• Title/Summary/Keyword: Artifact display

Search Result 39, Processing Time 0.027 seconds

3D Restoration of Cultural Remains for Exhibiting Augmented Reality (증강현실 활용 전시를 위한 문화 유물 디지털 3D 복원)

  • Zheng, mei-ying;Ryu, Seuc-Ho
    • Journal of Digital Convergence
    • /
    • v.15 no.12
    • /
    • pp.549-554
    • /
    • 2017
  • In recent years, as the importance of history has increased through various social issues, media, and journalists in Korea, it has led to the value of 'right history' and 'teaching history that is right. History of a country is also a core asset in a country 's cultural contents industry, and historical relics are important to prove its value. As the interest in the historical and cultural heritage has increased, researches to develop it as cultural contents by restoring it as information and communication technology such as multimedia and virtual reality are active. In this paper, we propose convergence device and contents that can provide rich experience and various learning opportunities in artifact experience through restoration of artifacts using augmented reality. The study on the application effect of educational game contents which can add fun can be continued.

The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images (PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가)

  • Han, Dong Chan;Hong, Gun Chul;Choi, Choon ki;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.90-94
    • /
    • 2013
  • Purpose: In the PET/CT images, various artifacts cause degradation of the quantitative assessment. Most hotspot generated by radiopharmaceutical injection errors cause an artifact and degrade the quality of the images as well as the accuracy of the quantitative evaluation. The purpose of this study is to assess effectiveness of the elimination of the hotspot at the injection sites using shifting the center of DFOV (Display Field of View, DFOV) method and evaluate the quantitative evaluation of result. Materials and Methods: GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) and 1994 NEMA phantom were used for imaging acquisition. Phantom was filled with 0.005 MBq/mL of $^{18}F-FDG$. A hotspot was artificially placed on the outside of the phantom. The ratio of hotspot area activity to background area activity was regulated as 200:1. After image acquisition with routine protocol, all of the images were reconstructed using the shifting the center of DFOV method that wasn't overlapped with hotspot. Those images obtained before and after applying the shifting reconstruction method were compared. ROIs (Region Of Interests) were set in the hotspot areas, meanSUVs and standard deviations were calculated. Percentage differences were calculated with those meanSUVs and standard deviations. The evaluation on the effects of the shifting reconstruction method was done by comparison of the meanSUVs and the standard deviations, which were calculated for background areas unaffected by hotspot. Results: In the areas of unaffected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.67{\pm}0.06g/mL$ and $0.65{\pm}0.06g/mL$, respectively. In the artifact areas affected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were $0.32{\pm}0.08g/mL$ and $0.56{\pm}0.12g/mL$, respectively. The percentage differences of the area adjacent to the hotspot and the area distant from the hotspot were 65.3% and 97.4%, respectively. Conclusion: In the PET/CT images, meanSUV was improved by 32.1% when the effect of artifact was removed with application of the shifting the center of DFOV methode. In other areas unaffected by artifacts, meanSUVs were not significantly different after applying DFOV center shift method. As shown in the result, adverse effects of hotspot made by swelling in the injection site can be reduced by applying DFOV center shift method. Therefore, DFOV center shift method can be applied for the more precise quantitative evaluation, and contribute to the increase of the diagnostic value of the images.

  • PDF

The Evaluation of the Difference of the SUV Caused by DFOV Change in PET/CT (PET/CT 검사에서 확대된 표시시야가 표준섭취계수에 미치는 영향 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.13-20
    • /
    • 2011
  • Purpose: The limited FOV(Field of View) of CT (Computed Tomography) can cause truncation artifact at external DFOV (Display Field of View) in PET/CT image. In our study, we measured the difference of SUV and compared the influence affecting to the image reconstructed with the extended DFOV. Materials and Methods: NEMA 1994 PET Phantom was filled with $^{18}F$(FDG) of 5.3 kBq/mL and placed at the center of FOV. Phantom images were acquired through emission scan. Shift the phantom's location to the external edge of DFOV and images were acquired with same method. All of acquired data through each experiment were reconstructed with same method, DFOV was applied 50 cm and 70 cm respectively. Then ROI was set up on the emission image, performed the comparative analysis SUV. In the clinical test, patient group shown truncation artifact was selected. ROI was set up at the liver of patient's image and performed the comparative analysis SUV according to the change of DFOV. Results: The pixel size was increase from 3.91 mm to 5.47 mm according to the DFOV increment in the centered location phantom study. When extended DFOV was applied, $_{max}SUV$ of ROI was decreased from 1.49 to 1.35. In case of shifted the center of phantom location study, $_{max}SUV$ was decreased from 1.30 to 1.20. The $_{max}SUV$ was 1.51 at the truncated region in the extended DFOV. The difference of the $_{max}SUV$ was 25.9% higher at the outside of the truncated region than inside. When the extended DFOV was applied, $_{max}SUV$ was decreased from 3.38 to 3.13. Conclusion: When the extended DFOV was applied, $_{max}SUV$ decreasing phenomenon can cause pixel to pixel noise by increasing of pixel size. In this reason, $_{max}SUV$ was underestimated. Therefore, We should consider the underestimation of quantitative result in the whole image plane in case of patient study applied extended DFOV protocol. Consequently, the result of the quantitative analysis may show more higher than inside at the truncated region.

  • PDF

Multisensory based AR System for Education of Cultural Heritage

  • Jeong, Eunsol;Oh, Jeong-eun;Won, Haeyeon;Yu, Jeongmin
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.11
    • /
    • pp.61-69
    • /
    • 2019
  • In this paper, we propose a multisensory(i.e., visual-auditory-tactile) based AR system for the education of cultural heritage. The proposed system provides a multisensory interaction by designing a user to experience with a 3D printed artifact which is mapped by a virtual 3D content of digital heritage. Compared with the existing systems of cultural heritage education based on augmented reality(AR) technology, this system focused on not only providing learning experience via a sense of visual and auditory, but also a sense of tactile. Furthermore, since this systems mainly provided the direct interactions using a 3D printed model, it gives a higher degree of realism than existing system that use touch or click motions on a 2D display of mobile phones and tablets. According to a result of user testing, we concluded that the proposed system delivered the excellent presence and learning flow to users. Particularly, from the usability evaluation, a 3D printed target artifact which is similar in shape to original heritage artifact, achieved the highest scores among the various tested targets.

Real-Time Continuous-Scale Image Interpolation with Directional Smoothing (방향적응적인 연속 비율 실시간 영상 보간 방식 -방향별 가우시안 필터를 사용한 연속 비율 지원 영상 보간 필터-)

  • Yoo, Yoon-Jong;Jun, Sin-Young;Maik, Vivek;Paik, Joon-Ki
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.615-619
    • /
    • 2009
  • A real-time, continuous-scale image interpolation method is proposed based on bi-linear interpolation with directionally adaptive low-pass filtering. The proposed algorithm has been optimized for hardware implementation. The original bi-linear interpolation method has blocking artifact. The proposed algorithm solves this problem using directionally adaptive low-pass filtering. It can also solve the severely problem by selection choosing low-pass filter coefficients. Therefore the proposed interpolation algorithm can realize a high-quality image scaler for various imaging systems, such as digital camera, CCTV and digital flat panel display, to name a few.

  • PDF

Reconstructed image quality enhancement by an improved pickup model in computational integral imaging (컴퓨터 집적 영상 기술에서 픽업 모델 개선에 의한 복원 화질 개선 방법)

  • Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1598-1603
    • /
    • 2011
  • This paper describes an enhancement method for a computational pickup model. The conventional computational pickup model utilizes the ray-trace model and the pinhole model. The conventional model is very useful, however, it suffers from quality degradation of reconstructed images at long distances. To overcome the problem, we propose an accurate pickup model. The proposed model includes integration of the rays incoming to a sensor that generates a pixel, resulting in robustness on the Aliasing artifact. To show the effectiveness of the proposed method, experimental results are carried out. The results indicated that the proposed method is superior to the conventional method.

Analysis of 3D reconstructed images based on signal model of plane-based computational integral imaging reconstruction technique (평면기반 컴퓨터 집적 영상 복원 기술의 신호모델을 이용한 3D 복원 영상 분석)

  • Shin, Dong-Hak;Yoo, Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.1
    • /
    • pp.121-126
    • /
    • 2009
  • Plane-based computational integral imaging (CIIR) provides the reconstruction of depth-dependent 3D plane images. However, it has problem degrading the resolution of reconstructed images due to the artifact noise according to the depth. In this paper, to overcome this problem, a signal model for plane-based CIIR is explain. Also the compensation process is introduced to remove the noise caused from CIIR. Computational experiments show that we analyze the characteristics of noise in the reconstructed image of 2D Gaussian image and the high-resolution images can be obtained by using the compensation process.

금속유물의 부식화합물(I)-철제유물을 중심으로

  • Lee, O-Hui
    • 보존과학연구
    • /
    • s.6
    • /
    • pp.48-57
    • /
    • 1985
  • This report described the corrosion structure of excavated iron artifacts in terms of simple model based on the knowledge of the corrosion process. (Fig.1)(Table 1,2)In storing the objects, there are basically three ways in which they either break in wedges, flakes and dish-shaped flakes. Completely mineralized objects or those with only a small iron core tend to break into wedges and more solid objects either split small dish-shaped flakes or large flat ones.(Fig. 2,3,4)There are two ways, therefore, to prevent this from happening. One is to keep the artifacts rigorously dried in Silica-gel, never allowing the relative humidity to rise. This is feasible which the artifacts are in store but causes great difficulty if they are wanted for museum display. Because they still contain $ FeCl _2$ they are always at risk ; they contain the seeds of their own destruction. The other alternative is to use of washing process to dissolve out the $ FeCl _2$. In this connection, many different methods to stabilize the artifact have been employed; boiling iron in frequent changes of water, soaking in Na-sesquicarbonate solution, soaking in alkaline Na-sulphite solution. In this report, introduced the alkaline sulphite method by the N.A. North and C.Pearson.Finally, Let me extend my thanks to Ancient Monument Lab., Museum of London Conservation Lab., British Museum Conservation Div. and National Maritime Museum Conservation Lab. who have helped me and made many valuable suggestions.

  • PDF

A Study On Antialiasing Based On Morphological Pixel Structure (형태학적 픽셀구조에 기반한 앤티에얼리아싱에 관한 연구)

  • Lee, Yong-Jae
    • Journal of Korea Game Society
    • /
    • v.3 no.1
    • /
    • pp.86-93
    • /
    • 2003
  • In this paper, we propose a new antialiasing method using filtering technique which is base on morphological pixel structure Aliasing occurs along the edge of lines and polygons. This undesirable effect happens because there are not enough pixels available on a typical monitor to properly display mathematically smooth lines and polygon edges. Aliasing can be very distracting. In a typical graphic scene, aliasing artifact will be visible along the edges of all objects that greatly diminish of realism. The proposed antialiasing method attempts to smooth extreme jagged contour lines and edges by properly handling pixel's structure, surface type and adjusting the pixel color according to the amount of pixel coverage. Next, we use filtering technique considering morphological pixel structure. Experimental results have shown that the propose algorithm achieves better performance in reducing noise for antialiasing. The method will be widely applied to basic antialiasing technique for computer graphic applications.

  • PDF

Usefulness of DFOV Changes in Pediatric PET/CT Image Reconstruction (PET/CT에서 소아환자 영상 재구성 시DFOV 변화의 유용성)

  • Choi, Sung-Wook;Choi, Choon-Ki;Lee, Kyoo-Bok;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.171-175
    • /
    • 2008
  • Purpose: There have been something difficulties in locating focuses and quantitative analysis in case of pediatric patients because of the relatively small body compared to adults. This author of this study, therefore, evaluated the usefulness of DFOV (Display Field Of View) according to its changes in PET/CT image reconstruction by means of the phantom experiment and pediatric patients examination. Materials & Methods: 0.023 MBq/cc of $^{18}F$-FDG was put into the uniform NU2-94 phantom, and then emission scan was acquired for 10 minutes. For reconstruction, DFOV values were changed to 50, 45, 40, 35, 30, and 25 cm respectively. As for patient images, 20 patients who were diagnosed as the one or suspicion of the children tumor are targeted from Oct 2007 to Jan 2008. For image reconstruction, 50 cm was the basis of DFOV, and the value was adjusted to DFOV 45 cm to 25 cm respectively. In the phantom and the reconstruction image of pediatric patients, the changes in pixel size and $SUV_{max}$ according to DFOV changes were analyzed. Results: As DFOV decreased to 50, 45, 40, 35, 30, and 25 cm by means of the phantom, the pixel size was changed to 3.906, 3.515, 3.125, 2.734, 2.343, and 1.953 mm respectively. Besides, as a result of reconstruction DFOV in images of pediatric patients to 50, to 25 cm, the different values of $SUV_{max}$ are shown as 3.3, 7.3, 12, 14, 18% and 2.6, 4.3, 5.0, 7.0, 10.0% on respectively when 50 cm was the standard. Conclusion: In $SUV_{max}$ using the phantom, as DFOV decreased every 5 cm, the mean value gradually increased. With 50 cm as the standard, the increase rates were 3.7, 6.5, 11.2, 19.5, and 32.1% respectively. As for pediatric patients image too, as DFOV decreased, the rates increased as in the phantom experiment. In image reconstruction, since DFOV decrease regardless of matrix size change reduced the pixel size, the image quality can be improved. This would be more useful than reconstruction and enlarge images of pediatric patients in the same way of examining adults. However, when the value of 35 cm DFOV was applied, this may result in truncated artifact, and thus the application should be properly controlled. Change of DFOV may produce better image for pediatric patients, but changes of SUV values according to DFOV change should be considered in reading.

  • PDF