1 |
H. Radhakrishnan, Use of Near Infrared And Visible Spectroscopies to Determine Optical Properties of Rat Nervous System, Master's Thesis of Texas University, 2006.
|
2 |
S.J. Matcher, M. Cope, and D.T. Delpy, "In Vivo Measurements of The Wavelength Dependence of Tissue Scattering Coefficients Between 760 And 900 nm Measured With Time-resolved Spectroscopy," Appled Optics, Vol. 36, No. 1, pp. 386-396, 1997.
DOI
|
3 |
W.G. Zijlstra, A. Buursma, and W.P.M. Roest, "Absorption Spectra of Human Fetal And Adult Oxy-hemoglobin, Deoxy-hemoglobin, Carboxyhemoglobin And Methemoglobin," Clinical Chemistry, Vol. 37, No. 9, pp. 1633-1638, 1991
|
4 |
R. Maddipatla, K. Bose, and R. Poddar, "Noninvasive Measurement of Relative Blood Oxygen Saturation in Human Retina by using 1 μm Fourier Domain Optical Coherence Tomography", International Journal of Innovative Research in Science, Engineering and Technology, Vol. 2, No. 12, pp. 7168-7172, 2013.
|
5 |
K. Vishwanath, K. Chang, D. Klein, Y.F. Deng, V. Chang, J.E. Phelps, et al., " Portable, Fiber-Based, Diffuse Reflection Spectroscopy (DRS) System for Estimation Tissue Optical Properties," Applied Spectroscopy, Vol. 62, No. 2, pp. 206-215, 2011.
DOI
|
6 |
Y. Liu, S.H. Lee, S.G. Kwon and K.R. Kwon, "Skin Pigmentation Detection Using Projection Transformed Block Coefficient," Jornal of Korea Multimedia Society, Vol. 16, No. 9, pp. 1044- 1056, 2013.
DOI
|
7 |
T. Ukawa, K. Ito, and T. Nakayama, Pulse Oximeter, 5355882, U.S., 1994.
|
8 |
J.R. Mourant, T. Fuselier, J. Boyer, T.M. Johnson, and I.J. Bigio, "Predictions and Measurement of Scattering and Absorption Over Broad Wavelength Ranges in Tissue," Appled Optics, Vol. 36, No. 4, pp. 949-957, 1997.
DOI
|
9 |
M. Johns, C.A. Giller, D.C. German, and H. Liu., "Determination of Reduced Scattering Coefficient of Biological Tissue from A Needle-like Probe," Optics Express, Vol. 13, No. 13, pp. 4828-4842, 2005.
DOI
|
10 |
G.H. Kim, D.G. Seo, S.N. Yang, U.Y. Han, RN, et al., "Reduce Inspection Time by Improving Oxygen Saturation Measurement of Sedation Patient during MR Examination," Proceeding of the National Radiological Conference, pp. 128, 2011.
|
11 |
B. Khoobehi, A. Eaton, H. Wafapoor, P. fournier, F. Kim, P. Matt, et al., "Determination of Oxygen Saturation of the Optic Nerve Head and Overlying Artery and Vein using A Snapshot Multi-spectral Imaging System," Processing of International Conference Society of Photo-Optical Instrumentation Engineers, Vol. 8229, No. 01, pp. 1-19, 2012.
|
12 |
J. Laufer, C. Elwell, D. Delpy, and P. Beard, "In Vitro Measurements of Absolute Blood Oxygen Saturation using Pulsed Near-infrared Photoacoustic Spectroscopy: Accuracy and Resolution," Physics in Medicine and Biology, Vol. 50, No. 18, pp. 4409-4428, 2005.
DOI
|
13 |
B. Venema, N. Blanik, V. Blazek, H. Gehring, A. Opp, and S. Leonhardt, "Advances in Reflective Oxygen Saturation Monitoring with A Novel In-ear Sensor System: Results of A Human Hypoxia Study," IEEE Transactions Biomedical Engineering, Vol. 59, No. 7, pp. 2003-2010, 2012.
DOI
|