• Title/Summary/Keyword: AtPIN3

Search Result 464, Processing Time 0.023 seconds

Sliding Wear and Friction Behavior of Electro-Pressure Sintered Fe-Ni and Co-Fe-Ni Compacts (Fe-Ni, Co-Fe-Ni 소결체의 미끄럼 마찰 및 마멸거동)

  • Kwon Yong Jin;Kim Tai-Woung;Kim Yong-Suk
    • Korean Journal of Materials Research
    • /
    • v.15 no.4
    • /
    • pp.224-232
    • /
    • 2005
  • Dry sliding wear behavior of electro-pressure sintered Fe-Ni and Co-Fe-Ni compacts was investigated. Pin-on-disk wear tests were performed on the sintered Fe-Ni, Co-Fe-Ni disk specimens against alumina $(Al_2O_3)$ and silica $(SiO_2)$ ball counterparts at various loads ranging from 3N to 12N. A constant sliding speed of 0.1m/sec was employed. Wear rate was calculated by dividing the weight loss measured after the test by specific gravity and sliding distance. Worn surfaces and cross sections of them were examined by a scanning electron microscopy, and wear mechanism of the compacts was investigated. Wear characteristics of the compacts were discussed as a function of composition of the compacts. Relationship between the wear rate and mechancial properties of the compact was explored, and effects of the oxide layer that was formed on wearing surface of the compacts on the wear were also studied.

Ceramic-Ceramic Wear of Zirconia/Alumina Composites for the Application of Total Hip Replacement (인공 고관절 골두용 세라믹 복합재료에 대한 세라믹-세라믹 접촉 마멸 특성 분석)

  • Lee Kwon-Yong;Kim Hwan;Kim Dae-Jun;Lee Myong-Hyon;Seo Won-Seon
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.216-220
    • /
    • 2005
  • The sliding wear behaviors of three different compositions of novel low temperature degradation-free zirconia/alumina (LTD-free Z/A) composites were examined in a ceramic-ceramic contact pair. The wear tests were performed by using a pin-on-disk type wear tester in a linear reciprocal sliding motion with a line contact in both dry and bovine serum lubricated conditions at room temperature. From the results of dry sliding wear tests, Z/A#1((5.3Y, 4.6Nb)-TZP/80 $vol\%Al_2O_3$) showed the best wear resistance among three kinds of LTD-free Z/A composites. For the bovine serum lubricated sliding wear tests, wear was too little to be measured for all kinds of Z/A composites. These novel LTD-free Z/A composites having excellent wear resistance demonstrated a potential as the alternative materials for the ceramic-ceramic contact pairs of femoral head and acetabular liner in total hip replacement.

Characterization of Kombucha Beverages Fermented with Various Teas and Tea Fungus

  • Lee, Sam-Pin;Kim, Chan-Shick
    • Preventive Nutrition and Food Science
    • /
    • v.5 no.3
    • /
    • pp.165-169
    • /
    • 2000
  • Kombucha beverages were made from sweetened tea by Oriental, European and Tibetan tea fungus starters. The hot water extracts o green tea, black tea, Gugija and Omija were mixed with white and/or brown sugar, and were fermented under a static culture at 3$0^{\circ}C$. Titrable acidity, pH, color and cellulose production in kombucha beverages were evaluated. All tea fungus starters showed a higher acid production in green/black tea extracts rather than Gugija and Omija extracts. In green/black tea extracts Oriental tea fungus produced a kombucha beverage with a higher titrable acidity and lower pH than those of European and Tibetan tea fungus starters. By the static fermentation of green/black tea extract for 18 days, Oriental, Tibetan and European tea fungus starters produced cellulose pellicles of 0.43g, 0.16g, and 0.19 g (dry weight) on the top in the culture, respectively. As a mother starter, the cellulose pellicle was more efficient in acid production compared with tea fungus broth. Oriental/Tibetan mixed tea fungus showed the best acid production in the green/black tea extract supplemented with brown sugar.

  • PDF

Sliding Wear and Friction Behavior of Electro-Pressure Sintered Co-Fe and Co-Ni Compacts (통전가압 소결된 Co-Fe, Co-Ni 소결체의 미끄럼 마찰 및 마멸거동)

  • Kwon Yong Jin;Kim Tai-Woung;Kim Yong-Suk
    • Journal of Powder Materials
    • /
    • v.11 no.6 s.47
    • /
    • pp.451-461
    • /
    • 2004
  • Dry sliding wear behavior of electro-pressure sintered Co-Fe and Co-Ni compacts was investigated. Pin-on-disk wear tests were performed on the sintered Co-Fe, Co-Ni disks against alumina $(Al_2O_3)$ and silica $(SiO_2)$ balls at various loads ranging from 3N to 12N. A constant sliding speed of 0.1m/sec was employed. Wear rate was calculated by dividing the weight loss of a specimen by the measured specific gravity and sliding dis-tance. Worn surfaces and cross-sections of the specimens were examined using an SEM and EDS to investigate wear mechanism of the compacts. The wear behavior of the compacts were discussed as a function of their com-position. Effects of mechancial properties of the compact as well as oxide layers formed on wearing surface on the wear were also discussed.

Double Square Patch Antenna with Inductive Bridges for WLAN Dual-Band (인덕티브 브릿지를 가진 WLAN 이중 대역 이중 사각 패치 안테나)

  • Yang, Chan-Woo;Jung, Chang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2615-2618
    • /
    • 2009
  • Double rectangular patch with 4-bridges is investigated for solution of IEEE 802.11b/g (2.4 GHz) and 802.11a (5.5 GHz). Rectangular patch for 5.5 GHz frequency band is printed on the PCB substrate and connected to another rectangular patch for 2.4 GHz frequency band with 4-bridges to obtain dual band operation in an antenna element. 4-bridges can modify the desired frequency band from its original frequency band by changing its width. Gain of 2.4 GHz patch is 5 dBi and 5.5 GHz patch is 3.7 dBi at ${\theta}=0^{\circ}$.

Traumatic Pseudoaneurysm of the Superficial Temporal Artery due to Gardner Traction

  • Lee, Hyun-Seok;Jo, Kwang-Wook;Lee, Sun-Ho;Eoh, Whan
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.3
    • /
    • pp.291-293
    • /
    • 2010
  • We report a case of pseudoaneurysm of the parietal division of the superficial temporal artery (STA) secondary to iatrogenic head injury due to Gardner traction. A 54-year-old man presented with a pulsatile, cystic, and painless mass in the right anterior temporal region which developed three weeks after head fixation via Gardner traction. At the time of discovery, the mass was 10 mm in diameter, compressible and disappeared after manual compression of the proximal STA. A bruit was audible over the mass, which was thought to be a pseudoaneurysm. A computed tomography angiogram (CTA) showed a pseudoaneurysm of the parietal division of the right ST A. The tip of the pseudoaneurysm was thrombosed and was both red and tender. The pseudoaneurysm was thought to be filled with infected thrombus, and the mass was resected with ligation of the proximal and distal ends of the STA. A pseudoaneurysm of the STA should be suspected when there is a history of possible vessel injury, such as a history of head-pin fixation, and when a patient presents with a pulsatile, cystic mass near the temple. Pseudoaneurysms can be successfully treated by excision.

A 3.1 to 5 GHz CMOS Transceiver for DS-UWB Systems

  • Park, Bong-Hyuk;Lee, Kyung-Ai;Hong, Song-Cheol;Choi, Sang-Sung
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.421-429
    • /
    • 2007
  • This paper presents a direct-conversion CMOS transceiver for fully digital DS-UWB systems. The transceiver includes all of the radio building blocks, such as a T/R switch, a low noise amplifier, an I/Q demodulator, a low pass filter, a variable gain amplifier as a receiver, the same receiver blocks as a transmitter including a phase-locked loop (PLL), and a voltage controlled oscillator (VCO). A single-ended-to-differential converter is implemented in the down-conversion mixer and a differential-to-single-ended converter is implemented in the driver amplifier stage. The chip is fabricated on a 9.0 $mm^2$ die using standard 0.18 ${\mu}m$ CMOS technology and a 64-pin MicroLead Frame package. Experimental results show the total current consumption is 143 mA including the PLL and VCO. The chip has a 3.5 dB receiver gain flatness at the 660 MHz bandwidth. These results indicate that the architecture and circuits are adaptable to the implementation of a wideband, low-power, and high-speed wireless personal area network.

  • PDF

Wideband Frequency Tunable Metamaterial Absorber Using Switchable Ground Plane (그라운드를 전환하여 주파수를 가변할 수 있는 광대역 메타물질 흡수체)

  • Jeong, Heijun;Lim, Sungjoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.241-246
    • /
    • 2018
  • In this study, we proposed a wideband frequency tunable metamaterial absorber using a switchable ground plane (SGP). We proposed two fire retardant or flame resistant 4 (FR4) substrate structures for the SGP. An SGP is placed at the middle layer, between the top pattern and the bottom ground plane. The SGP can either be made ground or reactive, by switching the PIN diode ON/OFF. As the frequency is determined by the substrate thickness, the frequency can be switched from the SGP. The proposed absorber is demonstrated by full-wave simulations and measurements. When the SGP is turned on, an absorptivity higher than 90% is achieved from 3.5 GHz to 11 GHz. When the SGP is turned off, an absorptivity higher than 90 % is achieved from 1.7 GHz to 5.2 GHz.

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.8
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.