• Title/Summary/Keyword: Automatic Test Equipment

Search Result 189, Processing Time 0.024 seconds

Study on Practical Use of Air Vehicle Test Equipment(AVTE) for UAV Operation Support (무인항공기 운용 지원을 위한 비행체 점검장비 활용에 관한 연구)

  • Song, Yong-Ha;Go, Eun-kyoung;Kwon, Sang-Eun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.320-326
    • /
    • 2021
  • AVTE(Air Vehicle Test Equipment) is an equipment to inspect and check the status of on-board aircraft LRUs(Line Replacement Units) before and after flight for performing successful UAV(Unmanned Aerial Vehicle) missions. This paper suggests utilization of the AVTE as an operation support-equipment by implementing several critical functions for UAV-operation on the AVTE. The AVTE easily sets initialization(default) data and compensates for the installation and position errors of the LRUs which provide critical mission data and situation image with pilots without additional individual operation support-equipment. Major fault list and situation image data could be downloaded after flight using the AVTE in the event of UAV emergency situation or unusual occurrence on duty as well. We anticipate the suggested operational approach of the AVTE could dramatically reduce the cost and man power for design and manufacture of additional operation support equipment and effectively diminish workload of the operator.

Development of Interlocking Inspection Simulator for Electronic Interlocking System (전자연동장치를 위한 연동검사시스템의 개발)

  • Lee, Jae-Ho;Hwang, Jong-Gyu;Park, Young-Soo;Park, Gui-Tae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.2
    • /
    • pp.70-76
    • /
    • 2004
  • The purpose of interlocking system in railway is to prevent the route for a train being set up and its protecting signal cleared if there were already another, conflicting route set up and the protecting signal for that route cleared. Recently, conventional relays circuitry in industrial field is replaced to computer-based control systems according to the advance of computer and communication technology. Therefore, interlocking systems in railway field are rapidly changing from existing relay-based interlocking system to computer-based electronic ones that executes the vital interlocking logic to assure the safety train routes at trackside signaling equipment room using electronic circuits. So it is very important to verify the performance of developed electronic interlocking system by plentiful laboratory testing before actually application in the railway system. However the laboratory testing in the present state of railway signaling is preformed individually by manual, so very much test time and cost are required. To solve these problems, we are developed the simulator for automatic interlocking inspection in this research. This simulator is able to operate on general personal computer and has following beneficial functions : automatic test sheet generation for inspection, automatic inspection execution and et al. The experiments are executed to test the feasibility of the developed simulator the experimental results have good agreements with the anticipated ones.

Power-aware Test Framework for NoC(Network-on-Chip) (NoC에서의 저전력 테스트 구조)

  • Jung, Jun-Mo;Ahn, Byung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.437-443
    • /
    • 2007
  • In this paper, we propose the power-aware test framework for Network-on-Chip, which is based on embedded processor and on-chip network. First, the possibility of using embedded processor and on-chip network isintroduced and evaluated with benchmark system to test the other embeddedcores. And second, a new generation method of test pattern is presented to reduce the power consumption of on-chip network, which is called don't care mapping. The experimental results show that the embedded processor can be executed like the automatic test equipments, and the test time is reduced and the power consumption is reduced up to 8% at the communication components.

  • PDF

SCADA System for Semiconductor Equipment Condition Monitoring (반도체 장비상태 모니터링을 위한 SCADA 시스템 구현)

  • Lee, Youn Ji;Yun, Hak Jae;Park, Hyoeun;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.92-95
    • /
    • 2019
  • Automation control and the data for control of industrial equipment for the diagnosis and prediction is a key to success in the 4th industrial revolution. It increases process efficiency and productivity through data collection, realtime monitoring, and the data analysis. However, university and research environment are still suffering from logging the data in manual way, and we occasionally loss the equipment data logging due to the lack of automatic data logging system. State variable presents the current condition of the equipment operation which is closely related to process result, and it is valuable to monitor and analyze the data for the equipment health monitoring. In this paper, we demonstrate the collection of equipment state variable data via programmable logic controller (PLC) and the visualization of the collected data over the Web access supervisory control and data acquisition (SCADA). Test vehicle for the implementation of the suggested SCADA system is a relay switched physical vapor deposition system in the university environment.

New Challenges for Low Cost and High Speed RF ATE System (새로운 저가형 고속 RF 자동화 테스트 시스템)

  • Song, Ki-Jae;Lee, Ki-Soo;Park, Jongsoo;Lee, Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.8
    • /
    • pp.744-751
    • /
    • 2004
  • This paper presents the implementation of the low cost and high speed RF ATE(Automatic Test Equipment) system, which can be a reasonable solution for reducing the test cost of RF devices. This paper suggests high speed and precise measurement capabilities which are realized by the 16 independent RF ports with high speed switching time and high accuracy digitizer using the industry standard Versus module eXtensions for Instrument(VXI) General Purpose Interface Bus(GPIB) interfaces. Also, the system has the capabilities of quad-site test which can dramatically increase the device throughput. This paper concludes with the demonstration of the implemented ATE system through the setup of RF Power Amplifier Module(PAM), which is under the most competitive market situation.

Development of an automatic steam generator level control logic at low power (저 출력시 증기발생기 수위의 자동제어논리 개발)

  • Han, Jae-Bok;Jung, Si-Chae;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.601-604
    • /
    • 1996
  • It is well known that steam generator water level control at low power operation has many difficulties in a PWR (pressurized water reactor) nuclear power plant. The reverse process responses known as shrink and swell effects make it difficult to control the steam generator water level at low power. A new automatic control logic to remove the reverse process responses is proposed in this paper. It is implemented in PLC (programmable logic controller) and evaluated by using test equipment in Korea Atomic Energy Research Institute. The simulation test shows that the performance requirements is met at low power (below 15%). The water level control by new control logic is stabilized within 1% fluctuation from setpoint, while the water level by YGN 3 and 4 control logic is unstable with the periodic fluctuation of 25% magnitude at 5% power.

  • PDF

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Report on the improvement of the in vitro and specimen reception environment system (핵의학과 검체 접수 환경시스템의 개선사례 보고)

  • Kim, Jung In;Kang, Mi Ji;Kim, Na Kyung;Park, Ji Sol;Kwon, Won Hyun;Lee, Kyung Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.29-34
    • /
    • 2021
  • Purpose Sample reception environment system in nuclear medicine has not changed much compared to 20 years ago. When preparing sample for in vitro test, there was no significant change because the test was carried out by generating an own specimen from the parent specimen. In this study, We would like to introduce a method that automatically removes the sample cap using the automated decapper equipment and enables automatic reception at the same time. In addition, including a provisional reception system. Materials and Methods In 2019, it was intended to get a device that automatically removes the cap of a patient's blood sample. This equipment is the same as the equipment used in the Department of Laboratory Medicine (Vacuette Ⓡ Unicap Belt Decapper, Greiner bio-one, Austria). However, the purchase was delayed due to differences in tube size, budget, and space. In January 2020, we borrowed domestic automatic decapper equipment and modified it to suit our laboratory environment. After 9 months, we were able to introduce a system that automatically removes the lid of a patient's blood sample and at the same time automatically accepts the test. And, through the provisional reception system, it was possible to know the arrival of the specimen in a short time. Results With the use of an automatic decapper device, the sample cap was automatically removed, and the reception proceeded at the same time. So, it was very efficient at work because it shortened the sample preparation time by about 20 minutes. In addition, it was possible to prevent the examiner's musculoskeletal disorders caused by repeated wrist use. After using the provisional reception system, patients were able to be discharged quickly, and the number of phone calls to confirm the arrival of samples was reduced. Conclusion Most hospitals have about four employees in the nuclear medicine in vitro laboratory. It is effective to use automatic decapper equipment and a provisional reception system for organizations that perform work with the minimum number of personnel.

Application of Neural Inverse Modeling Scheme to Optimal Parameter Tuning of Filter Test Equipment

  • Kim, Sung-Ho;Han, Yun-Jong;Bae, Geum-Dong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.4 no.2
    • /
    • pp.172-175
    • /
    • 2004
  • Generally, the yield rate of semiconductors is the major factor that affects directly the price of semiconductors. For a high yield rate of semiconductors, the air inside clean room is needed to be purified and high efficient filters are used for this. The filter are made of super-fine fiber and certain pinholes can be easily produced on the filter's surface by inadvertent manufacturing. As these pinholes are not easily detected with the bare sight, these pinholes exert a negative impact to filtration performance of the filter. In this research, not only the automatic test equipment for detecting pinholes is proposed, but also inverse modeling scheme based on artificial neural network is applied for tuning of its important parameters.

Automatic real-name registration mark examiner research and development of special medical equipment for patient safety (환자 안전을 위한 특수의료장비의 검사자 실명제 자동 표식 등록 개발 연구)

  • Yoo, Se-Jong;Park, Jong-Bae;Kim, Jeong-Ho;Kim, Ki-Jin;Lim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.147-152
    • /
    • 2015
  • Through the inspector's real name to improve the quality of inspection is to show the design Radiological examination pursuant to the Ordinance of the Ministry of Health and Welfare for patient safety in the Image. However, the use of existing and in EMR, equipment within the handwriting input, the individual initial use has a problem. In this study, increasing the stability of the patient and the precise inspection, In order to increase the efficiency and convenience than the real-name system for quality control inspectors of medical equipment, Using the EMR and PACS developed and applied to evaluate the usefulness of automatic enrollment. Enter your information in the EMR, which was developed markers that inspectors use to compare the before and after images PACS satisfaction. Convenience than using traditional, consistency, the entry of the missing were higher as a statistically significant difference. A test strip automatic enrollment programs are developed in this study. You can increase the stability of the patient by checking the image to show the real tester, we expect the quality of care would be improved.