• 제목/요약/키워드: Barrier factor

검색결과 446건 처리시간 0.03초

의류제품 구매시 소비자의 전환장벽지각이 점포충성도에 미치는 영향 (The Effect of Consumer’s Switching Barrier Perception on Store Loyalty in Apparel Product Purchasing)

  • 김수진;정명선
    • 한국의류학회지
    • /
    • 제25권8호
    • /
    • pp.1512-1523
    • /
    • 2001
  • The purposes of this study were to examine the effect of switching barrier perception on store loyalty in apparel product purchasing to classify the factors of switching barrier perception, and additionally ot identify differences of store loyalty and switching barrier perception according to demographic characteristics. The questionnaire was administered to 300 women shopped in a department store in Gwang-ju city during February 10-23, 2001. Data collected from 261 women were analyzed by using frequency, factor analysis, ANOVA, Duncan-test, regression analysis by SPSS for windows PC program. The results were as follows; 1. The consumer’s perceived switching barrier was composed of three factors; economic psychological, time factor. 2. There was significant difference in store loyalty according to consumer’s age, occupation, education level. and income. 3. There was significant differences in economic. time switching barrier perception according to consumers’age, occupation education level, and income. There was significant difference in psychological switching barrier perception according to consumers’ occupation education level, and income. 4. The swiching barrier perception significantly infulenced on the store loyalty.

  • PDF

Analysis of Electrical Properties of Ti/Pt/Au Schottky Contacts on (n)GaAs Formed by Electron Beam Deposition and RF Sputtering

  • Sehgal, B-K;Balakrishnan, V-R;R Gulati;Tewari, S-P
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제3권1호
    • /
    • pp.1-12
    • /
    • 2003
  • This paper describes a study on the abnormal behavior of the electrical characteristics of the (n)GaAs/Ti/Pt/Au Schottky contacts prepared by the two techniques of electron beam deposition and rf sputtering and after an annealing treatment. The samples were characterized by I-V and C-V measurements carried out over the temperature range of 150 - 350 K both in the as prepared state and after a 300 C, 30 min. anneal step. The variation of ideality factor with forward bias, the variation of ideality factor and barrier height with temperature and the difference between the capacitance barrier and current barrier show the presence of a thin interfacial oxide layer along with barrier height inhomogenieties at the metal/semiconductor interface. This barrier height inhomogeneity model also explains the lower barrier height for the sputtered samples to be due to the presence of low barrier height patches produced because of high plasma energy. After the annealing step the contacts prepared by electron beam have the highest typical current barrier height of 0.85 eV and capacitance barrier height of 0.86 eV whereas those prepared by sputtering (at the highest power studied) have the lowest typical current barrier height of 0.67 eV and capacitance barrier height of 0.78 eV.

Estrogen reinforces barrier formation and protects against tumor necrosis factor alpha-induced barrier dysfunction in oral epithelial cells

  • Choi, Yun Sik;Baek, Keumjin;Choi, Youngnim
    • Journal of Periodontal and Implant Science
    • /
    • 제48권5호
    • /
    • pp.284-294
    • /
    • 2018
  • Purpose: Epithelial barrier dysfunction is involved in the pathophysiology of periodontitis and oral lichen planus. Estrogens have been shown to enhance the physical barrier function of intestinal and esophageal epithelia, and we aimed to investigate the effect of estradiol (E2) on the regulation of physical barrier and tight junction (TJ) proteins in human oral epithelial cell monolayers. Methods: HOK-16B cell monolayers cultured on transwells were treated with E2, an estrogen receptor (ER) antagonist (ICI 182,780), tumor necrosis factor alpha ($TNF{\alpha}$), or dexamethasone (Dexa), and the transepithelial electrical resistance (TER) was then measured. Cell proliferation was measured by the cell counting kit (CCK)-8 assay. The levels of TJ proteins and nuclear translocation of nuclear factor $(NF)-{\kappa}B$ were examined by confocal microscopy. Results: E2 treatment increased the TER and the levels of junctional adhesion molecule (JAM)-A and zonula occludens (ZO)-1 in a dose-dependent manner, without affecting cell proliferation during barrier formation. Treatment of the tight-junctioned cell monolayers with $TNF{\alpha}$ induced decreases in the TER and the levels of ZO-1 and nuclear translocation of $NF-{\kappa}B$. These $TNF{\alpha}-induced$ changes were inhibited by E2, and this effect was completely reversed by co-treatment with ICI 182,780. Furthermore, E2 and Dexa presented an additive effect on the epithelial barrier function. Conclusions: E2 reinforces the physical barrier of oral epithelial cells through the nuclear ER-dependent upregulation of TJ proteins. The protective effect of E2 on the $TNF{\alpha}-induced$ impairment of the epithelial barrier and its additive effect with Dexa suggest its potential use to treat oral inflammatory diseases involving epithelial barrier dysfunction.

Forward Current Transport Mechanism of Cu Schottky Barrier Formed on n-type Ge Wafer

  • Kim, Se Hyun;Jung, Chan Yeong;Kim, Hogyoung;Cho, Yunae;Kim, Dong-Wook
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.151-155
    • /
    • 2015
  • We fabricated the Cu Schottky contact on an n-type Ge wafer and investigated the forward bias current-voltage (I-V) characteristics in the temperature range of 100~300 K. The zero bias barrier height and ideality factor were determined based on the thermionic emission (TE) model. The barrier height increased and the ideality factor decreased with increasing temperature. Such temperature dependence of the barrier height and the ideality factor was associated with spatially inhomogeneous Schottky barriers. A notable deviation from the theoretical Richardson constant (140.0 Acm-2K-2 for n-Ge) on the conventional Richardson plot was alleviated by using the modified Richardson plot, which yielded the Richardson constant of 392.5 Acm-2K-2. Finally, we applied the theory of space-charge-limitedcurrent (SCLC) transport to the high forward bias region to find the density of localized defect states (Nt), which was determined to be 1.46 × 1012 eV-1cm-3.

중성자 조사된 SiC Schottky Diode의 온도 의존 특성 (Temperature Dependence of Neutron Irradiated SiC Schottky Diode)

  • 김성수;구상모
    • 한국전기전자재료학회논문지
    • /
    • 제27권10호
    • /
    • pp.618-622
    • /
    • 2014
  • The temperature dependent characteristics on the properties of SiC Schottky Diode has been investigated. In this study, the temperature dependent current-voltage characteristics of the SiC Schottky diode were measured in the range of 300 ~ 500 K. Divided into pre- and post- irradiated device was measured. The barrier height after irradiation device at 500 K increased 0.15 eV compared to 300 K, the barrier height of pre- neutron irradiated Schottky diode increased 0.07 eV. The effective barrier height after irradiation increased from 0.89 eV to 1.05 eV. And ideality factor of neutron irradiated Schottky diode at 500 K decreased 0.428 compared to 300 K, the ideality factor of pre- neutron irradiated Schottky diode decreased 0.354. Also, a slight positive shift in threshold voltage from 0.53 to 0.68 V. we analyzed the effective barrier height and ideality factor of SiC Schottky diode as function of temperature.

중국 진출 한국 제조기업의 현지 장애요인이 경영성과에 미치는 영향 연구 (A Study on the Factors Barrier Determining the Performance of Korean Manufacturing Firms in China)

  • 백은영;구종순
    • 통상정보연구
    • /
    • 제11권3호
    • /
    • pp.311-335
    • /
    • 2009
  • This study investigates the factors barrier the performance of Korean manufacturing firms in China. Also an empirical data use the field survey of Korean manufacturing firms in China. as a result, First, we find that employment-cost factor, that is rising labor costs, a change of occupation is an effect the performance of Korean manufacturing firms in China. Second, business beginning year and by 7 region factor is very significant on the performance of Korean FDI firms in china. And then, Korean corporate investment in China is a desirable form of long-term investment shall be determined. also we know that regions of China, differentiated investment approach is effective. finally, The result shows that FDI to China is need of the long term plan, and In actual use, these FDI should be applied flexibly in china business environment.

  • PDF

Temperature Dependent Current Transport Mechanism in Graphene/Germanium Schottky Barrier Diode

  • Khurelbaatar, Zagarzusem;Kil, Yeon-Ho;Shim, Kyu-Hwan;Cho, Hyunjin;Kim, Myung-Jong;Kim, Yong-Tae;Choi, Chel-Jong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제15권1호
    • /
    • pp.7-15
    • /
    • 2015
  • We have investigated electrical properties of graphene/Ge Schottky barrier diode (SBD) fabricated on Ge film epitaxially grown on Si substrate. When decreasing temperature, barrier height decreased and ideality factor increased, implying their strong temperature dependency. From the conventional Richardson plot, Richardson constant was much less than the theoretical value for n-type Ge. Assuming Gaussian distribution of Schottky barrier height with mean Schottky barrier height and standard deviation, Richardson constant extracted from the modified Richardson plot was comparable to the theoretical value for n-type Ge. Thus, the abnormal temperature dependent Schottky behavior of graphene/Ge SBD could be associated with a considerable deviation from the ideal thermionic emission caused by Schottky barrier inhomogeneities.

단편형 동기 릴럭턴스 전동기의 토크 및 열률 개선을 위한 회전자 설계 (Rotor Design of a Segmented Type Synchronous Reluctance Motor to Improve Torque and Power Factor)

  • 장석명;박병임;이성호;이중호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권6호
    • /
    • pp.263-272
    • /
    • 2001
  • The paper presents the design of a segmented type synchronous reluctance motor(SynRM) to increase its torque and power factor. The main feature of a segmented type synchronous reluctance motor is the flux barrier. Thus, the design process to find optimum value of various geometric parameters including flux barrier will be explained. Optimum value of each parameter is found where the d, q inductance difference and saliency ratio are maximized because these inductance characteristics are related to torque and power factor. Finite Element Analysis will be used to simulate motor characteristics. Analysis results of redesigned SynRM show higher saliency ratio over 10 and improved value of maximum power factor.

  • PDF

항암화학요법을 받는 암환자의 감염예방 행위와 장애요인의 관계 (The Relationship between Infection Prevention Behaviors and Barriers among Cancer Patients Undergoing Chemotherapy)

  • 이영란;권인수
    • 종양간호연구
    • /
    • 제7권2호
    • /
    • pp.150-161
    • /
    • 2007
  • Purpose: This study was to assess the degree of infection prevention behaviors at home, and a relationship between those behaviors and barrier factors among cancer patients undergoing chemotherapy. Method: The data were collected from 92 cancer patients who were undergoing chemotherapy with more than two kinds of immunosuppressive agents at G university hospital in J city from February 17 to April 4, 2003. The instruments were the infection prevention behavior scale developed by researchers and the barrier factor scale by Gu et al. (2003). The data were analysed using mean, standard deviation, t-test, ANOVA, and Pearson's correlation coefficient by SPSS program. Results: The mean score of the behaviors for infection prevention was 2.61 of 4. The highest score was on the subscale 'rest and exercise', and the lowest score was on the subscale 'monitoring sign and symptom of infection'. And a negative correlation(r= -.208, p= .023) was found between infection prevention behaviors and barrier factors. The barriers correlated to infection prevention behaviors were mainly 'no habits' and 'no interest'. Conclusion: It seems that the degree of the behaviors for infection prevention was not performed enough to prevent infection among cancer patients. And there was negative relationship between infection prevention behaviors and barriers. We suggest to develop a nursing intervention program to enhance infection prevention behaviors through reducing the barrier factors.

  • PDF

의료서비스에서 고객충성도에 대한 전환장벽의 조절효과 분석 (The Modifying Effect of Switching Barriers in Customer Loyalties in Medical Services)

  • 이선희;김현미;채유미
    • 보건행정학회지
    • /
    • 제17권3호
    • /
    • pp.68-86
    • /
    • 2007
  • This study was performed to explore the effect of customer satisfaction and switching barriers on customer royalties in medical services. 900 households, 1% sample were randomly selected from K city located in Kangwon province. Interview survey was performed with structured questionnaire for the entire people, 923 persons who experienced medical service utilization during one year before survey on time, september, 2002. In comparison of switching barriers by sociodemographic characteristics, lower income group and lower educated group showed the higher level of recognition level on availability of changing the service provider significantly. In terms of economic loss as one of switching barriers, the group of over aged 61, the lower income group and the lower educated group felt higher than other groups. Also, the time loss of switching barrier was recognized in 41-60 aged group and employee in service industry highly. For the perceived risk factor as another switching barrier, the high educated group showed the higher recognition level in performance risk and felt higher social risk than other groups. In analysis of customer satisfaction and loyalty levels by switching barrier components, the lower level of availability of changing the service provider and the higher level of recognition for economic and time loss, they showed the higher satisfaction and loyalty levels. In final step, multiple regression analysis showed the positive relationship between customer satisfaction, switching barrier and customer loyalties. Besides, the moderating effect of switching barrier in relationship between customer satisfaction and loyalties was significant and this results suggests that the influence of customer satisfaction to customer loyalties might be weakened in high level of recognition for switching barrier. In conclusion, perceived risk of economic and time loss as switching barrier is an important factor and should be considered in planning of marketing strategy carefully in terms of defensive marketing.