IIR 격자형 광파이버필터 설계)

  • 이채욱;김신환
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.11
    • /
    • pp.1481-1488
    • /
    • 1995
  • Due to the low loss, broadband and accurate short time delay properties of optical fiber, it has attracted as a delay medium for high speed and broad-band signal processing. In this paper, we consider the coherent optical fiber filter of IIR lattice structure, which uses coherent light sources and consists of directional couplers whose coupling coefficients are restricted between 0 and 1. Considering restrictions of directional coupler, the design formulae and condition for realibility of optical fiber filter of IIR lattice structure which makes the optimal use of optical signal energy are derived.

  • PDF

A Fast Algorithm for Real-time Adaptive Notch Filtering

  • Kim, Haeng-Gihl
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.4
    • /
    • pp.189-193
    • /
    • 2003
  • A new algorithm is presented for adaptive notch filtering of narrow band or sine signals for embedded among broad band noise. The notch filter is implemented as a constrained infinite impulse response filter with a minimal number of parameters, Based on the recursive prediction error (RPE) method, the algorithm has the advantages of the fast convergence, accurate results and initial estimate of filter coefficient and its covariance is revealed. A convergence criterion is also developed. By using the information of the noise-to-signal power, the algorithm can self-adjust its initial filter coefficient estimate and its covariance to ensure convergence.

A Study on the Ray Based Broad Band Modeling for Shallow Water Acoustic Wave Propagations (천해 음파전달 모의에 적합한 음선기반 광대역 신호 모델링 기법에 관한 연구)

  • Park Cheol-Soo;Cho Yong-Jin;Ahn Jong-Woo;Seong Woo-Jae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.6
    • /
    • pp.298-304
    • /
    • 2006
  • This paper proposes a ray-based forward modeling scheme which is suitable for the shallow water acoustic wave propagation simulations. The proposed model comprises of ray tracings for the layered media of which sound speed profiles are interpolated linearly. considerations of plane and spherical wave reflection coefficients. and calculations of the phases and the amplitudes of eigen rays. The main characteristic of the scheme is fast simulation time due to direct calculation of the broad-band time signals in the time-domain, i.e. without transformation of the frequency-domain solutions to the time si 밍 131s. Finally, we applied the model to 4-types of test environments and compared the resulting signals with those of ORCA and Ram in order to validate the proposed model.

The Design of 50MHz-3GHz Wide-band Amplifier IC Using SiGe HBT (SiGe HBT를 이용한 50MHz-3GHz 대역폭의 광대역 증폭기 IC 설계)

  • 이호성;박수균;김병성
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.257-261
    • /
    • 2001
  • This paper presents the implementation of wide-band RFIC amplifier operating from near 50MHz to 3GHz using Tachyonics SiGe HBT foundry. Voltage shunt feedback is used for the flat gain and the broad band impedance matching. Initial design parameters are calculated using the low frequency small signal analysis. Since the HBT model was not available at the design time, discrete tuning board was made for fine tuning in the low frequency range. Fabricated amplifier shows 12dB gain with 1dB fluctuation and PldB reaches 15dBm at 850MHz.

  • PDF

An Optimal Design Method for Optical Fiber Filter of Lattice Structure (격자형 광파이버필터의 최적설계에 관한 연구)

  • 이채욱;문병현;우홍채
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.5
    • /
    • pp.34-42
    • /
    • 1993
  • Due to the low loss, broadband and accurate short time delay properties of optical fiber, it has attracted as a delay medium for high speed and broad-band signal processing. In this paper, we consider the coherent optical fiber filter of lattice structure, which uses coherent light sources and consists of directional couplers and optical fiber delay elements.The differences between the optical fiber filter and the ordinary digital filter are 1) the coupling coefficients of directional couplers are restricted between 0 and 1. 2) the optical signal is divided into ${j\sqrt{a}}and\;{j\sqrt{1-a}}$ at the directional coupler. Considering these restrictions, the design formulae and condition of realibility for optical fiber filter of lattice structure which makes the optimal use of optical signal energy are derived.

  • PDF

Pattern Recognition for the Target Signal Using Acoustic Scattering Feature Parameter (표적신호 음향산란 특징파라미터를 이용한 패턴인식에 관한 연구)

  • 주재훈;신기철;김재수
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.93-100
    • /
    • 2000
  • Target signal feature parameters are very important to classify target by active sonar. Two highly correlated broad band pulses separated by time T have a time separation pitch(TSP) of 1/T Hz which is equal to the trough-to-trough or peak-to-peak spacing of its spectrum. In this study, TSP informations which represent feature of each target signal were effectively extracted by the FFT. The extracted TSP feature parameters were also applied to the pattern recognition algorithm to classify target and to analyze their properties.

  • PDF

Echolocation Signals of Pipistrellus abramus in Relation to Environmental Type (환경특성에 따른 집박쥐의 반향정위(Echolocation) 시그널 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Kim, Sung-Chul;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.23 no.6
    • /
    • pp.553-563
    • /
    • 2009
  • This study was conducted to analyze the changes in the echolocation of Pipistrellus abramus according to environmental characteristics. The survey was conducted in the day-roosting site of P. abramus located in Gyeongju City (North Gyeongsang Province) from April to August, 2009. The environmental characteristics during the research were classified in six categories: the emergence time after sunset moving time from day roost to feeding areas; rice fields; forest edges; open spaces; and residential areas. Analysis results showed that there are differences in environmental characteristics and also differences between the moving time to the habitat and the moving time to capture preys. At the emergence time from day roost, Pipistrellus abramus used a FM signal with a short pulse-duration. In open spaces, however, they used a CF signal with a long pulse-duration. In different environmental situations, they used both FM and CF signals, although the types of pulse which they used were different. Except pulse-duration, there were significant differences in pulse-interval, peak-frequency, starting-frequency and ending-frequency between the movement among habitats and the movement to capture preys. Except the emergence time from day-roost, they showed a narrow band FM signal and a long pulse-duration that are suitable to search for insects by sensing echoes of insects when they moved among their habitats. When they were out to capture their preys, they showed a broad band FM signal and a short pulse-duration which enabled them to widely search and accurately locate their preys.

The Design of 50 MHz~3 GHz Wide-band Amplifier IC using SiGe HBT (SiGe HBT를 이용한 50 MHz~3 GHz 대역폭의 광대역 증폭기 IC 설계)

  • 이호성;김병성;박수균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.68-73
    • /
    • 2002
  • This paper presents the implementation of wide-band RFIC amplifier operating from near 50 MHz to 3 GHz using Tachyonics SiGe HBT foundry. Voltage shunt feedback is used for the flat gain and the broad band impedance matching. Initial design parameters are calculated through the low frequency small signal analysis. Since the HBT model was not available at the design time, discrete tuning board was made for fine adjustment in the low frequency range. Fabricated amplifier shows 12 dB gain with 1 dB fluctuation and P1 dB reaches 15 dBm at 850 MHz.

A Study on Vital Signal Detection Using UWB Pulse (UWB 펄스를 이용한 인체 신호 검출 방법 연구)

  • Jang, Dong-Won;Choi, Jae-Ik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.465-468
    • /
    • 2014
  • In this paper, we describe a method capable of measuring biological signals including respiration, heart rate, blood pressure, and blood sugar, using UWB (Ultra Wide Band) pulses, while does not contact the human body. Physiological signal is a basic data for checking the health. Because life is longer and active area of human becomes very broad, the medical system and the physical human resources which are focused on existing hospital must be located close patient, In that way, they hope be to engage in healthy life by stepping a quick step and treatment. Thus, it must be fitted closely to the patient. It is necessary to monitor the health without inconvenience on an ongoing basis. How to utilize radio waves in this way have been studied for a long time. However, the characteristics of radio waves on the human body has not been accurately grasped and developed as such. Accordingly, it is a level that can not be applied clinically. So, it is not widely put to practical use. In this paper, We analyzed and described the impact and characteristics of UWB pulses to the human body is a problem existing.

  • PDF